Page 74

Configuration: Symbology Configure Symbology

Option 1 on the Select Operation menu accesses the Symbology configuration screen. Use this function to select symbologies for decoding and to define the operating parameters to use during decoding. The screen is displayed with the first field highlighted.

The default settings are displayed the first time you access this screen. Make changes appropriate for your application. If the factory defaults are satisfactory, you can return to the Select Operation menu by pressing [Esc] twice. The parameters on this screen:

• Enable symbologies for decoding • Enable specific length checking, which serves two purposes: – provides data integrity for variable length symbologies by protecting against short reads. The decoder will only decode bar code symbols that contain the exact number of characters specified in the length fields. Especially useful for Interleaved 2 of 5 when check characters are not being used. – optimizes operations by allowing the decoder to select scans for decoding from several labels with different lengths. For example, the decoder can select the 6 character code from a carton that has 14, 6, and 4 character codes

• • • •

Enable supplements for UPC/EAN symbologies Enable verification of guard bars with Interleaved 2-of-5 symbols Adjust and set the quiet zone ratio (if necessary) Configure parameters for Pharma–Code labels.

Publication 2755-833

Page 75

6–2

Configuration: Symbology

The decoder will auto discriminate between multiple symbologies. For optimum performance, enable only those symbologies and code lengths you intend to use. The following pages define each symbology parameter along with the field type and possible values. The default value is shown in bold letters.

Code 39 Field Type Options Select

No Yes

Enables/disables decoding of Code 39 bar code labels. The default of Yes (except on Pharma-Code decoders) enables decoding of this symbology. Select No to disable decoding.

Code 39 Specific Lengths Field Type Options Edit Numeric 0 through 64 (0)

Sets length checking for Code 39 bar code labels. The default is 0, which means the decoder does not check lengths. You can specify up to 8 code lengths (maximum of 64 characters). The code length includes the check character, but not the start and stop characters. If you specify a code length other than 0, the decoder will only decode labels with the number of characters specified. Important: Enter specific lengths starting with the leftmost blank field. Specific lengths entered to the right of a blank field are ignored. Correct

Incorrect

15 is to the right of a blank field and will be ignored.

Publication 2755-833

Page 76

Configuration: Symbology

6–3

Code 39 Check Character Field Type Options Select

No Yes

Controls whether the decoder is required to compute and verify a code check character for Code 39 bar codes. The code check character ensures that the data is read correctly. The default is No, which means the decoder treats all decoded characters as data. The Code 39 check character is computed as a Modulus 43 sum of all characters value as specified in the AIM specification USS-39.

Include Code 39 Check Character Field Type Options Select

No Yes

Controls whether the code 39 check character computed by the decoder is included in the message sent to the host. The default is No, which means the Code 39 check character is not sent to the host.

Interleaved 2-of-5 Field Type Options Select

No Yes

Enables/disables decoding of Interleaved 2-of-5 bar code labels. The default of No disables decoding of this symbology. Select Yes to enable decoding.

Interleaved 2-of-5 Specific Lengths Field Type Options Edit Numeric

Even numbers 2 through 64 (0)

Sets length checking for Interleaved 2-of-5 bar code labels. The default is 0, which means the decoder does not check lengths. You can specify up to 8 code lengths (maximum of 64 characters). Only even numbers (2-64) are allowed. The code length includes the check character, but not the start and stop characters. If you specify a code length other than 0, the decoder will only decode labels with the number of characters specified.

Publication 2755-833

Page 77

6–4

Configuration: Symbology

We recommend that you enter specific lengths for Interleaved 2-of-5 labels. Otherwise, a partial scan of symbols could result in a valid shorter read. The decoder will ignore 2 character Interleaved 2-of-5 labels unless you enter a specific length of 2.

Interleaved 2-of-5 Check Character Field Type Options Select

No Yes

Controls whether the decoder is required to compute and verify a code check character for Interleaved 2 of 5 bar codes. The code check character ensures that the data is read correctly. The default is No, which means the decoder treats all decoded characters as data. The Interleaved 2 of 5 character is computed as a Modulus 10 sum of all characters value as specified in the AIM specification USS-I 2/5.

Include Interleaved 2-of-5 Check Character Field Type Options Select

No Yes

Controls whether the Interleaved 2 of 5 check character computed by the decoder is included in the message sent to the host. The default is No, which means the Interleaved 2 of 5 check character is not sent.

Interleaved 2-of-5 Guard Bars Field Type Options Select

No Yes

Controls verification of the presence of guard bars on Interleaved 2-of-5 symbols. The default of No results in no verification. Select Yes to activate guard bar verification.

Publication 2755-833

Page 78

Configuration: Symbology

6–5

Codabar Field Type Options Select

No Yes

Enables/disables decoding of Codabar labels. The default of No disables decoding of this symbology. Select Yes to enable decoding.

Codabar Specific Lengths Field Type Options Edit Numeric 0 through 64 (0)

Sets length checking for Codabar labels. The default is 0, which means the decoder does not check lengths. You can specify up to 8 code lengths (maximum of 64 characters). The code length includes the check character and the start and stop characters. If you specify a code length other than 0, the decoder will only decode labels with the number of characters specified.

Codabar Check Character Field Type Options Select

No Yes

Controls whether the decoder is required to compute and verify a code check character for Codabar bar codes. The code check character ensures that the data is read correctly. The default is No, which means the decoder treats all decoded characters as data. The Codabar character is computed as a Modulus 16 sum of all characters value as specified in the AIM specification USS-Codabar.

Include Codabar Check Character Field Type Options Select

No Yes

Controls whether the Codabar check character computed by the decoder is included in the message sent to the host. The default is No, which means the Codabar check character is not sent.

Publication 2755-833

Page 79

6–6

Configuration: Symbology

Code 128 Field Type Options Select

No Yes

Enables/disables decoding of Code 128 labels. The default of No disables decoding of this symbology. Select Yes to enable decoding.

Code 128 Specific Lengths Field Type Options Edit Numeric 0 through 64 (0)

Sets length checking for Code 128 labels. The default is 0, which means the decoder does not check lengths. You can specify up to 8 code lengths (maximum of 64 characters). The code length does not include the check character or the start and stop characters.① If you specify a code length other than 0, the decoder will only decode labels with the number of characters specified. The decoder uses the specific length parameter in three ways:

• The decoder discards decoded symbols with lengths that do not match the specific length parameter This allows you to filter out all decoded symbols except those that have a specific length that appears in the specific length table. • The decoder uses it to determine if the number of bar to space transitions that occur during a scan is appropriate for the symbologies and specific length values Scans that occur in the absence of a symbol or part of a symbol are not valid, and therefore result in extra processing overhead for the decoder. The decoder discards these scans before the microprocessor sees them. • Once the microprocessor sees a scan, it uses the specific length parameter to search within the symbol for a valid number of bar to space transitions

①

Publication 2755-833

The decoder will ignore Code 128 FNC2, FNC3, and FNC4 characters regardless of the Code 128 FN Character setting. FNC2, FNC3, and FNC4 are also ignored by the specific length parameter.

Page 80

Configuration: Symbology

6–7

This check differs from the one above, because instead of looking at the number of transitions in the entire scan, this search only considers the number of transitions contained within the symbol. The decoder rejects the scan if the number of transitions does not correspond to a selected specific length. It attempts to decode all scans if no specific length is specified.

Code 128 FNC1 Character Field Type Options Edit

Valid ASCII 0 = None

Instructs the decoder to substitute any valid ASCII character for the Code 128 FNC1 (Function 1) character. The default is 0 (None), which means no substitution will take place. The substitution will take place at the time of decoding, and before any rules or match operations are applied. Users frequently substitute the ASCII 29 character (CTRL ]) for the FNC1 character.

UPC-A Field Type Options Select

No Yes

Enables/disables decoding of UPC-A labels. The default of No disables decoding of this symbology. Select Yes to enable decoding.

UPC-A Supplements Field Type Options None 2 Select 5 2 or 5 Auto

Enables/disables decoding of UPC-A supplementary codes. The default of None disables decoding of supplements for this symbology. Options are:

Publication 2755-833

Page 81

6–8

Configuration: Symbology

None 2 5 2 or 5 Auto

Disables decoding of supplementary codes. Enables decoding of 2 character supplementary codes. Enables decoding of 5 character supplementary codes. Enables decoding of 2 or 5 character supplementary codes. Enables decoder to auto discriminate supplementary codes (None, 2 or 5) on label①

① The Auto Selection allows you to mix labels without supplements with labels containing 2 or 5 digit supplements. The supplements are often a different size than the primary symbol. Therefore, it is critical that both the primary symbol and the supplement be present when the decoder is triggered. If the decoder does not detect the supplement, the primary symbol is sufficient to produce a valid scan. The Auto selection is not recommended when the Decode Mode is set to Continuous.

If you select 2, 5, or 2 or 5, the decoder must decode both the primary label and the supplement to produce a valid scan.

UPC-E Field Type Options Select

No Yes

Enables/disables decoding of UPC-E labels. The default of No disables decoding of this symbology. Select Yes to enable decoding.

UPC-E Supplements Field Type Options None 2 Select 5 2 or 5 Auto

Enables/disables decoding of UPC-E supplementary codes. The default of None disables decoding of supplements for this symbology. Options are: None 2 5 2 or 5 Auto

Disables decoding of supplementary codes. Enables decoding of 2 character supplementary codes. Enables decoding of 5 character supplementary codes. Enables decoding of 2 or 5 character supplementary codes. Enables decoder to auto discriminate supplementary codes (None, 2 or 5) on label①

① The Auto Selection allows you to mix labels without supplements with labels containing 2 or 5 digit supplements. The supplements are often a different size than the primary symbol. Therefore, it is critical that both the primary symbol and the supplement be present when the decoder is triggered. If the decoder does not detect the supplement, the primary symbol is sufficient to produce a valid scan. The Auto selection is not recommended when the Decode Mode is set to Continuous.

If you select 2, 5, or 2 or 5, the decoder must decode both the primary label and the supplement to produce a valid scan.

Publication 2755-833

Page 82

Configuration: Symbology

6–9

Expand UPC-E Field Type Options Select

No Yes

Controls whether the UPC-E bar code is transmitted in a 12 digit (expanded) format. The default is No, which means do not send the expanded form but the 6 digit (compressed) form.

EAN-8 Field Type Options Select

No Yes

Enables/disables decoding of EAN-8 labels. The default of No disables decoding of this symbology. Select Yes to enable decoding.

EAN-8 Supplements Field Type Options None 2 Select 5 2 or 5 Auto

Enables/disables decoding of EAN-8 supplementary codes. The default of None disables decoding of supplements for this symbology. Options are: None 2 5 2 or 5 Auto

Disables decoding of supplementary codes. Enables decoding of 2 character supplementary codes. Enables decoding of 5 character supplementary codes. Enables decoding of 2 or 5 character supplementary codes. Enables decoder to auto discriminate supplementary codes (None, 2 or 5) on label①

① The Auto Selection allows you to mix labels without supplements with labels containing 2 or 5 digit supplements. The supplements are often a different size than the primary symbol. Therefore, it is critical that both the primary symbol and the supplement be present when the decoder is triggered. If the decoder does not detect the supplement, the primary symbol is sufficient to produce a valid scan. The Auto selection is not recommended when the Decode Mode is set to Continuous.

If you select 2, 5, or 2 or 5, the decoder must decode both the primary label and the supplement to produce a valid scan.

Publication 2755-833

Page 83

6–10

Configuration: Symbology

EAN-13 Field Type Options Select

No Yes

Enables/disables decoding of EAN-8 labels. The default of No disables decoding of this symbology. Select Yes to enable decoding.

EAN-13 Supplements Field Type Options None 2 Select 5 2 or 5 Auto

Enables/disables decoding of EAN-13 supplementary codes. The default of None disables decoding of supplements for this symbology. Options are: None 2 5 2 or 5 Auto

Disables decoding of supplementary codes. Enables decoding of 2 character supplementary codes. Enables decoding of 5 character supplementary codes. Enables decoding of 2 or 5 character supplementary codes. Enables decoder to auto discriminate supplementary codes (None, 2 or 5) on label①

① The Auto Selection allows you to mix labels without supplements with labels containing 2 or 5 digit supplements. The supplements are often a different size than the primary symbol. Therefore, it is critical that both the primary symbol and the supplement be present when the decoder is triggered. If the decoder does not detect the supplement, the primary symbol is sufficient to produce a valid scan. The Auto selection is not recommended when the Decode Mode is set to Continuous.

If you select 2, 5, or 2 or 5, the decoder must decode both the primary label and the supplement to produce a valid scan.

Enable Pharma-Code Symbology (Pharma-Code Decoders Only) Field Type Options Select

No Yes

Enables decoding of Pharma-Code symbols. The default of Yes enables decoding for this symbology. Select No to disable decoding

Publication 2755-833

Page 84

Configuration: Symbology

6–11

Note: We recommend starting with the default settings for all Pharma-Code parameters except Minimum Number of Bars and Decode Direction, which must be determined by your application. The complex interrelationships among other Pharma-Code options make them best suited for use only by experienced Pharma-Code users in unusual instances when the default values do not provide acceptable results.

Quiet Zone Ratio (All Decoders) Field Type Options Edit Numeric 4 through 10 (5)

Specifies the ratio of the width of the clear space before the first bar to the width of the first bar, or the width of the clear space after the last bar to the width of the last bar; whichever is smaller. Valid quiet zone ratio values are 4 to 10. The default is 5. The default value for this parameter has been optimized for most applications, and it is unlikely you will ever have a reason to change it.

Quiet Zone

Quiet Zone

Narrow Bar

Wide Bar Space

A B

For this example:

If scan direction is A

If scan direction is B

Clear Space Width 1st Bar Width (Wide Bar) Clear Space Width 1st Bar Width (Narrow Bar)

=

5

=

10

The decoder uses the quiet zone to determine the necessary clear space on both sides of the symbol. A symbol not preceded by an adequate quiet zone is ignored.➀ The quiet zone after the bars and spaces of a symbol indicates the end of data. If you specify a quiet zone ratio that is too small, the decoder may interpret a space within the symbol as the end of the symbol, resulting in no-reads or misreads. A general rule to use is: Maximum Space Width in Symbol Minimum Narrow Bar Width ①

Width of the Smallest Quiet Zone Quiet Zone Ratio

Maximum Wide Bar Width

If the Quiet Zone is found to be inadequate, the decoder will examine the symbol further to attempt a d We recommend, however, that all labels be printed within specified limits.

Publication 2755-833

Page 85

6–12

Configuration: Symbology

A typical quiet zone value for the Pharma-Code symbology is 5.

Space Tolerance (Pharma-Code Decoders Only) Field Type Options Edit

5 through 40 (15) Ignore

Defines the percent difference (in width) between the narrowest and widest space elements of the Pharma-Code symbol. Space tolerance is expressed mathematically as: (Widest Space – Narrowest Space) (Widest Space + Narrowest Space)

x 100% = % Space Tolerance

2

Select a value that is greater than the worst case tolerance to prevent no-reads. Valid percent values are 5 to 40, or Ignore. If set to Ignore any amount of space tolerance is allowed within the symbol. The default value is 15 (15%). The default value for this parameter has been optimized for most applications, and it is unlikely you will ever have a reason to change it. The decoder will reject a symbol if two spaces within the symbol differ in width by more than the space tolerance value. Select Ignore to prevent the decoder from rejecting a symbol based on width differences between spaces.

Bar Tolerance (Pharma-Code Decoders Only) Field Type Options Edit

5 through 40 (15) Ignore

Defines the percent difference (in width) between two bars of a symbol that have the same nominal width but the largest width difference. There are two bar tolerances since Pharma-Code symbols have wide and narrow bars. Bar tolerance is expressed mathematically as:

Publication 2755-833

Page 86

Configuration: Symbology

6–13

(Widest Wide Bar – Narrowest Wide Bar ) (Widest Wide Bar + Narrowest Wide Bar )

x 100% = % Bar Tolerance

2 OR (Widest Narrow Bar – Narrowest Narrow Bar) (Widest Narrow Bar + Narrowest Narrow Bar) 2 x 100% = % Bar Tolerance

Select a value that is greater than the worst case tolerance to prevent no-reads. Valid bar tolerance values are 5 to 40, or Ignore. The Ignore value allows any amount of tolerance between bars of the same nominal width. The default value is 15 (15%). The default value for this parameter has been optimized for most applications, and it is unlikely you will ever have a reason to change it. The decoder will reject a symbol if the width of two bars of the same nominal width differs by more than the bar tolerance value. Select Ignore to prevent the decoder from rejecting a symbol based on width differences between bars of the same nominal width.

Minimum Number of Bars (Pharma-Code Decoders Only) Field Type Options Edit 3 through 12 (5)

Specifies the least number of bars that must be present within a Pharma-Code symbol for the decoder to perform a decode. Possible values are 3 to 12. The default is 5. If the Code Verification List contains values, the decoder will ignore the minimum bar setting and decode only those symbols that have values in the list. If the Code Verification List has no values, the decoder will reject all symbols that contain fewer bars than the minimum bar setting.

Publication 2755-833

Page 87

6–14

Configuration: Symbology

Decode Direction (Scanner A or B) (Pharma-Code Decoders Only) Field Type Options Select

Forward Reverse

Sets the direction the decoder uses to decode a scanned label. Direction values are either Forward or Reverse. The default is Forward. The decoder uses the decode direction to determine the least significant bar of a symbol. The examples below show how a Pharma-Code label is decoded depending on the direction. Example 1: The decode direction is set to forward. The decode direction fixes the position of the least significant bar (regardless of scan direction). The decoded value is 94. Most Significant Bar

Least Significant Bar

Scan Direction Decode Direction

94

Decode Direction = Forward Decoded Value = 94

Example 2: The decode direction is set to reverse. The decode direction fixes the position of the least significant bar. The decoded value is 125. Least Significant Bar

Most Significant Bar

Scan Direction Decode Direction

125

Decode Direction = Reverse Decoded Value = 125

Wide to Narrow Bar Ratio (Pharma-Code Decoders Only) Field Type Options Edit

2 through 4 (2) Midrange

Specifies the minimum ratio of the widest bar to the narrowest bar within a symbol. Valid settings are 2 to 4, or midrange. The default is 2. The default value for this parameter has been optimized for most applications, and it is unlikely you will ever have a reason to change it. If the setting is 2 to 4, the decoder will reject symbols whose wide to narrow bar ratio is less than the parameter setting.

Publication 2755-833

Page 88

Configuration: Symbology

6–15

The midrange value is half the sum of the widths of the narrowest and widest bar in the symbol. If the setting is midrange, the decoder will not reject symbols based on the wide to narrow bar ratio setting. Instead, all bars greater than or equal to the midrange are wide bars and all bars less than the midrange are narrow bars. Select midrange to prevent the decoder from rejecting a symbol based on the wide to narrow bar ratio. Note: When set to midrange, the decoder will reject any symbol that contains bars that exactly equal the midrange width.

Code Verification List (Pharma-Code Decoders Only) Field Type Options Edit

7 through 8190 Blank

Defines a list of numeric values the decoder uses to validate decoded Pharma-Code Symbols. Because the orientation of a Pharma-Code label determines its value, you can use the Code Verification List to enhance data security when the value of the symbol is known. The decoder compares the value of the decoded symbol to all entries in the Code Verification List. If the value is in the list, a valid read occurs. If the value is not in the list, the decode is discarded. If all fields are left blank, the list is ignored and the decoder processes reads normally. This prevents inaccurate reads resulting from incorrect label orientation, decode configuration errors, or misreads due to poor label quality. Note: If any value appears in the table, then only symbols that match an entry in the table will match. The Code Verification List holds up to 16 values. Each field is numbered from 1 to 16. You can enter a value from 7 to 8190 in each field or leave the field blank. The default value for each field is blank. Note: The Code Verification List is independent of the Match Code Table (described in the User Manual).

Publication 2755-833