DS/DD Series B Enhanced Bar Code Decoders User Manual (Bulletin 2755): A - Decoder Configuration Addresses

Pages 294 to 308 of 361, from DS/DD Series B Enhanced Bar Code Decoders User Manual (Bulletin 2755)

The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Allen-Bradley 2755-DD and Allen-Bradley 2755-DS

Page 294 read from a scan by OCR; it may hold reading errors

Appendix A

Decoder Configuration

Addresses . . Number of Acceptable Values PCCC Address Configuration Parameter Bytes (Default in bold) 300 Reserved 1 3C1 AUX Terminal 1 0=No Enable Keyboard Entry 1 = Yes 2 = No Read 3C2 AUX Terminal 1 0=No Confirm Entry 1 = Yes 303 AUX Terminal 1 0 = Unformatted Aux Data Format 1 = Host Format 3C4 AUX Terminal 1 ASCII 0 - 255, 255 = None Rubout Char for Keyboard Entry 8=BS 305 Echo Keyboard Data 1 0=No 1 = Yes 3C6 Size of Display 1 10-80 3C7 AUX Terminal, Source Identifier String Length 1 0-4, 0 = Empty String 4 4 characters 3CC AUX Terminal, Default Prompt Message String Length 1 0-20, 0 = Empty String 20 20 characters 3E1 Scroll LCD 1 0=No 1 = Yes 3E2 Scanner B Trigger Source 1 0 = Port A (Coordinated1) 1 = Port B (Ind., Package Det) 2 = Port B (Ind., Host Control) 3 = Port B (Coordinated2) 3E3 Reserved 1 Ignored 3E4 Scanner B Trigger Timeout 2 0, 10 ... 9999 3E6 Scanner B - Source Identifier String Length 1 0-4, 0 = Empty String 4 4 characters 3EB Enable UPC-A Supplement 1 0=No 1=2Char 2 =5 Char 3 =2or5 Char 4 = Auto 3EC Enable UPC-E Supplement 1 0=No 1=2Char 2 =5 Char 3 =2or5 Char 4 = Auto 3ED Enable EAN-8 Supplement 1 0=No 1 = 2 Char 2=5 Char 3 =2or5 Char 4 = Auto

Publication 2755-833

Page 295 read from a scan by OCR; it may hold reading errors

Decoder Configuration Addresses

. . Number of Acceptable Values PCCC Address Configuration Parameter Bytes (Default in bold) 3EE Enable EAN-13 Supplement 1 0=No 1 =2 Char 2 =5 Char 3 =2 or 5 Char 4 = Auto 3EF Display Formatted Data 1 0 = None 1 = AUX/LCD 2 = AUX Only 3 =LCD Only 3F0 AUX Terminal/LCD message display format 1 0 = Unformatted 1 = Host Format 3F1 Starting Position 1 00 - 80 bar_code_strings 00 = Disable 3F2 Starting Position 1 00 - 80 decoder performance 00 = Disable 3F3 Starting Position 1 00 - 80 package counter 00 = Disable 3F4 Starting Position 1 00 - 80 symbols not read counter 00 = Disable 3F5 Starting Position 1 00 - 80 primary counter 1 00 = Disable 3F6 Starting Position 1 00 - 80 primary counter 2 00 = Disable 3F7 Starting Position 1 00 - 80 primary counter 3 00 = Disable 3F8 Starting Position 1 00 - 80 primary counter 4 00 = Disable 3F9 Starting Position 1 00 - 80 primary counter 5 00 = Disable 3FA Starting Position 1 00 - 80 primary counter 6 00 = Disable 3FB Starting Position 1 00 - 80 primary counter 7 00 = Disable 3FC Starting Position 1 00 - 80 primary counter 8 00 = Disable 3FD Send Performance indicator in host_message 1 0=No 1 = Yes 3FE Enable Filter and Sense of Package_Detect_B 1 0 =No filter, LO=Package Input 1 = Filter (15 ms), LO = Package 2 = No filter, HI = Package 3 = Filter, Hl = Package 3FF Ignored 1 400 Send bar_code_strings in host_message 1 0=No 1= Yes 401 Send package count in host_message 1 0=No 1 = Yes 402 Send bar code symbology in host message 1 0=No 1 = Yes 403 Ignored 1 404 Ignored 1 405 Ignored 1 406 Expand UPC-E 1 0=No 1 = Yes

Publication 2755-833

Page 296 read from a scan by OCR; it may hold reading errors

Decoder Configuration Addresses

PCCC Address

Configuration Parameter

Number of Acceptable Values Bytes (Default in bold)

407

Field delimiter

1 ASCII 1, 255, 255 = None

408

Start Character

1 ASCII 1, 255, 255 = None

409

End Message

1 0 = CrLf 1=Cr 2=Lf

3 = Etx

4 = None

5 = CrEtx 6 = LfEtx

7 = CrLfEtx

40A

Transmission Check

1 0 = None

1=LRC

2 = Checksum-LSB 3 = Checksum-MSB

40B

Code 39 Check Character

1 0=No 1 = Yes

40C

Include Code 39 Check Character

1 0=No 1 = Yes

40D

Interleaved 2-of 5 Check Character

1 0=No 1 = Yes

40E

Include Interleaved 2 - -of 5 Check Character

1 0=No 1 = Yes

40F

Codabar Check Character

1 0=No 1 = Yes

410

Include Codabar Check Character

1 0=No 1 = Yes

411

Host Port - Baud Rates

1 0 = 9600 1 = 4800 2 = 2400 3 = 1200 4 = 300

5 = 38400 6 = 19200

412

Host Port - Bits/Char

1 0 = 8 Data, 1 Stop 1 = 8 Data, 2 Stop 2 =7 Data, 1 Stop 3 =7 Data, 2 Stop

413

Host Port, Parity

1 0 = None 1 = Even 2 = Odd

414

Host Port, - ACK Char

1 ASCII 0, 255, 255 = None

415

Host Port, - NAK Char

1 ASCII 0, 255, 255 = None

416

Scanner A Start Scan Char

1 ASCII 0, 255, 255 = None

417

Scanner A Stop Scan Char

1 ASCII 0, 255, 255 = None

418

Enable Large Buffer

1 0=No 1 = Yes

419

Send Message to Host

1 0 = End of Trigger 1 = After valid_package

Publication 2755-833

Page 297 read from a scan by OCR; it may hold reading errors

Decoder Configuration Addresses

. . Number of Acceptable Values PCCC Address Configuration Parameter Bytes (Default in bold) 41A Host Protocol 1 0 = *RS232 (read-ONLY) 1 = RS232 XON/XOFF 2 = RS232 CTS/RTS - 1 3 = RS232 CTS/RTS - 2 4 = RS422 5 = RS422 XON/XOFF 6 = RS485 PCCC - 1 7 = RS485 PCCC - 2 8 = RS485 ASCII - 1 9 = RS485 ASCII -2 41B Device Address 1 00, 01, ... 31 (read-ONLY) 41C Enable Filter and Sense of Package_Detect_A 1 0 = No Filter, LO={Package Input 1 = Filter (15 msec), LO=Package 2 = No Filter, Hl=Package 3 = Filter (15 msec), Hl=Package 41D Enable Code 39 1 0=No 1 = Yes (No for Pharma-code units) 41E thru 425 =| Code 39 Specific Lengths 8 0...64 426 Enable Interleaved 2-of 5 1 0=No 1=Yes 427 thru 42e Interleaved 2-of 5 Specific Lengths 8 0 ... 64 (Must be even) 42F Enable Code 128 1 0=No 1=Yes 430 thru 437 Code 128 Specific Lengths 8 0 ... 64 438 Enable Codabar 1 0=No 1=Yes 439 thru 440 Codabar Specific Lengths 8 0, 2 ... 64 441 Enable UPC-A 1 0=No 1=Yes 442 Enable UPC-E 1 0=No 1=Yes 443 Enable EAN-8 1 0=No 1=Yes 444 Enable EAN-13 1 0=No 1=Yes 445 LASER Light (A) 1 0=On 1 = Triggered 2 = Off 446 Decode Mode 1 0 = Package Detect 1 =Host 2 = Internal Timer 3 = Continuous 4 = Continuous/Unique 447 Capture Count 1 0, 1, 2, ... 8, 0 = Verify 448 symbols/scan 1 0 = Any 1=1 2=2 3=3 4=4 5=5 6=6 449 symbols/package 1 1 ... 16

Publication 2755-833

Page 298 read from a scan by OCR; it may hold reading errors

Decoder Configuration Addresses A-5

. . Number of Acceptable Values PCCC Address Configuration Parameter Bytes (Default in bold) 44A Match Complete Count 1 1 ... 16 44B Scanner A - Source Identifier String Length 1 0-4, 0 = Empty String 4 4 characters 450 Header string String Length 1 0-32, 0 = Empty String 32 32 characters 471 No-Read String Length 1 0-32, 0 = Empty String 32 32 characters 492 No-Read Timer 2 0, 10 ... 9999 0 = None 494 Inter-Scan Timer 2 0, 10 ... 9999 0 = None 496 symbology in Match Code Table Entry 1 1 0 = Code 39 1 = Interleaved 2 of 5 2 = Codabar 3 = UPC-A 4 =UPC-E 5 =EAN-8 6 = EAN-13 7 = Code 128 8 = Pharma-Code 15 = ANY 497 Enable Match Code Table Entry 1 1 Ignored 498 Match Code 1 String Length 1 0-32, 0 = Empty String 32 32 characters 4B9 Output 1 Event 1 0 = None 1 = Read Package 2 = No-Read Package 3 = Match Complete 4 = Match Entry 5 = Read and no-match 6 = No-Read or no-match 7 = Auto Load 8 = Invalid 9 = Host Buffer Full A = Host Buffer Overflow B = Open C = Closed 4BA Output 1 Duration 2 0, 10... 9999 0 = None 4BC symbology in Match Code Table Entry 2 1 0 = Code 39 1 = Interleaved 2 of 5 2 = Codabar 3 = UPC-A 4 =UPC-E 5 =EAN-8 6 = EAN-13 7 = Code 128 8 = Pharma-Code 15 = Any 4BD Enable Match Code Table Entry 2 1 Ignored 4BE Match Code 2 String Length 1 0-32, 0 = Empty String 32 32 characters

Publication 2755-833

Page 299 read from a scan by OCR; it may hold reading errors

Decoder Configuration Addresses

PCCC Address

Configuration Parameter

Number of Bytes

Acceptable Values (Default in bold)

4DF

Output 2 Event

1

0 = None

1 = Read Package

2 = No-Read Package

3 = Match Complete

4 = Match Entry

5 = Read and no-match 6 = No-Read or no-match 7 = Auto Load

8 = Invalid

9 = Host Buffer Full

A= Host Buffer Overflow B = Open

C = Closed

4E0

Output 2 Duration

0, 10 ... 9999 0 = None

4E2 symbology in Match Code Table Entry 3

0 = Code 39

1 = Interleaved 2 of 5 2 = Codabar

3 = UPC-A

4 = UPC-E

5 = EAN-8

6 = EAN-13

7 = Code 128

8 = Pharma-Code

15 = Any

4E3

Enable Match Code Table Entry 3

Ignored

4E4

Match Code 3 String Length String

32

0-32, 0 = Empty 32 characters

505

Output 3 Event

0 = None

1 = Read Package

2 = No-Read Package

3 = Match Complete

4 = Match Entry

5 = Read and no-match 6 = No-Read or no-match 7 = Auto Load

8 = Invalid

9 = Host Buffer Full

A= Host Buffer Overflow B = Open

C = Closed

506

Output 3 Duration

0, 10 ... 9999 0 = None

508 symbology in Match Code Table Entry 4

0 = Code 39

1 = Interleaved 2 of 5 2 = Codabar

3 = UPC-A

4 = UPC-E

5 = EAN-8

6 = EAN-13

7 = Code 128

8 = Pharma-Code

15 = Any

509

Enable Match Code Table Entry 4

Ignored

50A

Match Code 4 String Length String

32

0-32, 0 = Empty 32 characters

Publication 2755-833

Page 300 read from a scan by OCR; it may hold reading errors

Decoder Configuration Addresses A-7

PCCC Address

Configuration Parameter

Number of Bytes

Acceptable Values (Default in bold)

52B

Output 4 Event

1

0 = None

1 = Read Package

2 = No-Read Package

3 = Match Complete

4 = Match Entry

5 = Read and no-match 6 = No-Read or no-match 7 = Auto Load

8 = Invalid

9 = Host Buffer Full

A= Host Buffer Overflow B = Open

C = Closed

52C

Output 4 Duration

0, 10 ... 9999 0 = None

52E symbology in Match Code Table Entry 5

0 = Code 39

1 = Interleaved 2 of 5 2 = Codabar

3 = UPC-A

4 = UPC-E

5 = EAN-8

6 = EAN-13

7 = Code 128

8 = Pharma-Code

15 = Any

52F

Enable Match Code Table Entry 5

Ignored

530

Match Code 5 String Length String

0-32, 0 = Empty 32 characters

551

Output 5 Event

0 = None

1 = Read Package

2 = No-Read Package

3 = Match Complete

4 = Match Entry

5 = Read and no-match 6 = No-Read or no-match 7 = Auto Load

8 = Invalid

9 = Host Buffer Full

A= Host Buffer Overflow B = Open

C = Closed

552

Output 5 Duration

0, 10 ... 9999 0 = None

554 symbology in Match Code Table Entry 6

0 = Code 39

1 = Interleaved 2 of 5 2 = Codabar

3 = UPC-A

4 = UPC-E

5 = EAN-8

6 = EAN-13

7 = Code 128

8 = Pharma-Code

15 = Any

555

Enable Match Code Table Entry 6

Ignored

556

Match Code 6 String Length String

0-32, 0 = Empty 32 characters

Publication 2755-833

Page 301 read from a scan by OCR; it may hold reading errors

Decoder Configuration Addresses

PCCC Address

Configuration Parameter

Number of Bytes

Acceptable Values (Default in bold)

577

Output 6 Event

1

0 = None

1 = Read Package

2 = No-Read Package

3 = Match Complete

4 = Match Entry

5 = Read and no-match 6 = No-Read or no-match 7 = Auto Load

8 = Invalid

9 = Host Buffer Full

A= Host Buffer Overflow B = Open

C = Closed

578

Output 6 Duration

0, 10 ... 9999 0 = None

57A symbology in Match Code Table Entry 7

0 = Code 39

1 = Interleaved 2 of 5 2 = Codabar

3 = UPC-A

4 = UPC-E

5 = EAN-8

6 = EAN-13

7 = Code 128

8 = Pharma-Code

15 = Any

57B

Enable Match Code Table Entry 7

Ignored

57C

Match Code 7 String Length String

32

0-32, 0 = Empty 32 characters

59D

Output 7 Event

0 = None

1 = Read Package

2 = No-Read Package

3 = Match Complete

4 = Match Entry

5 = Read and no-match 6 = No-Read or no-match 7 = Auto Load

8 = Invalid

9 = Host Buffer Full

A= Host Buffer Overflow B = Open

C = Closed

59E

Output 7 Duration

0, 10 ... 9999 0 = None

5A0 symbology in Match Code Table Entry 8

0 = Code 39

1 = Interleaved 2 of 5 2 = Codabar

3 = UPC-A

4 = UPC-E

5 = EAN-8

6 = EAN-13

7 = Code 128

8 = Pharma-Code

15 = Any

5A1

Enable Match Code Table Entry 8

Ignored

5A2

Match Code 8 String Length String

32

0-32, 0 = Empty 32 characters

Publication 2755-833

Page 302 read from a scan by OCR; it may hold reading errors

Decoder Configuration Addresses

PCCC Address

Configuration Parameter

Number of Bytes

Acceptable Values (Default in bold)

5C3

Output 8 Event

1

0 = None

1 = Read Package

2 = No-Read Package 3 = Match Complete

4 = Match Entry

5 = Read and no-match 6 = No-Read or no-match 7 = Auto Load

8 = Auto Load Input

9 = Host Buffer Full

A= Host Buffer Overflow B = Open

C = Closed

5C4

Output 8 Duration

0, 10 ... 9999 0 = None

5C6

Ignored

382

5E6

Output 1 Normally Open or Closed

0 = Normally Open 1 = Normally Closed

5E7

Output 2 Normally Open or Closed

0 = Normally Open 1 = Normally Closed

5E8

Output 3 Normally Open or Closed

0 = Normally Open 1 = Normally Closed

5E9

Output 4 Normally Open or Closed

0 = Normally Open 1 = Normally Closed

5EA

Output 5 Normally Open or Closed

0 = Normally Open 1 = Normally Closed

5EB

Output 6 Normally Open or Closed

0 = Normally Open 1 = Normally Closed

5EC

Output 7 Normally Open or Closed

0 = Normally Open 1 = Normally Closed

5ED

Output 8 Normally Open or Closed

0 = Normally Open 1 = Normally Closed

Publication 2755-833

Page 303 read from a scan by OCR; it may hold reading errors

A-10 Decoder Configuration Addresses

Decoder Function or Command Addresses

Refer to Chapter 16 for additional information on the use of these commands and functions.

Address Command 0600H Clear package counts 0604H Clear primary count 1 0608H Clear primary count 2 060CH Clear primary count 3 0610H Clear primary count 4 0614H Clear primary count 5 0618H Clear primary count 6 061CH Clear primary count 7 0620H Clear primary count 8 0624H Clear symbols not read count 0630H Clear all primary counts 0631H Clear all primary counts and symbols not read count 0632H Save configuration to Storage Memory and restart 0633H Set configuration to default values 0634H Start scan A 0635H Stop scan A 0636H Flush current packet from host buffer 0637H Restart decoder 0640H Send repeat read 0641H Cancel repeat read 0642H Clear all Extended counts 0643H Auto-Load Start 0644H Auto-load End 0650H Hold output 1 open 0651H Hold output 2 open 0652H, _| Hold output 3 open 0653H Hold output 4 open 0654H Hold output 5 open 0655H Hold output 6 open 0656H Hold output 7 open 0657H Hold output 8 open” 0660H Hold output 1 closed” 0661H Hold output 2 closed” qaqa qgqgagqa

® The AUX port supports a terminal for either configuring the decoder or for man entry. For information on use of the AUX port for manual data entry, consult Chi

Publication 2755-833

Page 304 read from a scan by OCR; it may hold reading errors

Decoder Configuration Addresses A-11

Address Command 0662H Hold output 3 closed 0663H Hold output 4 closed? 0664H Hold output 5 closed? 0665H Hold output 6 closed 0666H Hold output 7 closed?

0667H Hold output 8 closed? 0668H Start Scanner B Trigger 0669H Stop Scanner B Trigger

Pharma - Code Configuration 0700H-0725H

The decoder shall use the existing ’set match table symbology type’ command with a value of 9 to set the match table symbology type to PHARMA.

The table below shows the mapping between the PCCC Host Commands and the parameters described in the PHARMA-CODE CONFIGURATION PARAMETERS Section.

. . Number of Acceptable Values PCCC Address Configuration Parameter Bytes (Default in bold) 700H enable Pharma - Code 1 0=No 1= Yes 701H decode direction 1 0 = Forward 1 = Reverse 2 = Forward A Reverse B 3 = Reverse A Forward B 702H quiet zone ratio 1 4-10, 5 = Default, 0 = Use Default 703H space tolerance 1 0 = Ignore 5 to 40, 15 704H bar tolerance 1 0 = Ignore 5 to 40, 15 705H minimum number of bars 1 3to 12,5 706H wide to narrow bar ratio 1 0 = Midrange 2to4 707H code verification list entry 1 2 0 = none 7 to 8190 709H to 725H, _| code verification list entry 2 through 16 2 bytes per | 0=none entry 7 to 8190

@® The AUX port supports a terminal for either configuring the decoder or for man entry. For information on use of the AUX port for manual data entry, consult Chi

Publication 2755-833

Page 305 read from a scan by OCR; it may hold reading errors

A-12

Decoder Configuration Addresses

Publication 2755-833

Series B Configuration Parameters 0900H-0901H

PCCC Address

Configuration Parameter

Number of Bytes

Acceptable Values (Default in bold)

900H write text message to AUX/LCD string length string

1 128

0 - 128, 0 = Empty 128 characters

901H write text message to AUX/LCD and enable keyboard entry string length string

128

0 - 128, 0 = Empty 128 characters

Series B Configuration Parameters OEQOH-OEFFH

PCCC Address

Configuration Parameter

Number of Bytes

Acceptable Values (Default in bold)

E10

Verify Interleaved 2 of 5 guard bars

1

0=No 1 = Yes

E11

Scanner source of event 1

1 = Scanner A 2 = Scanner B 3=A\B 5=AB

E12

Scanner source of event 2

1 = Scanner A 2 = Scanner B 3=A\B 5=AB

E13

Scanner source of event 3

1 = Scanner A 2 = Scanner B 3=A\B 5=AB

E14

Scanner source of event 4

1 = Scanner A 2 = Scanner B 3=A\B 5=AB

E15

Scanner source of event 5

1 = Scanner A 2 = Scanner B 3=A\B 5=AB

E16

Scanner source of event 6

1 = Scanner A 2 = Scanner B 3=A\B 5=AB

E17

Scanner source of event 7

1 = Scanner A 2 = Scanner B 3=A\B 5=AB

E18

Scanner source of event 8

1 = Scanner A 2 = Scanner B 3=A\B 5=AB

E19

Laser B On mode

0 = Continuous 1 = Triggered 2=Off

E1A

Set number of Fields in host_message

0-16,0= ALL

E1B

FNC1 Character

00-FFh, 00 = Ignore

E1C

Quiet Zone Ratio

4-10, 5 = Default, 0 = Use Default

Page 306 read from a scan by OCR; it may hold reading errors

Decoder Configuration Addresses

A-13

. . Number of Acceptable Values PCCC Address Configuration Parameter Bytes (Default in bold) E1D Scanner B Start Scan Character 1 ASCII 0 - 255, 255 = None E1E Scanner B Stop Scan Character 1 ASCII 0 - 255, 255 = None E1F Extended Match Set 1 (1 - 16) 1 0 = Disabled 1 = Enabled E20 Extended Match Set 2 (17 - 32) 1 0 = Disabled 1 = Enabled E21 Extended Match Set 3 (33 - 48) 1 0 = Disabled 1 = Enabled E22 Extended Match Set 4 (49 - 64) 1 0 = Disabled 1 = Enabled E23 Extended Match Set 5 (65, 80) 1 0 = Disabled 1 = Enabled E24 Extended Match Set 6 (81 - 96) 1 0 = Disabled 1 = Enabled E25 Extended Match Set 7 (97 - 112) 1 0 = Disabled 1 = Enabled E26 Extended Match Set 8 (113 - 128) 1 0 = Disabled 1 = Enabled Host Message Replacement Rules 1000H-143FH . . Number of Acceptable Values PCCC Address Configuration Parameter Bytes (Default in bold) 1000H+i*40H host_message Field 1 Oto 16, O= ALL 1001H+i*40H Source 1 1 = Scanner A 2 = Scanner B 3=A\B 4= AUX 1002H+i*40H symbology 1 0 = Code 39 1 = Interleaved 2-of-5 2 = Codabar 3 = UPC-A 4=UPC-E 5 = EAN-8 6 = EAN-13 7 =Code 128 8 = Pharma- - Code Ofh = ANY 1003H+i*40H symbol_number 1 Oto 16, O=ALL 1004H+i*40H Minimum Field Length 1 0 to 64 1005H+i*40H Alignment 1 0 = Right 1 =Left 1006H+i*40H Fill Character 1 0 to 255, 0 = None 1007H+i*40H Reserved 1 1 1008H+i*40H Search Pattern Length 1 0-24, 0 = Empty Search Pattern 24 up to 24 characters 1021H+i*40H Reserved 3 1 1024H+i*40H Replace Pattern Length 1 0-24, 0 = Empty Replace Pattern 24 up to 24 characters 103DH+i*40H Reserved 38 1

Publication 2755-833

Page 307 read from a scan by OCR; it may hold reading errors

A-14

Decoder Configuration Addresses

Publication 2755-833

Where i ranges from 1 to 16. The decoder shall return status 10H for references to 1|OOOH - 103FH.

Host Message No Read Replacement Strings 2000H-21B9H

. . Number of Acceptable Values PCCC Address Configuration Parameter Bytes (Default in bold) 2000H+i*1AH Search Fail String Length 1 0-24 0 = Empty Search Fail String 24 up to 24 characters 2019H+i*1AH Reserved 1 1 Where i ranges from 1 to 16. The decoder shall return status 10H for references to 2000H - 2019H. Extended Count Values D800H-DA03H . . Acceptable Values PCCC Address Configuration Parameter Number of Bytes (Default in bold) D800H+i*4 Extended Count Value n 4 0 to 999999 Where i ranges from 1 to 128. The decoder shall return status code 10H for references to addresses D8O0OH-D803H. Extended Match Data 8000H-A03FH Writes to address 8000 will be interpreted as Autoload. The data attached to the write must follow the byte order listed in the following table. The data will be inserted in the next available autoload position, searching first the primary and then the extended data table. That entry will be marked as “Match Entry”. If no entries are available in either table, a code 02 (memory not available) will be returned. Writes to any location other than 8000 will return of code 10, and the write request will be ignored. . . Number of Acceptable Values PCCC Address Configuration Parameter Bytes (Default in bold) 8000H Source 1 1 = Scanner A 2 = Scanner B symbology 1 0 = Code 39 1 = Interleaved 2-of-5 2 = Codabar 3 = UPC-A 4=UPC-E 5 = EAN-8 6 = EAN-13 7 = Code 128 8 = Pharma-Code Match pattern, Length 1 0-32, 0 = Empty Match pattern - String 32 up to 32 characters

Page 308 read from a scan by OCR; it may hold reading errors

Decoder Configuration Addresses A-15

Extended Match Data 8000H-A03FH

The following table lists the configuration parameters for the Extended Match Data Table. Address the counters by adding the offset i * 40 H to the base address 8000, where i represents the counter number, | to 128.

. . Number of Acceptable Values PCCC Address Configuration Parameter Bytes (Default in bold)

8000H+i*40H Mode 1 0 = Disabled

1 = Match_entry

2 = Auto-Load

3=Lot 8001H+i*40H Source 1 1 = Scanner A

2 = Scanner B

3=A\B

5=A-B 8002H+i*40H symbology 1 0 = Code 39

1 = Interleaved 2-of-5

2 = Codabar

3 = UPC-A

4=UPC-E

5 =EAN-8

6 = EAN-13

7 = Code 128

8 = Pharma - Code

F = ANY 8003H+i*40H Reserved 1 1 8004H+i*40H Count 4 0 to 999999 8008H+i*40H Loading: Discrete 1 0 = no discrete

1 to 9, or aH = always 8009H+i*40H Loading: Discrete 2 8 0 = no discrete

1 to 9, or aH = always 800AH+i*40H Loading: Discrete 3 8 0 = no discrete

1 to 9, or aH = always 800BH+i*40H Loading: Discrete 4 8 0 = no discrete

1 to 9, or aH = always 800CH+i*40H Loading: Discrete 5 8 0 = no discrete

1 to 9, or aH = always 800DH+i*40H Loading: Discrete 6 8 0 = no discrete

1 to 9, or aH = always 800EH+i*40H Loading: Discrete 7 8 0 = no discrete

1 to 9, or aH = always 8008F+i*40H Loading: Discrete 8 8 0 = no discrete

1 to 9, or aH = always 8010H+i*40H Reserved 14 1 801EH+i*40H Match pattern, Length 1 0-32, 0 = Empty

Match pattern, String 32 up to 32 characters

803FH+i*40H Reserved 1 1

Publication 2755-833