Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 25 of 33

502X Data Collection PC System Manual: Chapter 7: Configuration Command Reference, pages 219 to 228

Pages 219 to 228 of 310, from 502X Data Collection PC System Manual

The original document is the PDF (2.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 5020

Page 219

Configuration Command Reference

7

SNMP Security Subnet Mask (continued)

Configuration:

Use one of these methods: Configuration

On Cold Boot: SNMP OID:

Applications

SNMP

Bar Codes

Fast Config

No

Yes

No

No

Not saved 1.3.6.1.4.1.1963.10.5.1.1.1.2.index where index is the SNMP security IP address.

Options:

The SNMP Security Subnet Mask must be a valid IP address in the form x.x.x.x where x is a value between 0 and 255. Default:

None

SNMP Security Write Encryption Purpose:

Sets the packet-level mode of security for SNMP read/write requests. If you enable write encryption, all SNMP packets received with the read/write community string have to be encrypted or the packet will not be authorized. You need to use Intermec-provided software that supports encryption. To enable security encryption, you also need to set the encryption key. For help, see “SNMP Security Encryption Key” earlier in this chapter.

Configuration:

Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

No

No

In the Configuration or Configuration Management application, choose Configure and then SNMP. Next, choose Security and then choose Write Encryption. On Cold Boot: SNMP OID:

Not saved 1.3.6.1.4.1.1963.10.5.1.5.0

7-91

Page 220

502X Data Collection PC System Manual

SNMP Security Write Encryption (continued)

Options:

Acceptable values for the write encryption are: 1 2

Default:

On - SNMP packets must be encrypted Off - SNMP packets do not have to be encrypted

Off

SNMP Trap Authentication Purpose:

Configuration:

This command determines whether or not authentication traps are sent. If trap authentication is enabled, an authentication trap is sent if an SNMP packet is received by the master agent and the community string is not valid. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

No

No

In the Configuration or Configuration Management application, choose Configure and then SNMP. Next, choose Traps and then choose Authentication. On Cold Boot: SNMP OID: Options:

Not saved 1.3.6.1.4.1.1963.10.5.2.2.0 Acceptable values for the trap authentication are: 1 2

Default:

On Off

On

SNMP Trap Community Name Purpose: Configuration:

The community name is attached to a trap that is sent to this trap destination. Use one of these methods: Configuration

7-92

Applications

SNMP

Bar Codes

Fast Config

No

Yes

No

No

Page 221

Configuration Command Reference

7

SNMP Trap Community Name (continued)

On Cold Boot: SNMP OID:

Not saved 1.3.6.1.4.1.1963.10.5.2.1.1.3.index where index is the SNMP trap IP address.

Options:

The community name can be up to 128 ASCII characters.

Default:

NULL

SNMP Trap IP Address Purpose:

Configuration:

The SNMP Trap IP address is the IP address to which the 502X will send traps. If no trap IP address is set, the 502X will accept SNMP requests from any source. You can set multiple combinations of valid trap IP addresses, trap ports, and trap community names so that the 502X will accept SNMP requests from multiple sources. Use one of these methods: Configuration

On Cold Boot: SNMP OID:

Applications

SNMP

Bar Codes

Fast Config

No

Yes

No

No

Not saved 1.3.6.1.4.1.1963.10.5.2.1.1.1.index where index is the SNMP trap IP address.

Options:

The SNMP Trap IP address must be a valid IPv4 address that has the form y.x.x.x where y is a value between 1 and 223 (not including 127) and x is a value between 0 and 255. Default:

None

7-93

Page 222

502X Data Collection PC System Manual

SNMP Trap Port Purpose: Configuration:

The port through which the trap packet is sent and received. Use one of these methods: Configuration

On Cold Boot: SNMP OID:

Applications

SNMP

Bar Codes

Fast Config

No

Yes

No

No

Not saved 1.3.6.1.4.1.1963.10.5.2.1.1.2.index where index is the SNMP trap IP address.

Options:

The trap port can be any number from 1 to 65535.

Default:

162

SNMP Trap Threshold Purpose:

Configuration:

The trap threshold determines the maximum number of traps per second that the master agent generates. If the threshold is reached, the trap will not be sent. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

No

No

In the Configuration or Configuration Management application, choose Configure and then SNMP. Next, choose Traps and then choose Threshold. On Cold Boot:

7-94

Not saved

SNMP OID:

1.3.6.1.4.1.1963.10.5.2.3.0

Options:

Any positive integer value.

Default:

10

Page 223

Configuration Command Reference

7

Speaker Volume Purpose:

Configuration:

Adjusts the volume of the 502X’s audio signals. Set the speaker volume according to operator preference and work environment. For more information, see “Understanding the Audio Signals” in Chapter 1 of your user’s manual. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

Yes

No

In the Configuration or Configuration Management application, choose Configure and then Unit. Next, choose Speaker and then choose Volume. On Cold Boot: SNMP OID: Syntax:

Not saved 1.3.6.1.4.1.1963.15.3.1.3.0 BVdata You only use the two-character command BV for bar code configuration labels. Acceptable values for data are: 0 1 2 3 4 5

Default: Scan:

Off Very quiet Quiet Normal Loud Very loud

Normal One of these bar codes: Beep Volume Off

Beep Volume Very Quiet

*$+BV0*

*$+BV1*

Beep Volume Quiet

Beep Volume Nornal

*$+BV2*

*$+BV3*

*$+BV0*

*$+BV2*

*$+BV1*

*$+BV3*

7-95

Page 224

502X Data Collection PC System Manual

Speaker Volume (continued) Beep Volume Loud

Beep Volume Very Loud

*$+BV4*

*$+BV5*

*$+BV4*

*$+BV5*

Station Name Purpose:

Configuration:

Identifies the 502X to the network. For example, you might want to define station names so that you can identify devices when using site survey tools. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

No

No

In the Configuration or Configuration Management application, choose Configure and then Network. Next, choose Radio, then Radio, and finally choose Station Name. On Cold Boot: SNMP OID:

Saved 1.3.6.1.4.1.1963.5.5.2.4.1.1.4ifindex where ifindex is the radio adapter card number.

Options:

A station name consists of up to 32 printable ASCII characters. You are advised to use the same name as the device’s name.

Default:

Intermec5020 or Intermec5023

Subnet Mask Purpose:

Defines the subnet mask, an internal TCP/IP stack variable that is used to separate the subnetwork address from the local IP address. The TCP/IP stack performs a bit-wise AND on the IP address and the subnet mask. Each address segment represents one byte, where 255 converts to FF hex. This computation is used to find out if the DCS 30X (UDP Plus) or host (TCP/IP) and 502X are on different subnetworks. If the 502X is on a different IP subnetwork than the DCS 30X or host, you must set the subnet mask. After you change this parameter, suspend and resume the 502X to make the change effective.

7-96

Page 225

Configuration Command Reference

7

Subnet Mask (continued)

For example, if the IP address is 192.9.150.184 and the subnet mask is 255.255.255.0, the subnetwork address is 192.9.150.0. Configuration:

Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

No

Yes

In the Configuration or Configuration Management application, choose Configure and then Network. Next, choose Radio or Ethernet, then IP Address, then Obtain IP Address Via DHCP, and finally choose Subnet Mask. On Cold Boot: SNMP OID:

Saved 1.3.6.1.4.1.1963.5.15.5.2.1.3.index where index is the radio or I/O adapter card number.

Options:

The subnet mask must be a valid IP address in the form x.x.x.x where x is a number from 0 to 255. Default:

0.0.0.0

Supported WEP Purpose:

Configuration:

Displays the supported WEP type (none, WEP64, or WEP128) for the installed 802.11b HR radio. Supported WEP is a read-only parameter that cannot be changed. In the Configuration or Configuration Management applications, choose Configure and then Network. Next choose Radio, then Radio, and finally choose Supported WEP.

On Cold Boot: SNMP OID:

Not applicable (read-only) 1.3.6.1.4.1.1963.5.5.2.4.1.1.8.ifindex where ifindex is the radio adapter card number.

Default:

Not applicable

7-97

Page 226

502X Data Collection PC System Manual

Symbology Identifier (5020 only) Purpose:

Enables the addition of a pre-pended symbology identifier to any scanned label data, allowing you to indicate what type of data is being sent. You can prepend one of the following types of character strings to identify which symbology the data is using: The AIM Standard symbology identifiers consist of a threecharacter structure indicating the symbology and the optional features of the symbology. For more information about the AIM standard for symbology identifiers, refer to the AIM ISO/IEC Standard. AIM ISO/IEC Standard

The user-defined symbology identifier is one to four ASCII characters in length. You can configure user-defined symbology identifiers to assign custom identifier strings to the bar code symbologies. User-defined ASCII Character String

To enable the symbology ID, you must configure up to four parameters. To set the optional third and fourth parameters, you must set the second parameter to user-defined. A user-defined symbology ID must be from one to four ASCII characters in length. Configuration:

Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

Yes

No

In the Configuration or Configuration Management application, choose Configure and then Data Collection. Next, choose Symbologies, and finally choose Identifier. On Cold Boot: SNMP OID:

7-98

Saved 1.3.6.1.4.1.1963.15.3.3.4.1.2.1

Codabar

1.3.6.1.4.1.1963.15.3.3.4.1.3.1

Code 39

1.3.6.1.4.1.1963.15.3.3.4.1.4.1

Code 93

1.3.6.1.4.1.1963.15.3.3.4.1.5.1

Code 128

1.3.6.1.4.1.1963.15.3.3.4.1.6.1

UPC-A

1.3.6.1.4.1.1963.15.3.3.4.1.7.1

UPC-E

1.3.6.1.4.1.1963.15.3.3.4.1.8.1

EAN8

1.3.6.1.4.1.1963.15.3.3.4.1.9.1

EAN13

1.3.6.1.4.1.1963.15.3.3.4.1.10.1

I 2 of 5

1.3.6.1.4.1.1963.15.3.3.4.1.11.1

MSI

1.3.6.1.4.1.1963.15.3.3.4.1.12.1

PDF 417

Page 227

Configuration Command Reference

7

Symbology Identifier (continued)

Syntax:

1.3.6.1.4.1.1963.15.3.3.4.1.13.1

Plessey

1.3.6.1.4.1.1963.15.3.3.4.1.14.1

Straight 2 of 5 2 Bar SS

1.3.6.1.4.1.1963.15.3.3.4.1.15.1

Straight 2 of 5 3 BarSS

1.3.6.1.4.1.1963.15.3.3.4.1.16.1

Code 11

1.3.6.1.4.1.1963.15.3.3.4.1.17.1

Code 49

1.3.6.1.4.1.1963.15.3.3.4.1.18.1

Code 49 FC1

1.3.6.1.4.1.1963.15.3.3.4.1.19.1

Code 49 FC2

1.3.6.1.4.1.1963.15.3.3.4.1.20.1

Code 49 FC3

1.3.6.1.4.1.1963.15.3.3.4.1.21.1

Code 16K

CYdata where data must be 3 to 8 digits selected from this list: First and second digits:

00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22-99

All symbology identifiers (SIs) Code 39 Code 128 Codabar Code 93 Code 11 Interleaved 2 of 5 Code 16K PDF 417 MSI Plessey Straight 2 of 5 (with two bar start/stop codes) Straight 2 of 5 (with 3 bar start/stop codes) Code 49 Code 49 - Function Code 1 Code 49 - Function Code 2 EAN/UPC-A EAN/UPC-E EAN/UPC-8 EAN/UPC-13 Non-bar code (RFID) SIs Code 49 - Function Code 3 System expansion SIs

Third digit:

0 1

Disable ISO/IEC Standard (Enable) Not valid if All Symbology IDs (00) is selected User-defined SI (disables ISO/IEC Standard)

2

7-99

Page 228

502X Data Collection PC System Manual

Symbology Identifier (continued)

Fourth digit (optional):

1-4

Specifies length of user-defined SI string

5th through 8th digits (optional): User-defined SI Note: When configuring symbology IDs with SNMP, do not specify the length of the user-defined SI string. Default: Scan:

Disabled To set the default configuration for symbology IDs, scan this bar code: Disable All Symbology IDs

*$+CY000* *$+CY000*

Or:

To configure symbology ID parameters for a specific symbology or to configure a user-defined symbology ID: 1. Scan this bar code: Enter Accumulate Mode / Set Symbology IDs

*+/$+CY* *+/$+CY*

2. Scan the symbology from these bar codes: Code 39

Code 128

*01*

*02*

Codabar

Code 93

*03*

*04*

Code 11

Interleaved 2 of 5

*05*

*06*

Code 16K

PDF 417

*07*

*08*

*01*

*03*

*05*

*07*

7-100

*02*

*04*

*06*

*08*