Intermec system manual for the 502X Data Collection PC family (5020, RF 5020 and 5023), portable hand-held computers running Windows CE. It explains configuring and networking the unit, the Control Panel, the Unit Manager tools for files, processes and applications, developing and installing applications with the Intermec SDK, HTML and ActiveSync, and gives full reader and configuration command references, default settings and ASCII charts. This version adds 5020 Release 3.0 firmware.
Its parts
- Introducing the 502X Data Collection PC
- Configuring and Connecting the 502X
- Customizing the 502X Using the Control Panel
- Using Unit Manager
- Developing and Installing Applications
- Reader Command Reference
- Configuration Command Reference
From the manual
Key facts from this manual
Each line names its page in the PDF.
Intermec's system manual (P/N 071479) for the 502X Data Collection PC family, which covers both the 5020 and the 5023. It explains how to configure the computers and connect them to wired or RF networks, manage them remotely with Unit Manager and SNMP, develop and install applications, and use the reader and configuration commands.
- Device
- Portable hand-held data collection computers (5020 and 5023) built on Microsoft Windows CE p. 23
- Operating system
- 5020: Windows CE 3.0; 5023: Windows CE 2.12 p. 25
- Card slots
- Basic 5020: one PC card slot for Type I or Type II 16-bit memory and I/O cards, plus one compact flash slot p. 23
- Radio
- RF 5020: WLI-F 2.4 GHz OpenAir frequency hopping radio or IEEE 802.11b High Rate (HR) direct sequence radio, with adjustable antenna p. 23
- 5020 options
- 5020: integrated scanner (standard, long-range, high-density or high-visibility) or tethered scanner port; full alphabetic or standard multifunction keypad; western European keypads; Asian character sets p. 23
- Serial connection
- The IrDA port becomes an RS-232 serial port with an L5020 Serial Communications Adapter, a D5020 Communications Dock, or (batch 5020 only) a serial I/O PC card p. 37
- Network protocols
- TCP/IP (enabled as shipped) or Intermec UDP Plus through a DCS 30X; DHCP enabled automatically p. 35, 36
- 5023
- 5023: SmartCard reader, 802.11b HR radio with adjustable antenna, scanner trigger in the built-in handle p. 23
- Languages
- U.S. language components on all 502X units; 5020: western European language fonts, and Chinese, Japanese or Korean character sets available p. 25
- Installed software
- ADC server, Configuration, Fast Config, HTTP server, Intermec SDK library functions, Internet Explorer browser, PC Connection, radio drivers, SNMP, Unit Manager for PlanNET, Varadero p. 24, 25
- Firmware
- Manual revision 002 (8/01) covers 5020 Release 3.0 firmware: IDRS and Symbology Identifier commands, Unit Manager for PlanNET p. 3
- SNMP
- Proprietary MIBs intermec.mib, itcadc.mib, itcfile.mib, itcnetwork.mib, itcsnmp.mib, itcterminal.mib; seven read-only MIB II OIDs; Intermec base OID 1.3.6.1.4.1.1963 p. 33, 34
- SDK
- Intermec 502X SDK on the Windows CE/Pocket PC Developer's Kit CD-ROM (Part No. 069511) p. 95
- Related manuals
- This manual P/N 071479; 5020 User's Manual Part No. 068975; 5023 User's Manual Part No. 070698 p. 1, 26
What this manual walks you through
- Configuring the 502X with Fast Config, the Configuration application, bar code labels or Control Panel applets p. 29, 30, 31, 32
- Configuring the 502X from an SNMP management station p. 33, 34
- Connecting the 502X to a wired or RF network and setting network parameters p. 35, 36, 37
- Managing the 502X remotely with the Unit Manager applications p. 25, 26
- Developing applications with the Intermec SDK and installing them p. 95, 96
- Using reader commands and Accumulate mode p. 123
- Configuration command reference and default configuration values p. 26
Good to know
- Keep all components with antennas at least 30 cm (1 foot) apart when power is applied, or equipment may be damaged. p. 36
- Restore Factory Defaults resets all network parameters and may cut network communications; a warm boot may be needed afterward. p. 31
- On a DCS 30X network, UDP Plus must be enabled on the 502X. p. 35
- With 011X access points, the host's ARP table may need a static entry for the 502X IP and MAC address. p. 37
Questions this manual answers
What version of Windows CE does the Intermec 5020 run?
The 5020 ships with Windows CE 3.0; the related 5023 ships with Windows CE 2.12. p. 25
What radio does the RF Intermec 5020 use?
Either a WLI-F 2.4 GHz OpenAir frequency hopping radio or an IEEE 802.11b High Rate direct sequence radio, with an adjustable antenna. p. 23
How do I get an RS-232 serial port on the 5020?
The IrDA port is converted to RS-232 with an L5020 Serial Communications Adapter, a D5020 Communications Dock, or, on a batch 5020, a serial I/O PC card. p. 37
What do I need to develop applications for the 5020?
A Pentium 266 MHz or faster PC with Windows NT 4.0 or newer, eMbedded Visual Tools 3.0, ActiveSync 3.1, and the Intermec 502X SDK for the unique 502X interfaces. p. 95
Does the 5020 support DHCP?
Yes. DHCP is enabled automatically; without a DHCP server you disable it and set the network parameters by hand. p. 36
Contents
Chapters and sections
Each line opens the PDF at its page.
- Before You Begin15
- Chapter 1: Introducing the 502X Data Collection PC21
- Chapter 2: Configuring and Connecting the 502X27
- Chapter 3: Customizing the 502X Using the Control Panel39
- Chapter 4: Using Unit Manager57
- Chapter 5: Developing and Installing Applications93
- Hardware and Software You Need to Develop Applications95
- Using the Intermec SDK to Develop Applications96
- Developing Applications Without the Intermec SDK100
- Developing Applications With HTML101
- Creating an Application Package104
- Installing and Uninstalling Applications106
- Using ActiveSync111
- Setting Up eMbedded Visual Tools 3.0 for Remote Access117
- installing and Removing Commercial Off-the-Shelf Software120
- Chapter 6: Reader Command Reference121
- Chapter 7: Configuration Command Reference129
131 more lines, from page 135 on
- Configuration Commands Listed by Bar Code Syntax135
- Entering Variable Data in a Configuration Command137
- 502X IP Address138
- Access Point Density139
- Access Point MAC Address140
- Access Point Name (5020 only)140
- Access Point Network Name141
- Acknowledgement Delay Lower Limit141
- Acknowledgement Delay Upper Limit142
- Automatic Shutoff143
- Beep Duration (5020 only)144
- Beep Frequency (5020 only)146
- Codabar148
- Code 11 (5020 only)149
- Code 16K (5020 only)151
- Code 2 of 5152
- Code 39154
- Code 49 (5020 only)158
- Code 93/93i160
- Code 128161
- Controller Connect Check Receive Timer163
- Controller Connect Check Send Timer164
- Controller IP Address165
- Decode Priority (5020 only)165
- Decode Security168
- Default Router169
- Device Name170
- DHCP (Obtain IP Address Via DHCP)171
- Display Backlight Level172
- Display Backlight Timeout172
- Domain (5020 only)174
- IDRSEnable (5020 only)175
- IDRSRetries (5020 only)175
- IDRSScope (5020 only)176
- IDRSServerAddr (5020 only)176
- IDRSTimeout (5020 only)177
- IE Autodial Name177
- IE Cache Size178
- IE Function Key URLs178
- IE Home Page179
- IE Proxy Server Address179
- IE Proxy Server Port180
- IE Underline Links180
- IE Use LAN (No Auto Dial)181
- IE Use Proxy Server182
- Inactivity Timeout (5020 only)182
- Interleaved 2 of 5183
- IrDA Baud Rate185
- Keypad Caps Lock186
- Keypad Clicker187
- Maximum Retries188
- Maximum Sleep Duration188
- MSI189
- Network Loopback191
- Network Name191
- Network Port192
- PDF 417193
- Plessey (5020 only)194
- Postamble195
- Power Management197
- Preamble197
- Primary DNS Server199
- Primary/Station Radio ROM Version200
- Primary WINS Server200
- Radio Description201
- Radio MAC Address201
- Radio ROM Version (5020 only)202
- Receive All Multicasts202
- Reservation Threshold203
- Roaming Allowed (5020 only)204
- Scanner Mode (5020 only)205
- Scanner Redundancy206
- Scanner Selection (5020 only)207
- Scanner Timeout209
- Scanner Trigger210
- Secondary DNS Server211
- Seconday WINS Server212
- Security Identification (5020 only)213
- SNMP Identification Contact214
- SNMP Identification Location214
- SNMP Identification Name215
- SNMP Security Encryption Key215
- SNMP Security IP Address216
- SNMP Security Read Encryption217
- SNMP Security Read-Only Community String217
- SNMP Security Read/Write Community String218
- SNMP Security Subnet Mask218
- SNMP Security Write Encryption219
- SNMP Trap Authentication220
- SNMP Trap Community Name220
- SNMP Trap IP Address221
- SNMP Trap Port222
- SNMP Trap Threshold222
- Speaker Volume223
- Station Name224
- Subnet Mask224
- Supported WEP225
- Symbology Identifier (5020 only)226
- TCP/IP Extensions Delayed Acknowledgement Timer231
- TCP/IP Extensions Initial Roundtrip Time231
- TCP/IP Extensions Receive Window Size232
- TFTP Resend Limit233
- TFTP Timeout233
- Transmit Mode (5020 only)234
- Transmit Rate235
- UDP Plus Enable235
- UPC/EAN236
- Virtual Wedge240
- Virtual Wedge Code Page240
- Virtual Wedge Grid241
- WEP Encryption243
- WEP Key244
- WEP Key Length245
- WEP Transmit Key245
- Appendix A: 502X Default Configuration247
- Appendix B: Full ASCII Charts255
- Appendix C: Extending the Unit Manager Main Menu265
- Appendix D: Extending the Configuration Applications277
- Index297
The whole text · 33 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 41-4
- Contents, pages 5 to 125-12
- Contents, pages 13 to 2013-20
- Chapter 1: Introducing the 502X Data Collection PC21-26
- Chapter 2: Configuring and Connecting the 502X27-38
- Chapter 3: Customizing the 502X Using the Control Panel, pages 39 to 4739-47
- Chapter 3: Customizing the 502X Using the Control Panel, pages 48 to 5648-56
- Chapter 4: Using Unit Manager, pages 57 to 6557-65
- Chapter 4: Using Unit Manager, pages 66 to 7466-74
- Chapter 4: Using Unit Manager, pages 75 to 8375-83
- Chapter 4: Using Unit Manager, pages 84 to 9284-92
- Chapter 5: Developing and Installing Applications, pages 93 to 10293-102
- Chapter 5: Developing and Installing Applications, pages 103 to 112103-112
- Chapter 5: Developing and Installing Applications, pages 113 to 120113-120
- Chapter 6: Reader Command Reference121-128
- Chapter 7: Configuration Command Reference, pages 129 to 138129-138
- Chapter 7: Configuration Command Reference, pages 139 to 148139-148
- Chapter 7: Configuration Command Reference, pages 149 to 158149-158
- Chapter 7: Configuration Command Reference, pages 159 to 168159-168
- Chapter 7: Configuration Command Reference, pages 169 to 178169-178
- Chapter 7: Configuration Command Reference, pages 179 to 188179-188
- Chapter 7: Configuration Command Reference, pages 189 to 198189-198
- Chapter 7: Configuration Command Reference, pages 199 to 208199-208
- Chapter 7: Configuration Command Reference, pages 209 to 218209-218
- Chapter 7: Configuration Command Reference, pages 219 to 228219-228
- Chapter 7: Configuration Command Reference, pages 229 to 238229-238
- Chapter 7: Configuration Command Reference, pages 239 to 246239-246
- Appendix A: 502X Default Configuration247-254
- Appendix B: Full ASCII Charts255-264
- Appendix C: Extending the Unit Manager Main Menu265-276
- Appendix D: Extending the Configuration Applications, pages 277 to 286277-286
- Appendix D: Extending the Configuration Applications, pages 287 to 296287-296
- Index297-310
The file