Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 11 of 42

DS/DD Series B Enhanced Bar Code Decoders User Manual (Bulletin 2755): 7 - Configuration: Scanner Control, Primary Match Table, Discrete I/O, pages 89 to 97

Pages 89 to 97 of 361, from DS/DD Series B Enhanced Bar Code Decoders User Manual (Bulletin 2755)

The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Allen-Bradley 2755-DD and Allen-Bradley 2755-DS

Page 89

Configuration: Scanner Control, Primary Match Table, Discrete I/O Scanner Control, Primary Match Code Table, Discrete I/O

Option 2 on the Select Operation configuration screens. Use this function to configure scanner control, match codes, and discrete I/O operations. The screen displays with the first field highlighted.

The factory defaults are displayed the first time you access this screen. Make changes appropriate for your application. If the factory defaults are satisfactory, you can return to the Select Operation menu by pressing [Esc] twice. The parameters are grouped by function on the screen. The following pages describe each group of parameters.

Scanner A Control Parameters These parameters control the operation of Scanner A. Each parameter is defined below. The options for each parameter are summarized in a table, and explained more fully in the text. The default setting for each parameter is displayed in bold letters in the table.

Publication 2755-833

Page 90

7–2

Configuration: Scanner Control, Primary Match Table, Discrete I/O

Laser Light (Scanners A and B) Field Type Options On Select Triggered Off

Determines whether the Scanner A laser is on continuously, turns on and off with the trigger, or is off regardless of the trigger. Use triggered mode with slower package rates to extend the life of your laser. This parameter also affects Scanner B when it is set to operate in coordinated mode with Scanner A. See Scanning Mode under Scanner B Control. On

The scanner scans continuously.

Triggered

The scanner scans only when receiving a trigger from a package detector, host, or internal timer. The scanner continues scanning until an end trigger condition occurs.

Off

Turns the scanner laser off. Use this setting as a safety precaution during decoder maintenance or troubleshooting.

Important: It is important that you understand the following terms before proceeding.

• • • • • valid scan valid symbol valid read valid package no-read

See Glossary for definitions. Decode Mode Field Type Options Continuous Continuous/Unique Select Package Detect Host Internal Timer

Determines how the decoder starts and stops decoding. This parameter affects Scanner A, or Scanner A and B when both are operating in coordinated mode. (See Scanning Mode under Scanner B Control.)

Publication 2755-833

Page 91

Configuration: Scanner Control, Primary Match Table, Discrete I/O

Continuous

7–3

The decoder continuously attempts to decode every scan from the scanner. There is no start and stop control. The continuous mode of operation is useful during initial setup to determine the optimum location of the scanner relative to the bar code labels. (Use a Symbols Per Package value of 1 for setup.) The no-read condition does not exist in this mode.

Continuous/Unique The decoder continuously attempts to decode every scan from the scanner. The decoder discards valid reads that are identical to the previous valid read. The decoder does not process data (send to host or activate appropriate match codes) until a new valid read is decoded. A valid package in continuous/unique mode is a valid read that is different from the previous valid package. The no-read condition does not exist in this mode. Host

A start scan command from a host device triggers the decoder to start decoding. Note: Refer to the section on host communications for additional information on the start and stop scan commands.

Package Detect A package detect signal triggers decoding on and off. The package detect is typically an external presence sensor or the trigger of a hand-held laser scanner. The package detect signals the arrival and departure of a package. Internal Timer This mode uses the No-Read Timer as a trigger source. A set time interval triggers decoding on and off. The No-Read Timer determines the time interval.

Publication 2755-833

Page 92

7–4

Configuration: Scanner Control, Primary Match Table, Discrete I/O

Figure 7.1 Internal timer trigger X

Y

ON

OFF X = Y = No-Read Timer value (in milliseconds) Minimum value = 10 msec Maximum value = 9999 msec➀ Resolution = 5 msec

A no-read occurs if the timer expires before a valid package occurs. The Internal Timer decode mode is useful during initial setup to simulate the package detect signal. Note: When Scanner B is operating independently from Scanner A, its decode mode is always either Package Detect or Host. No-Read Timer Field Type Options Edit 10 through 9999 or 0

Specifies the length of time the decoder will try to decode a label when triggered by a host command or package detector. The timer starts when the decoder is triggered. If a valid package does not occur within the specified time (Symbols/Package setting is not satisfied), a no-read occurs. The default of 0 disables the timer. To set the timer, enter a number between 10 and 9999.➀ Select a value that allows the decoder enough time to read an entire package or a no-read will occur. Note: When the decode mode is set to internal timer, the no-read timer functions as a trigger source. The trigger remains on until the no-read timer expires. See Internal Timer under Decode Mode.

➀ ATTENTION: Set output durations in multiples of 5 milliseconds. Actual output will have a worst-case precision of +0 to –5 milliseconds, varying with the timing of the output. Durations that are not set in multiples of 5 milliseconds will be rounded up to the nearest multiple of 5 and function within the same +0 to –5 millisecond precision. For example, a setting of 25 milliseconds will result in a duration of from 20 to 25 milliseconds. A setting of 23 milliseconds will result in the same duration range.

Publication 2755-833

Page 93

Configuration: Scanner Control, Primary Match Table, Discrete I/O

7–5

Inter-Scan Timer Field Type Options Edit 10 through 9999 or 0

Disables decoding for a set time interval after a valid read. The default is 0, which disables the timer. The Inter-Scan Timer is valid in both continuous and triggered modes of operations. You can use the Inter-Scan Timer to:

• provide a delay between decodes to enable multiple labels, that are not necessarily unique, to be read within the same package • enable multiple decodes of the same label for verification purposes The Inter-Scan Timer accepts a value between 10 and 9999.➀ Important: To ensure that package labels are read before the No-Read Timer expires, set the Inter-Scan Timer to a value that is less than the No-Read Timer setting. A valid read starts the timer. See Figure 5.2. The decoder decodes a scan within Field #1, which starts the Inter-Scan Timer and immediately stops decoding. The decoder waits for the timer to expire (or timeout) to resume decoding. Use the following equations to create a delay between decodes: Equation 1:

Minimum Inter-Scan Timer Value W (cm or inches) x 1000 (msec/sec) Line Speed (cm/sec or inches/sec)

Equation 2:

= Approximate Inter-Scan Timer Value (msec)

Maximum Inter-Scan Timer Value S (cm or inches) x 1000 (msec/sec) = Approximate Inter-Scan Timer Value (msec) Line Speed (cm/sec or inches/sec)

You may have to experiment with several settings since factors such as label quality determine when the first read occurs.

➀ ATTENTION: Set output durations in multiples of 5 milliseconds. Actual output will have a worst-case precision of +0 to –5 milliseconds, varying with the timing of the output. Durations that are not set in multiples of 5 milliseconds will be rounded up to the nearest multiple of 5 and function within the same +0 to –5 millisecond precision. For example, a setting of 25 milliseconds will result in a duration of from 20 to 25 milliseconds. A setting of 23 milliseconds will result in the same duration range.

Publication 2755-833

Page 94

7–6

Configuration: Scanner Control, Primary Match Table, Discrete I/O

Figure 7.2 Inter-scan timer Direction of Travel Field #2

Scan Line

Field #1

W

W = Width of label.

D

D = Distance traveled during Inter-Scan Timer. S = Distance between start of field #1 field #2.

S

The label orientation must be such that distance D is ≤ S for the scanner to scan all of Field #2. The line speed must be constant. Set the Inter-Scan Timer to a value between the minimum and maximum values to prevent additional decodes of Field #1, while allowing all of Field #2 to be scanned. To allow multiple reads of a single symbol for verification purposes, set the Inter-Scan Timer to a value that is less than equation 1. Capture Count Field Type Options Select/Edit

1 through 8, or V 2

Specifies the number of identical valid scans that must be decoded before a read is considered valid. The default is 2, which means the capture count is not satisfied until two sequential, identical, valid scans are decoded. A capture count of 2 is appropriate for most applications. To specify a different capture count, select a value between 1 and 8, or V. V (for Verify) requires that each symbol in a bar code must match an entry in the primary match code table to produce a valid read. The “V” capture count is useful in high speed verification applications, where the value of the symbol is known. By loading the expected value into a match code table, the decoder only needs to acquire one valid scan matching the expected values to produce a valid read.

Publication 2755-833

Page 95

Configuration: Scanner Control, Primary Match Table, Discrete I/O

7–7

The decoder interprets a scanned label in one of three ways.

• Valid Scan Sufficient valid symbols have been decoded to satisfy the Symbols/Scan parameter. • Undecodable Scan The scanned data does not correspond to a valid pattern within the selected symbologies. • Misread or Substitution Error Smudges, stray marks, voids, or print errors (resulting in wider or narrower bars and spaces) may result in a pattern that is valid within an enabled symbology that is not representative of the intended data. The capture count reduces misreads by requiring the decoder to read labels multiple times before producing a valid read. Symbologies that are not self-checking (do not use start and stop characters or check characters) are more susceptible to misreads. For example, Interleaved 2-of-5 without check characters is not self-checking. Setting the capture count too high may result in excessive no-reads, particularly when the number of scans crossing the label in a trigger period is low (5 - 10). Set the capture count to a value no greater than half the number of expected scans crossing the label in a trigger period. Symbols / Scan Field Type Options Select/Edit

1–6, Any 1

Specifies the number of bar code symbols that must be present in a scan for a valid read. The default is 1. On a single scan (movement of laser beam from one side to another), the decoder can decode up to 6 successive bar code symbols. Valid settings for this parameter include 1, 2, 3, 4, 5, 6 or Any. If you select Any, the decoder looks for up to 6 symbols. The decoder will ignore any damaged symbols it encounters. Select Any for those applications where the number of symbols varies or cannot be controlled. For all other applications specify a number.

Publication 2755-833

Page 96

7–8

Configuration: Scanner Control, Primary Match Table, Discrete I/O

Important: If you select Any and the decoder is operating in a triggered mode, the symbols within each label must be unique. The decoder interprets identical symbols as duplicates and ignores the second symbol. Symbols/Package Field Type Options Select/Edit

1–16 1

Specifies the number of valid symbols that must be decoded to produce a valid package. The default is 1. You can enter a numeric value between 1 and 16. If the Symbols/Package setting is satisfied, a valid read occurs. If the Symbols/Package setting is not satisfied, a no-read occurs for that package as well as for each symbol not read. Match Complete Field Type Options Select/Edit

1–16 1

Specifies the number of times that symbols on a package must match entries in the match code table before a Match Complete condition occurs. You can enter a value from 1 to 16. The default is 1, which means at least one symbol on a package must match an entry in the match code table. Match Complete is one of ten output conditions that can activate an output. See the Output Condition parameter. Note: The match complete count does not have to equal the Symbols/Package setting. However, the match complete count must be less than or equal to the Symbols/Package setting for a match complete condition to occur.

Scanner B Control Parameters These parameters control the operation of Scanner B. Each parameter is defined below. The options for each parameter are summarized in a table, and explained more fully in the text. The default setting for each parameter is displayed in bold letters in the table.

Publication 2755-833

Page 97

Configuration: Scanner Control, Primary Match Table, Discrete I/O

7–9

Laser Light Refer to Laser Light under Scanner A Parameters earlier in this section for information on Scanner B laser light control. Decode Mode Field Type Options Coordinated 1 Coordinated 2 Select Package Detect Host

Sets the decode mode for Scanner B. The options are Coordinated 1, Coordinated 2, Package Detect, and Host. The default is Coordinated 1. If you set the scanning mode to either Coordinated mode, Scanner B operates in concert with Scanner A, and both scanners use the trigger specified for Scanner A. The Trigger Timeout parameters is not used when Scanner B operates in coordinated mode. If you use one of the independent decode modes (either Host or Package Detect), Scanner B will operate independently of Scanner A and use its own trigger source. If the Decode Mode is package detect; decoding is triggered by the Scanner B package detect signal. If the Decode Mode is host, decoding is initiated by the Scanner B Start Character and concluded by the Scanner B Stop Character. In the Coordinated modes, the Symbols/Package setting can be satisfied by either or both scanner(s). For example, the Symbols/Package setting is 2. Scanner A can decode one valid symbol and Scanner B can decode one valid symbol to produce a valid read, or both symbols can be read from either scanner. The difference between the two coordinated modes is in how each defines what constitutes a unique decoding event within a package.

• In Coordinated 1 mode (source dependent), the decoder always considers the source of the data as well as its content. Data will be treated as unique if it originates from different scanners, or if the value or symbology is different. • In Coordinated 2 mode (source independent), the decoder will consider data to be unique only when its value or its symbology is different. Identical data originating from different scanners will be treated as a single decode (and the second decode is ignored).

Publication 2755-833