Page 48

Installing the Decoder

4–9

Press “1” to proceed to the Symbology configuration screen. A Caution screen will appear. This screen allows you to disable the decoder’s optional output modules during configuration. It will appear each time you select a configuration screen from the Select Operations menu while the outputs are enabled. More information on this subject appears in Chapter 5. For now, press any key except ESC to continue configuration. Note: Restarting the decoder by selecting “E” from the Select Operations menu after configuration will reactivate the output modules.

At the Symbology configuration screen, we suggest resetting the decoder to assure that you are starting from a default configuration. To do so: 1. Press ESC to activate the command line at the bottom of the screen. 2. Use the arrow keys to move the highlight to the “DEFAULT’ option. 3. Press ENTER (or RETURN on some keyboards). 4. Confirm your intention to reset the decoder to its default configuration by answering yes to the confirmation prompt (press “Y” in English).

Set Symbology Parameters Enable the symbology (or symbologies) you would like to read by using the arrow keys to move the highlight to the appropriate position. Toggle through the available selections by pressing the space bar. Press ENTER to accept each change.

Publication 2755-833

Page 49

4–10

Installing the Decoder

Note: For best performance, enable only those symbologies you intend to read. You can find additional information on selecting symbologies in Chapter 6.

Configure Scanner(s) Once all your symbology selections have been made, press ESC to activate the command line at the bottom of the screen. Press ENTER to select the highlighted “Next Page”.

The Scanner Control screen will appear.

While your actual operation will vary depending on your application, you will want to follow the same basic steps during initial scanner setup. Those steps include: 1. Select the scanner based on the narrow element width (the narrowest bar or space) and desired reading distance Refer to Bar Code Site Survey (Pub. No. 2755-939) to verify all important aspects of your own application. Consult the scanner’s Product Data Sheet or User Manual for read ranges.

Publication 2755-833

Page 50

Installing the Decoder

4–11

2. Turn the decoder off and connect the scanner to the decoder 3. Even if your application will use a host computer, external display, discrete I/O (input or output devices), or package detect, do not attach those devices at this time. Figure 4.5 shows the scanners you can connect to Scanner Port A and B of the NEMA Type 1 decoder and the cables available for each scanner. Figure 4.6 shows the scanners you can connect to Scanner Port A and B of the NEMA Type 4 decoder and the cables available for each scanner. Each shows the optional package detectors connected to each scanner. Refer to the appropriate manuals for scanner mounting instructions.

Publication 2755-833

Page 51

4–12

Installing the Decoder

Figure 4.5 Connecting scanners to NEMA Type 1 decoder

SCANNER A SCANNER B

CABLES 2755-CL10 2755-CL25 2755-CL40 2755-CL50

AUX RS-232

CABLES 2755-CL10 2755-CL25 2755-CL40 2755-CL50

2755–L7/L9 Scanner

2755–L7/L9 Scanner

OR

2755-NP3/NP5

2755-NP3/NP5

Package Detector

Package Detector

Cables 2755-CK10 2755-CK25

2755–L4/L5 Scanner

OR

2755-NP1/NP4

2755-NP1/NP4

Package Detector

Package Detector

Optional Extension Cables 2755-C15D1 2755-C40D1

2755–LD4/LD8 Scanner See Photoswitch Catalog 2755-NC16 Adapter

Cables 2755-CG08 2755-CG15 2755-CG20

Publication 2755-833

OR

Optional Extension Cables 2755-C15D1 2755-C40D1

2755–LD4/LD8 Scanner

2755-G3/G6 Hand-Held Laser Scanner

OR

Cables 2755-CK10 2755-CK25

2755–L4/L5 Scanner

OR

HOST RS-232 /422 /485

See Photoswitch Catalog 2755-NC16 Adapter

OR

2755-G3/G6 Hand-Held Laser Scanner Cables 2755-CG08 2755-CG15 2755-CG20

Page 52

Installing the Decoder

4–13

Figure 4.6 Connecting scanners to NEMA Type 4 decoder

SCANNER A

CABLES 2755-CN10 2755-CN25 2755-CN40 2755-CN50

SCANNER B

AUX RS-232

HOST RS-232 /422 /485

CABLES 2755-CN10 2755-CN25 2755-CN40 2755-CN50 2755–L7/L9 Scanner

2755–L7/L9 Scanner 2755-NP3/NP5

2755-NP3/NP5

Package Detector

Package Detector

OR

OR

Cables 2755-CM10 2755-CM25

Cables 2755-CM10 2755-CM25 2755–L4/L5 Scanner

2755–L4/L5 Scanner 2755-NP1/NP4

2755-NP1/NP4

Package Detector

Package Detector

OR

OR

Optional Extension Cables 2755-C15D4 2755-C40D4 2755–LD4/LD8 Scanner See Photoswitch Catalog

Optional Extension Cables 2755-C15D4 2755-C40D4 2755–LD4/LD8 Scanner See Photoswitch Catalog

Publication 2755-833

Page 53

4–14

Installing the Decoder

4. Turn the decoder on and place a sample symbol at the desired read position. The symbol should not be moving at this time. 5. Monitor the decoder’s performance while viewing the Status and Primary Counters screen. Decoder performance is a measure of the percentage of good reads compared to the total number of read attempts. The manual you received with your scanner will instruct you on the proper implementation of pitch, tilt, and skew. When properly scanning a good quality label, your decoder performance should be at or only slightly below 100 percent. To get to the Status and Primary Counters screen, press ESC twice. The first ESC brings up the Command Line:

The second ESC brings up the Prompt Line asking if you want to save your changes to EEPROM:

Note: EEPROM is a form of retentive memory that will retain your settings even if power to the decoder is lost. Press “Y” to approve the save. When your are finished you will be at the Select Operation menu. Press “B” to open the Status and Primary Counters screen.

Publication 2755-833

Page 54

Installing the Decoder

4–15

6. Adjust the position of the scanner to maximize decoder performance. 7. Fix the scanner in this optimized position.

Customize As Required Your system is now ready to customize for best performance in your particular application. The software screens used to do that have been structured to “walk you through” the configuration process. We recommend stepping through the screens in the order they appear, using this manual as a reference. If your application requires a host device or I/O modules, the next two sections, “Connecting Host Device” and “Installing I/O Modules” will help guide you through the hardware configuration required to use them.

Connecting the AUX Terminal

The AUX port supports a terminal for either configuring the decoder or for manual data entry. The AUX port on the NEMA Type 1 decoder is configured as shown below, and communicates over an RS-232 serial communication line. It has a 25-pin D shell (female) connector. Figure 4.7 shows terminals you can connect to the AUX port of the NEMA Type 1 decoder. Figure 4.7 Connecting terminal to AUX port of NEMA Type 1 decoder

SCANNER A SCANNER B

AUX RS-232

HOST RS-232 /422 /485

①

① Construct your own cable using the pinouts in Appendix D. Supported Terminal Types Manual Data Entry

Configuration Allen-Bradley Industrial Terminals 1771-T1, -T2, -T3 Allen-Bradley 1784-T45 Laptop Terminal DEC VT100 Lear Siegler ADM 3E Computer or terminal that emulates one of the above

Publication 2755-833

Page 55

4–16

Installing the Decoder

The AUX port on the NEMA Type 4 decoder has a 19-pin (male) connector and communicates over an RS-232 serial communication line. Figure 4.8 shows terminals you can connect to the AUX port of the NEMA Type 4 decoder. Figure 4.8 Connecting terminal to AUX port of NEMA Type 4 decoder

SCANNER A SCANNER B

AUX RS-232

HOST RS-232 /422 /485

①

① Use the Cat. No. 2755-CT1 communication cable or construct your own cable using the Cat. No. 2755-NC17 Connector Kit and pinouts shown in Appendix D.

Supported Terminal Types Manual Data Entry

Allen-Bradley Industrial Terminals 1771-T1, -T2, -T3 Allen-Bradley 1784-T45 Laptop Terminal DEC VT100

Configuration

Lear Siegler ADM 3E Computer or terminal that emulates one of the above

See Appendix D for details on connecting each terminal. See Chapters 5 through 14 for details on using a terminal to configure the decoder and to monitor operations.

Connecting the Host Device

The HOST port allows the exchange of data between a host computer and the decoder. A host computer can configure the decoder, remotely control the decoder, receive messages and data from the decoder, and exchange messages with the AUX terminal. The HOST port on the NEMA Type 1 decoder is configured as shown below, and communicates over an RS-232, RS-422, or RS-485 communication line. It has a 25-pin (female) D shell connector. Figure 4.9 shows host devices you can connect to the HOST port of the NEMA Type 1 decoder.

Publication 2755-833