502X Data Collection PC System Manual: Chapter 7: Configuration Command Reference, pages 229 to 238

Pages 229 to 238 of 310, from 502X Data Collection PC System Manual

The original document is the PDF (2.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 5020

Page 229

Configuration Command Reference

7

Symbology Identifier (continued) MSI

*09*

Plessey

*10*

*09*

*10*

Straight 2 of 5 (with 2 bar start/stop codes)

Straight 2 of 5 (with 3 bar start/stop codes)

*11*

*12*

*11*

*12*

Code 49

Code 49 - Function Code 1

*11*

*12*

*13*

*14*

Code 49 - Function Code 2

EAN/UPC-A

*15*

*16*

*15*

*16*

EAN/UPC-E

EAN/UPC-8

*17*

*18*

*17*

*18*

EAN/UPC-13

Non-bar code (RFID) identifiers

*19* *19*

*20*

*20*

Code 49 - Function Code 3

*15* *21*

3. Scan one of these bar codes: Disable Symbology IDs

ISO/IEC Standard (Enable)

*0*

*1*

*0*

*1*

Enable User-Defined Symbology ID (Disables ISO/IEC Standard)

*2* *2*

7-101

Page 230

502X Data Collection PC System Manual

Symbology Identifier (continued)

Note: To set a user-defined symbology using the bar code labels in Appendix B, you must configure the terminal to enable Code 39 in Full ASCII mode. For help, see “Code 39” earlier in this chapter. 4. If you enabled a user-defined symbology ID, scan a numeric value for the symbology ID character length from these bar codes:

*1*

*2*

*1*

*2*

*3*

*4*

*3*

*4*

If you did not enable a user-defined symbology ID, go to Step 6. 5. Scan a value for the user-defined symbology ID from the “Full ASCII Bar Code Chart” in Appendix B. The user-defined symbology ID should be 1 to 4 characters in length, equal to the value you scanned in Step 4. 6. Scan this bar code: Exit Accumulate Mode

*-/+* *-/+*

7-102

Page 231

Configuration Command Reference

7

TCP/IP Extensions Delayed Acknowledgement Timer Purpose:

Configuration:

Specifies the time that TCP will delay an acknowledgement on the arrival of data. You can use the TCP/IP extensions commands to fine tune the network performance in a wireless networking environment. After you change this parameter, suspend and resume the 502X to make the change effective. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

No

No

In the Configuration or Configuration Management application, choose Configure and then Network. Next, choose Radio, then TCP/IP Extensions, and finally choose Delayed ACK Timer. On Cold Boot: SNMP OID:

Not saved 1.3.6.1.4.1.1963.5.15.5.3.1.3.index where index is the radio adapter card number.

Options:

Any number from 100 to 3000 ms

Default:

200 ms

TCP/IP Extensions Initial Roundtrip Time Purpose:

Configuration:

The initial roundtrip time is an average measurement of the delay between two hosts. In general, this value is greater for wireless networks than for wired networks. You can use the TCP/IP extensions commands to fine tune the network performance in a wireless networking environment. After you change this parameter, suspend and resume the 502X to make the change effective. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

No

No

7-103

Page 232

502X Data Collection PC System Manual

TCP/IP Extensions Initial Roundtrip Time (continued)

In the Configuration or Configuration Management application, choose Configure and then Network. Next, choose Radio, then TCP/IP Extensions, and finally choose Initial Round Trip Time. On Cold Boot: SNMP OID:

Not saved 1.3.6.1.4.1.1963.5.15.5.3.1.2.index where index is the radio adapter card number.

Options:

An acceptable value for the initial roundtrip time is any number from 0 to 2,147,483,647 ms.

Default:

3000 ms

TCP/IP Extensions Receive Window Size Purpose:

Configuration:

Determines the maximum TCP receive window size offered by the system. The receive window specifies the number of bytes a sender may transmit without receiving an acknowledgement. In general, larger receive windows work better with high-delay, high-bandwidth networks. For the greatest efficiency, the receive window should be an even multiple of the TCP Maximum Segment Size (MSS) and it should not exceed the system maximum. After you change this parameter, suspend and resume the 502X to make the change effective. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

No

No

In the Configuration or Configuration Management application, choose Configure and then Network. Next, choose Radio, then TCP/IP Extensions, and finally choose Receive Window Size. On Cold Boot: SNMP OID:

Not saved 1.3.6.1.4.1.1963.5.15.5.3.1.1.index where index is the radio adapter card number.

7-104

Options:

Any number from 0 to the Global Maximum TCP Window Size (default of 64K).

Default:

8192 bytes

Page 233

Configuration Command Reference

7

TFTP Resend Limit Purpose: Configuration:

The TFTP resend limit identifies the maximum number of resent data blocks during a Put to Server request. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

No

No

In the Configuration or Configuration Management application, choose Configure and then Network. Next, choose Protocols, then TFTP, and finally choose Resend Limit. On Cold Boot:

Saved

SNMP OID:

1.3.6.1.4.1.1963.10.3.3.1.11.0

Options:

Any value from 10 to 10,000.

Default:

100

TFTP Timeout Purpose: Configuration:

The TFTP timeout sets the amount of time that the 502X will wait for a response from a TFTP server. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

No

No

In the Configuration or Configuration Management application, choose Configure and then Network. Next, choose Protocols, then TFTP, and finally choose Timeout. On Cold Boot: SNMP OID:

Saved 1.3.6.1.4.1.1963.10.3.3.1.10.0

Options:

An acceptable value for the TFTP timeout is any value from 200 to 25,000 ms.

Default:

500 ms

7-105

Page 234

502X Data Collection PC System Manual

Transmit Mode (5020 only) Purpose:

Defines the transmit mode that the OpenAir radio uses. There are three modes: Binary Frequency Shift Key. A broadcasting method the radio uses that lengthens the range, but halves the throughput. This method is switched when the RF protocol on the 5020 determines that communications are degrading.

BFSK

Quad Frequency Shift Key. A broadcasting method the radio uses that shortens the range, but doubles the throughput. QFSK is the method used under standard radio conditions. QFSK

Auto

The radio automatically switches modes between BFSK and QFSK as needed.

After you change this parameter, suspend and resume the 5020 to make the change effective. Note: Even if you set this configuration command, the 5020 radio will reset the parameter as needed to maximize the broadcasting range and throughput. Configuration:

Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

No

No

In the Configuration or Configuration Management application, choose Configure and then Network. Next, choose Radio, then Radio, and finally choose Transmit Mode. On Cold Boot: SNMP OID:

Saved 1.3.6.1.4.1.1963.5.5.2.5.1.1.6.index where index is the radio adapter card number.

Options:

Acceptable values for the RF Transmit mode are: 0 1 3

Default:

7-106

Auto

BFSK (Binary Frequency Shift Key) QFSK (Quad Frequency Shift Key) Auto

Page 235

Configuration Command Reference

7

Transmit Rate Purpose:

Configuration:

Sets the bit rate for data transmission in the 802.11b HR radio. Slower transmission rates provide better range while faster rates provide better throughput. You should configure most of the terminals to the faster transmit range. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

No

No

In the Configuration or Configuration Management application, choose Configure and then Network. Next, choose Radio, then Radio, finally choose Transmit Rate. On Cold Boot: SNMP OID:

Saved 1.2.840.10036.1.1.1.11.ifindex where ifindex is the radio adapter card number.

Options:

Acceptable values (hexadecimal) for the transmit rate are: 02040B16 16 02040B 0B

Default:

11 Mbs/Fallback 11 Mbs/Fixed 5.5 Mbs/Fallback 5.5 Mbs/Fixed

11 Mbs/Fallback

UDP Plus Enable Purpose:

Configuration:

Enables or disables UDP Plus for enhanced wireless networking. You only use this command in an Intermec UDP Plus network where the 502X communicates with a host through a DCS 30X. After you change this parameter, warm boot the 502X to make the change effective. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

No

No

7-107

Page 236

502X Data Collection PC System Manual

UDP Plus Enable (continued)

In the Configuration or Configuration Management application, choose Configure and then Network. Next, choose Advanced and then choose UDP Plus Enable. On Cold Boot: SNMP OID: Options:

Saved 1.3.6.1.4.1.1963.15.501.7.3.0 Acceptable values for the UDP Plus Enable parameter are: 0 1

Default:

Disabled Enabled

Disabled

UPC/EAN Purpose:

Enables or disables the decoding of Universal Product Code (UPC)/European Article Numbering (EAN) symbology. UPC/EAN are fixed length, numeric, continuous symbologies that use four element widths. A 502X that is configured to decode EAN bar codes can decode UPC, but the reverse is not true. UPC code is a subset of EAN code. To define the UPC/EAN symbology, you set up to seven digits. The fifth, sixth, and seventh digits are optional. To set the sixth digit, you must set the fifth digit. To set the seventh digit, you must set all seven digits.

Configuration:

Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

Yes

No

In the Configuration or Configuration Management application, choose Configure and then Data Collection. Next, choose Symbologies and then choose UPC/EAN. On Cold Boot: SNMP OID:

7-108

Not saved 1.3.6.1.4.1.1963.15.3.3.1.1.6.1

Page 237

Configuration Command Reference

7

UPC/EAN (continued)

Syntax:

CEdata where data must be 4 to 7 digits selected from this list: First digit:

0 1 2

UPC-A/EAN-13 disabled UPC-A/EAN-13 enabled UPC-A only enabled

Second digit:

0 1 2

UPC-E disabled (5020) UPC-E enabled, standard format (5023) UPC-E enabled (5020 only) UPC-E enabled, expanded format

Third digit:

0 1

EAN-8 disabled EAN-8 enabled

Fourth digit:

0

(5020) Supplementals are not allowed. If a supplemental is present, an error results. (5023) Supplementals are ignored. If a supplemental is present, it is not read. Supplementals are allowed (may or may not be present). Supplementals required. If no supplemental is present, an error results. (5020 only) 2-digit supplementals required. If no supplemental is present, or if the supplemental is other than 2 digits in length, an error results. (5020 only) 5-digit supplementals required. If no supplemental is present, or if the supplemental is other than 5 digits in length, an error results.

1 2 3

4

Fifth digit:

0 1

Discard check digit Transmit check digit

Sixth digit:

0 1

Discard number system digit Transmit number system digit

Seventh digit:

0 1

Discard the leading zero for UPC-A Retain the leading zero for UPC-A

You only use the two-character command CE for bar code configuration labels. Default:

First digit: Second digit: Third digit: Fourth digit: Fifth digit: Sixth digit: Seventh digit:

UPC-A/EAN-13 enabled UPC-E enabled EAN-8 enabled Supplementals allowed Transmit check digit Transmit number system digit Retain leading zero for UPC-A

7-109

Page 238

502X Data Collection PC System Manual

UPC/EAN (continued)

Scan:

To disable UPC/EAN, scan this bar code: Disable UPC/EAN

*$+CE0000000* *$+CE0000000*

Or:

To enable UPC/EAN: 1. Scan this bar code: Enter Accumulate Mode / Enable UPC/EAN

*+/$+CE* *+/$+CE*

2. Scan one of these bar codes to set the first digit: Disable UPC/EAN-13

Enable UPC/EAN-13

*0*

*1*

*0*

*1*

Enable UPC-A Only

*2* *2*

3. Scan one of these bar codes to set the second digit: Disable UPC-E

Enable UPC-E

*0*

*1*

*0*

*1*

4. Scan one of these bar codes to set the third digit: Disable EAN-8

Enable EAN-8

*0*

*1*

*0*

*1*

5. Scan one of these bar codes to set the fourth digit: Supplementals Not Allowed (50 20) or Supplementals Ignored (5023)

*0* *0*

7-110