Page 40

Installing the Decoder Chapter Objectives

This chapter presents recommendations and instructions on how to install and connect equipment to the NEMA Type 1 and Type 4 Single and Dual-Head Bar Code Decoders. The information is organized by task, and can serve as a useful quick start tutorial to guide you through system installation and setup. Topics covered include: • meeting electrical and grounding requirements • installing alternate language LED indicator labels • mounting dimensions • connecting power cord • setting communication parameters • selecting language • selecting CRT type • selecting operations to perform • connecting and configuring scanners • setting symbology parameters • customizing setup • connecting AUX terminal • connecting host device • installing and wiring optional I/O modules

Power Requirements

Before Installation: • verify that incoming power source is 100 to 240 volts AC nominal, 50 to 60 Hz • protect power source with an external fuse or circuit breaker, rated at no more than 15 amps • connect decoder to its own branch circuit (when possible) to reduce electrical noise

Electrical Recommendations

Install equipment using guidelines in publication NFPA 70E, Electrical Safety Requirements for Employee Workplaces. In addition: • do not use signal wiring and power wiring in the same conduit • route incoming power to the decoder using a separate path from the communication cables (if paths must cross, their intersection should be perpendicular)

Publication 2755-833

Page 41

4–2

Installing the Decoder

When installing the decoder in a noise-polluted industrial environment, consider the effects of electromagnetic interference (EMI). Factors that minimize EMI include:

• proper grounding • shielded cables • correct routing of wires

Grounding

Grounding is an important safety measure in electrical installations. With solid-state systems, grounding also minimizes the effects of noise caused by electromagnetic interference (EMI). An authoritative source on grounding requirements is the National Electrical Code published by the National Fire Protection Association of Boston, Massachusetts. Article 250 discusses the types and sizes of wire conductors and safe methods of grounding electrical equipment and components.

Replacing LED Label

The NEMA Type 1 and Type 4 decoders are shipped with LED indicator labels in six different languages: English, French, German, Italian, Japanese, and Spanish. The decoders are shipped with the English label installed and a sheet of five alternate labels loosely packaged. If desired, replace the English label with another language label. To replace the LED indicator label, loosen the two screws on the decoder cover and open. The LED label insert is on the inside the cover, between the LED board and cover. Remove the insert by pulling on the gray tab. Slide the desired label into position.

Publication 2755-833

Page 42

Installing the Decoder

4–3

Figure 4.1 View of the front cover from inside

LCD Display (optional)

LED Board Pull on tab to remove LED Label insert

Mounting the Decoder

Figure 4.2 shows nominal mounting dimensions in inches (and cm) for the NEMA Type 1 and Type 4 decoders. The horizontal mounting orientation is shown here. Figure 4.2 Mounting dimensions (for reference only) 4.6 in (11.7 cm)

ALLEN-BRADLEY 10.25 in (26.0 cm) 9.5 in (24.1 cm) 8.0 in (20.3 cm)

10.5 in (26.7 cm) Mounting Holes

12.0 in (30.5 cm)

Allow clearance of 6 inches above and below decoder for cables

You can mount the decoder horizontally or vertically. When mounting allow clearance:

• at hinged side of cover for cover to swing open • of 6 inches (152 mm) above the decoder to connect cables to the scanner ports and communication ports

Publication 2755-833

Page 43

4–4

Installing the Decoder

• of 6 inches (152 mm) below the decoder to wire I/O modules and to access the power entry/power switch To mount the decoder, we recommend that you use four 1/4 inch (M6) hex-head capscrews or bolts with flat and split lockwashers and nuts. Select a bolt that equals the thickness of the mounting surface, plus the thickness of the washers, plus at least 1/2 inch (12.7 mm) to accommodate the mounting brackets of the decoder and the nut.

Installing Power Cord

The NEMA Type 1 decoder has a standard IEC 320 power entry connector. Figure 4.3 shows the available power cord options for the NEMA Type 1 decoder. Unless an alternate power cord is ordered, the decoder is shipped with a 120 VAC terminated (3 prong) U.S. power cord. Figure 4.3 Power cord options for NEMA Type 1 decoder

ON/OFF Power Switch

0

1

IEC 320 Connector

②

③

Brown (Line) Blue (Neutral) Green/Yellow (Earth Ground)

①

Black (Line) White (Neutral) Green (Earth Ground)

Power Cord Options ① 120 VAC, IEC 320 terminated (three prong) U.S. style power cord (6 ft./1.83m). Default. Shipped with decoder unless otherwise specified. ② 240 VAC, IEC 320 three wire (U.S. Color Code) unterminated power cord (6ft./1.83 m). ③ 240 VAC, IEC 320 three wire (European Harmonized Code) unterminated power cord. (UL listing/CSA approval not applicable when this cord is used.) ( 8 ft. 2 in./2.5 m)

!

ATTENTION: Disconnect incoming power and make sure the power switch on the decoder is in the off position before connecting power cord to power source.

The NEMA Type 4 decoder has a standard 3-pin power connector with a separate ON/OFF toggle switch.

Publication 2755-833

Page 44

Installing the Decoder

4–5

Figure 4.4 shows the available power cord options for the NEMA Type 4 decoder. Unless an alternate power cord is ordered, the decoder is shipped with a 120/240 VAC, three wire (U.S. Color Code) unterminated power cord. Figure 4.4 Power cord options for NEMA Type 4 Decoder

Ground 1

0

Line

ON/OFF Toggle Switch

Neutral

Power Connector

①

②

Black (Line) White (Neutral) Green (Earth Ground)

Brown (Line) Blue (Neutral) Green/Yellow (Earth Ground)

Power Cord Options ① 120/240 VAC three wire unterminated power cord (U.S. color code) 6 ft./1.83 m length. Default. Shipped with decoder unless otherwise specified. ② 240 VAC, three wire unterminated power cord (European Harmonized Code) 6 ft./1.83 m. Note: UL listing/CSA approval not applicable when this cord is used.

!

ATTENTION: Disconnect incoming power and make sure the power switch on the decoder is in the off position before connecting power cord to power source.

Publication 2755-833

Page 45

4–6

Installing the Decoder

Quick Start for DS/DD Decoder Configuration and Scanner Setup

You will need a computer terminal or a personal computer with terminal emulation software (such as PROCOMM) and an RS-232 cable. Lists of compatible terminals appear in Figures 4.7 and 4.8. Wiring information appears in Appendix D. See Chapters 5 through 14 for more detail on using a terminal to configure the decoder and monitor operations.

Connect AUX Terminal Connect your terminal’s RS-232 serial port to the AUX port of the 2755-DS or -DD decoder➀ To make easy connection to the NEMA Type 4 decoders, a 3.03 meter (10 foot) cable is available (Cat. No. 2755-CT1).

Set Communication Parameters Set the terminal’s serial port parameters to 9600 Baud, 8 Data Bits, 1 Stop Bit, No Parity (Parity = None).

Apply Power and Select Language Turn the decoder on. The decoder will send the Select Language screen to the terminal. If the screen does not appear, then press the ESC key on your terminal. The Communications LED on the decoder should light momentarily, and the decoder will resend the Select Language screen. If the LED does not light when you press ESC, verify the terminal’s communications settings and all connections.

➀ The AUX port supports a terminal for either configuring the decoder or for man entry. For information on use of the AUX port for manual data entry, consult Cha

Publication 2755-833

Page 46

Installing the Decoder

4–7

Note: When using the 2755-CT1 cable to interface with a NEMA Type 4 decoder, it may be necessary to use a null modem adapter on some computers or terminals. You can identify such equipment by comparing the pinout supplied with your computer or terminal with the schematic supplied with your cable. You will need a null modem if pins 2 and 3 are reversed. Choose a language from the Select Language screen by pressing the appropriate number on your keyboard. All of the screens that follow will now be displayed in the language you select.

Select CRT Type After you have selected a language, the Select CRT Type screen will appear on your terminal. Select a terminal type from among those listed.

Publication 2755-833

Page 47

4–8

Installing the Decoder

Note: If the next screen that appears is not properly formatted, or if strange characters appear, press the ESC key to return to the Select CRT Type screen. Review your CRT Type selection. If you are using terminal emulation, verify that your settings are correct.

Select Operations After you have selected a CRT type, you will see the Select Operations menu.

Publication 2755-833