The text of a manual · part 13 of 42
DS/DD Series B Enhanced Bar Code Decoders User Manual (Bulletin 2755): 7 - Configuration: Scanner Control, Primary Match Table, Discrete I/O, pages 107 to 113
Pages 107 to 113 of 361, from DS/DD Series B Enhanced Bar Code Decoders User Manual (Bulletin 2755)
The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 2755-DD and Allen-Bradley 2755-DS
Page 107
Configuration: Scanner Control, Primary Match Table, Discrete I/O
7–19
The corresponding output counter increments each time the buffer overflow condition occurs. AutoLoad
Configures the specified output to load bar code data from the first valid package(s) into the match code table. After configuring one or more outputs for AutoLoad, you can activate AutoLoad in one of three ways: 1. Restart system (using Select Operation menu or host command). Refer to the examples for additional information. 2. Configure Output 8 for AutoLoad (INPUT) and apply the appropriate input voltage to the input module in I/O location 8. See AutoLoad (INPUT) and Appendix H. 3. Connect a normally opened (N.O.) contact to specific pins in the AUX connector as shown in Appendix H. The AutoLoad function activates when the contacts close. Note: This method does not require an I/O Module Board with an installed input module. Note: The first Autoload does not increment the counter. After activating the AutoLoad function, and if the Symbology parameter is set to Any, then bar code fields (32 characters maximum) are sequentially loaded into the match code table until one of the following occurs:
• Symbols/Package setting is satisfied. If the number of outputs configured for AutoLoad is greater than the symbols/package setting, the Autoload function will fill entries until the symbols/package setting is satisfied. See AutoLoad (INPUT), below, for an explanation of how to load match code data into the table where the number of match codes is greater than the value of the Symbols/Package parameter.
• All entries (configured for AutoLoad) are filled. NOTE: If the Symbology parameter is set to anything other than Any, then only symbols of the currently selected symbology will be AutoLoaded.
Publication 2755-833
Page 108
7–20
Configuration: Scanner Control, Primary Match Table, Discrete I/O
If an invalid operation occurs (decoder is unable to decode a symbol in a package), it will wait for the next package. For each match code entry, the decoder:
• if Symbology is Any, the decoder changes the setting of the Symbology parameter to match the symbology of the first symbol read
• loads the match code string • changes output condition to Match-Entry If the bar code data contains the ”%” character, the decoder displays %% in the match code table, but records a single % in the data. Use the ”%” character to enter any non-printable character. For example, %M represents CTRL-M, or carriage return. See Appendix I.
!
ATTENTION: It is good practice to save your configuration once the required AutoLoad parameters have been set. Doing so assures you will retain key AutoLoad parameters even after lengthy periods without power.
AutoLoad (INPUT) Configures discrete input/output 8 for AutoLoad (INPUT). This function requires an input module in position 8 of the I/O Module Board, or connection of the appropriate pins on the AUX port. (Appendix H shows how to wire the input module in I/O location 8 to a normally open contact.) Important: AutoLoad (INPUT) requires that you configure one or more of the other outputs (1-7) for AutoLoad. You can restore the AutoLoad condition to outputs configured (and saved) for Autoload by applying the appropriate input voltage to module 8. Refer to Chapter 4 for more information. The AutoLoad (INPUT) condition serves two functions: 1. Activates AutoLoad Activates the AutoLoad function without restarting the system (via the Select Operation menu or host command). Refer to the examples for more information
Publication 2755-833
Page 109
Configuration: Scanner Control, Primary Match Table, Discrete I/O
7–21
2. AutoLoads Multiple Packages Loads multiple packages into the match code table as long as AutoLoad (INPUT) is held active. If the number of outputs configured for AutoLoad exceeds the Symbols/Package setting, multiple packages can be loaded until all table entries are filled. Do not use in Continuous Decode mode unless your intention is to load multiple versions of the same package. When Output 8 is configured for AutoLoad (INPUT), the decoder will not load data into entry 8 of the match table. AutoLoad (INPUT) is useful in product verification applications, where you need to load new match codes into the decoder regularly or when multiple packages must be used to fill the table. A switch or push button can be used to enter new product label data in the match code table. Output Duration Field Type Options Edit
10 to 9999 0
Specifies the length of time (in milliseconds) that an output is activated. Enter a value between 10 and 9999.➀ The default of 0 disables the timer. Important: The pulsed outputs will not operate unless you specify an output duration. The LED indicator for an output lights only when the output is in its closed state. Therefore, the LED for a normally open output lights when the output is closed. The LED for a normally closed output lights when the output is in its closed state and turns off when the output is opened.
➀ ATTENTION: Set output durations in multiples of 5 milliseconds. Actual output will have a worst-case precision of +0 to –5 milliseconds, varying with the timing of the output. Durations that are not set in multiples of 5 milliseconds will be rounded up to the nearest multiple of 5 and function within the same +0 to –5 millisecond precision. For example, a setting of 25 milliseconds will result in a duration of from 20 to 25 milliseconds. A setting of 23 milliseconds will result in the same duration range.
Publication 2755-833
Page 110
7–22
Configuration: Scanner Control, Primary Match Table, Discrete I/O
Figure 7.3 AutoLoad using System Restart AutoLoad Configuration at System Restart (Saved configuration)
Output duration must be set for outputs and LEDs to operate.
First Valid Package Read
Notes: AutoLoad is set for Outputs 1, 2, and 3 and applies to match code entries 1, 2, and 3. Symbols/package parameter is set to 3. After System Restart
Notes: Bar code data loaded into match code table for entries 1,2 and 3. Output condition changes from AutoLoad to Match Entry for Outputs 1, 2, and 3. The AutoLoad condition for outputs 1, 2, and 3 is still saved. System Restart No new data scanned
Notes: Table is restored to saved configuration Data cleared from primary match code table for entries 1, 2, and 3. Output conditions change from Match Entry to AutoLoad for Outputs 1, 2, and 3. Ready for Next AutoLoad (using System Restart)
Publication 2755-833
Page 111
Configuration: Scanner Control, Primary Match Table, Discrete I/O
7–23
Figure 7.4 AutoLoad using AutoLoad (INPUT) AutoLoad Configuration at AutoLoad (Input) (Saved Configuration)
Output duration must be set for outputs and LEDs to operate.
Notes: AutoLoad is set for outputs 1, 2, and 3 and applies to match code entries 1, 2, and 3. Output 8 is set to AutoLoad (INPUT), which activates the AutoLoad function for entries 1, 2, and 3 when an input signal is momentarily applied. Symbols per package parameter is set to 1.
First Valid Package Read
After AutoLoad
Notes: Bar code data loaded into match code table entry 1. Output condition changes from AutoLoad to Match Entry for Output 1. The output condition for outputs 2 and 3 does not change from AutoLoad since Symbols/Package setting has been satisfied.
AutoLoad Configuration after Next AutoLoad (INPUT) No new data scanned
Notes: Table is restored to saved configuration. Output condition changes from Match Entry to AutoLoad for Output 1.
Ready to Autoload next symbol read into match code table
Publication 2755-833
Page 112
7–24
Configuration: Scanner Control, Primary Match Table, Discrete I/O
Figure 7.5 Loading multiple packages using AutoLoad (INPUT) AutoLoad Configuration at AutoLoad (Input) (Saved Configuration)
Output duration must be set for outputs and LEDs to operate.
Notes: AutoLoad is set for Outputs 1, 2, and 3 and applies to match code entries 1, 2, and 3. Output 8 is set to AutoLoad (INPUT) and activates the AutoLoad function for entries 1, 2, and 3 when an input signal is applied. In this example, the input signal is applied until all three symbols are read. Symbols/package parameter is set to 1.
AutoLoad (INPUT) Activated and Held First Valid Package Read
Notes: Bar code data loaded into match code table entry 1. Output condition changes from AutoLoad to Match Entry for Output 1. The condition for Outputs 2 and 3 does not change since Symbols/Package has been met.
AutoLoad (INPUT) Held Active Second Valid Package Read
Notes: Bar code data from next package loaded into table entry 2. Output condition changes from AutoLoad to Match Entry for output 2. The condition for Output 3 does not change since the Symbols/Package setting has been met.
Publication 2755-833
Page 113
Configuration: Scanner Control, Primary Match Table, Discrete I/O
7–25
Figure 7.5 (continued) AutoLoad (INPUT) Held Active Third Valid Package
Notes: Bar code data from next package loaded into table entry 3. Output condition changes from AutoLoad to Match Entry for Output 3.
After AutoLoad AutoLoad (INPUT) No Longer Active
Notes: Bar code data from three packages now loaded into table. Conditions for Outputs 1, 2, and 3 show Match Entry. After all the table entries are loaded, AutoLoad (INPUT) must be disabled and re-enabled to load additional packages.
AutoLoad Configuration after AutoLoad (INPUT) Activated Again No new data scanned
Notes: Table is restored to previously saved configuration. Data cleared from match code table for entries 1, 2, and 3. Output conditions change from Match Entry to AutoLoad for Outputs 1, 2, and 3
Ready to Autoload next symbol read into match code table
Publication 2755-833