The text of a manual · part 36 of 42
DS/DD Series B Enhanced Bar Code Decoders User Manual (Bulletin 2755), pages 312 to 318
Pages 312 to 318 of 361: C - Transmission Check; D - Setting Up Terminals
The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 2755-DD and Allen-Bradley 2755-DS
Page 312
The decoder can generate three types of transmission checks:
• Longitudinal Redundancy Check A byte developed by an exclusive OR of all bytes in a message.
• Checksum, Most Significant Byte First Sixteen bit sum of all the bytes in a message with the most significant byte transmitted first.
• Checksum, Least Significant Byte First Sixteen bit sum of all the bytes in a message with the least significant byte transmitted first. The following example illustrates a transmission check. The message contains the following data: Start Character = * Label Delimiter = $ End of Message = CR LF Symbol Data = ABC The message transmits in this sequence: * $ A B C $ $ CR LF TRANSMISSION CHECK The table below shows transmission checks for the message. Transmission Check
LRC Check Checksum MSB Checksum LSB
ASCII Character * $ A B C $ $ CR LF I SOH s s SOH
Hex Value 2A 24 41 42 43 24 24 OD OA 49 01 73 73 01
Binary Value 0010 1010 0010 0100 0100 0001 0100 0010 0100 0011 0010 0100 0010 0100 0000 1101 0000 1010 0100 1001 0000 0001 0111 0011 0111 0011 0000 0001
The sum of all bytes in the message is 173 Hex. Checksums are transmitted in a sixteen bit format. The value 01 Hex is equivalent to the ASCII control code SOH, 73 Hex is equivalent to the ASCII character “s”.
Publication 2755-833
Page 313
Setting Up Terminals Appendix Objectives
This appendix provides instructions on how to setup and connect the following terminals to the AUX port of the NEMA Type 1 or Type 4 decoder. • Lear Siegler ADM 3E • DEC VT100 • 1784-T45 • 1771-T1, -T2, -T3
Connecting Terminal to AUX Port on NEMA Type 1 Decoder 1 14
Pin 1
GND
Chassis Ground
2
TD
Transmit Data carries data from terminal to decoder. (input to decoder)
3
RD
Receive Data carries data from decoder to terminal. (Output from decoder)
7
SIG GND
Signal Ground
15
AUX Terminal Selector +
AUX Terminal Selector. Determines whether the AUX terminal is used for configuration or manual data entry. To use the AUX terminal for manual data entry, tie pin 15 to 16. To use the AUX terminal for configuration, leave pins 15 and 16 open.
16
AUX Terminal Selector –
Connect to pin 15 to use the AUX terminal for manual data entry functions. When connected to 15, you cannot access the configuration menus.
17 25
IN8+ IN8–
Auto Load Input. You can connect a normally opened (N.O.) contact between pins 17 and 25. Close the contacts to activate the AutoLoad Function. See Chapter 6 and Appendix H.
AUX PORT (female) Connector
25 13
Connecting Terminal to AUX Port of NEMA Type 4 Decoder
Pin
Abb. GND
Chassis Ground
B
TD
Transmit Data carries data from terminal to decoder (Input to decoder).
C
RD
Receive Data carries data from decoder to terminal (Output from decoder).
D
SIG GND
Signal Ground
G
AUX Terminal Selector +
AUX Terminal Selector. Determines whether the AUX terminal is used for configuration or manual data entry. To use the AUX terminal for manual data entry, tie pin G to H. To use the AUX terminal for configuration, leave pins G and H open.
H
AUX Terminal Selector –
Connect to pin G to use the AUX terminal for manual data entry functions. When connected to G, you cannot access the configuration menus.
K L
IN8+ IN8–
Auto Load Input. You can connect a normally opened (N.O.) contact between pins K and L. Close the contacts to activate the AutoLoad Function. See Chapter 6 and Appendix H.
M L J H
N
U T
V
A B P R
S G
F
C D
E
Function
A
AUX PORT (male) Connector
K
Function
Abb.
Publication 2755-833
Page 314
D–2
Setting Up Terminals
Lear Siegler ADM 3E Terminal
Follow these steps if using a Lear Siegler ADM 3E terminal: 1. Construct a cable to connect the terminal to the decoder. Use a Belden 8303, Alpha 45123, or equivalent type of cable. Use the following connector pinouts: Male 19-pin NEMA Type 4 or Female 25-pin D Shell Connector
Decoder
NEMA Type 4
NEMA Type 1
C B D
2 3 7
25-pin male
Transmit Data Receive Data Signal Ground
2 3 7
Terminal
Note: Connect shield to shell of cable connectors at both ends.
2. Plug terminal into power supply. 3. Power on terminal. 4. Press [Shift] [SETUP] to enter setup mode. 5. Use the arrow keys to set the following parameters on the terminal:
• • • • • •
Full Duplex (FDX) 9600 Baud Rate 8 Data Bits per Character No Parity XON/XOFF Flow Control or Handshake Blinking Block Cursor
6. To save the selected parameters, press [Ctrl] [S]. 7. Exit setup mode by pressing [Shift] [SETUP]. 8. You are now ready to configure the decoder. See Chapter 5.
Publication 2755-833
Page 315
Setting Up Terminals
DEC VT100 Terminal
D–3
Follow these steps if using a DEC VT100 terminal: 1. Construct a cable to connect the VT100 to the decoder. Use a Belden 8303, Alpha 45123, or equivalent type of cable. Use the following connector pinouts: Male 19-pin NEMA Type 4 or Female 25-pin D Shell Connector
Decoder
NEMA Type 4
NEMA Type 1
C B D
2 3 7
25-pin Female
Transmit Data Receive Data Signal Ground
3 2 7
Terminal
Note: Connect shield to shell of cable connectors at both ends.
2. Plug terminal into power supply. 3. Power on terminal. 4. Enter Set-Up B on terminal. The following figure shows one setup. SETUP B TO EXIT PRESS ”SET-UP”
1 0101
2 0011
1 . . 01
3 0000
4 0010
2 . . 11 Cursor Block Screen Dark Don’t Care Don’t Care
T SPEED 9600
R SPEED 9600
3 . 00 . XON/XOFF ON ANSI Don’t Care Don’t Care
4 . 010 Don’t Care New Line Off Wrap Off Don’t Care
60 Hz 8 Bits Parity Off Don’t Care
5. You are now ready to configure the decoder. See Chapter 5.
Publication 2755-833
Page 316
D–4
Setting Up Terminals
Allen-Bradley 1784-T45 or T47 Programming Terminal
Follow these steps if using an Allen-Bradley 1784-T45 or -T47 computer: 1. Construct a cable to connect the terminal to the decoder. Use a Belden 8303, Alpha 45123, or equivalent type of cable. Use the following connector pinouts: Male 19-pin NEMA Type 4 or Female 25-pin D Shell Connector
Decoder
NEMA Type 4
NEMA Type 1
C B D
2 3 7
25-pin Female
Transmit Data Receive Data Signal Ground
. Note: Connect shield to shell of cable connectors at both ends.
2 3 4 CTS 5 RTS 6 DSR 7 8 CD 20 DTR
Terminal
2. Power on the terminal. The switch is located on the left side of the unit. The terminal will beep once, and then test itself. When the test is complete, a message appears. The last line should indicate that all tests have passed. 3. Press [CTRL][ALT][CMD] key sequence to display the system Main Menu (Press the [CMD] key while holding down both the [ALT] and [CTRL] keys. 4. Set the T45 terminal emulation to the following settings (Refer to the terminal documentation for additional information):
• • • • •
F1 DGC D200 Terminal F2 Modem = External F3 Flow Control = On F4 Duplex = Full F6 Print = Off
5. Set the COM1 parameters to:
• • • • •
F1 Baud Rate = 9600 F2 Parity = None F3 Data Bits = 8 F4 Stop Bits = 1 F5 Type = Standard PC Compatible Com
Note: If using an internal modem, disable it using the MODE command.
Publication 2755-833
Page 317
Setting Up Terminals
D–5
6. When the Select CRT Type menu appears, select Data General DT100 emulation. 7. You are now ready to configure the decoder. See Chapter 5.
Allen-Bradley 1770-T1, -T2, -T3 Terminals
Follow these steps if using an Allen-Bradley 1770-T1, -T2, or -T3 terminal: 1. Construct a cable to connect the decoder to Channel B of the terminal. Use a Belden 8303, Alpha 45123, or equivalent type of cable. Use the following connector pinouts: Male 19-pin NEMA Type 4 or Female 25-pin D Shell Connector NEMA Type 4
Decoder
C B D
25-pin Male
NEMA Type 1
2 3 7
Transmit Data Receive Data Signal Ground
. .
2 3 7 18 25
Terminal
Note: Connect shield to shell of cable connectors at both ends.
2. Plug terminal into power supply. 3. Install the alphanumeric keytop overlay on the terminal keyboard. 4. Power on terminal. Enter 12 to select alphanumeric. 5. Select Alphanumeric Mode and set the following parameters (Refer to your terminal documentation for additional information): Baud Rate Parity = Stop Bits = Channel Config. = Duplex = Channel C = Cursor = Auto Line Feed after Return = Control Code Display =
9600 No 1 B IN/OUT Full On or Off On Off Off
6. You are now ready to configure the decoder. See Chapter 5. Note: Because there is no flow control with the 1770-T1, -T2, or -T3 terminals, the Series B Revision A decoder could transmit data too quickly. This caused the terminal to display garbled characters or lock up. To resolve that problem, the Revision B decoder sends data in smaller bursts to these terminals.
Publication 2755-833
Page 318
D–6
Setting Up Terminals
2708-DH5 Attended Workstations
Follow these steps if using one of the Allen-Bradley 2708-DH5 Attended Workstations: 1. Construct a cable to connect the decoder to the COM1 port of the 2708-DH5 terminal. Use a Belden 8303, Alpha 45123, or equivalent type of cable. Use the following connector pinouts: Male 19-pin NEMA Type 4 or Female 25-pin D Shell Connector
Decoder
NEMA Type 4
NEMA Type 1
C B D
2 3 7
9-pin Female
3 2 5
Terminal
2. Plug terminal into power supply. 3. Power on terminal. 4. Select Network Menu (option 1) and set the following parameters: Terminal Number = 0 Terminal Type = Normal
The rest of the network parameters are not applicable. 5. Select Comm Port Menu (option 2) and set the following parameters: Comm Mode Comm Baud Rate = Comm Data Bits = Comm Parity = Comm Stop Bits = Comm CRLF = Comm Echo = Comm Handshake =
XON/XOFF 9600 8 None 1 Disabled Disabled Disabled
The rest of the parameters are not applicable. 6. You are now ready to configure the decoder. See Chapter 5.
Publication 2755-833