Page 209

Configuration Command Reference

7

Scanner Selection (continued) Internal Raster Scanner

*$+SS13* *$+SS13*

Scanner Timeout Purpose:

Configuration:

Defines the maximum length of time the scanner stays on after you press the Scan button, squeeze the scanner trigger, or activate a tethered laser scanner. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

Yes

No

In the Configuration or Configuration Management application, choose Configure and then Data Collection. Next, choose Scanner and then choose Timeout. On Cold Boot: SNMP OID: Syntax:

Not saved 1.3.6.1.4.1.1963.15.3.3.3.1.1.5.1.1 SAdata You only use the two-character command SA for bar code configuration labels. Acceptable values for data are: 0 1-60 1-99

(5020 only) Disabled (5020 only) Shutoff time in seconds (5023 only) Shutoff time in tenths of seconds

Default:

Disabled (no timeout)

Scan:

1. Scan this bar code: Enter Accumulate Mode / Set Scanner Timeout

*+/$+SA* *+/$+SA*

7-81

Page 210

502X Data Collection PC System Manual

Scanner Timeout (continued)

2. Scan a numeric value for data from these bar codes:

*0*

*1*

*2*

*3*

*0*

*1*

*2*

*3*

*4*

*5*

*4*

*5*

*6*

*7*

*6*

*7*

*8*

*9*

*8*

*9*

3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

Scanner Trigger Purpose:

Configuration:

Scanner trigger allows you to set level triggering or edge triggering. •

With level triggering, you activate the scanner and the laser turns on and stays on until you release the button or the trigger on a tethered scanner.

•

In edge triggering, you activate the scanner and the laser turns on and stays on. When you activate the scanner a second time, the laser turns off. Simply releasing the button or the trigger does not turn the laser off. If the laser is left on, the scanner timeout turns the laser off.

Use one of these methods: Configuration

7-82

Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

Yes

No

Page 211

Configuration Command Reference

7

Scanner Trigger (continued)

In the Configuration or Configuration Management application, choose Configure and then Data Collection. Next, choose Scanner and then choose Trigger Mode. On Cold Boot: SNMP OID: Syntax:

Not saved 1.3.6.1.4.1.1963.15.3.3.3.1.1.7.1.1 SCdata You only use the two-character command SC for bar code configuration labels. Acceptable values for data are: 0 1

Default: Scan:

Level triggering Edge triggering

Level triggering One of these bar codes: Enable Level Triggering

*$+SC0* *$+SC0*

Enable Edge Triggering

*$+SC1* *$+SC1*

Secondary DNS Server Purpose:

Configuration:

The IP address to which the 502X sends DNS requests when the Primary DNS Server is not responding. After you change this parameter, suspend and resume the 502X to make the change effective. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

No

Yes

In the Configuration or Configuration Management application, choose Configure and then Network. Next, choose Radio or Ethernet, then Name Servers, and finally choose Secondary DNS.

7-83

Page 212

502X Data Collection PC System Manual

Secondary DNS Server (continued)

On Cold Boot: SNMP OID:

Saved 1.3.6.1.4.1.1963.5.15.7.1.1.1.2.index where index is the radio or I/O adapter card number.

Options:

The Secondary DNS Server address must be a valid IPv4 address that has the form y.x.x.x where y is a value between 1 and 223 (not including 127) and x is a value between 0 and 255. Default:

0.0.0.0

Secondary WINS Server Purpose:

Configuration:

The IP address to which the 502X sends WINS requests when the Primary WINS Server is not responding. After you change this parameter, suspend and resume the 502X to make the change effective. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

No

Yes

In the Configuration or Configuration Management application, choose Configure and then Network. Next, choose Radio or Ethernet, then Name Servers, and finally choose Secondary WINS. On Cold Boot: SNMP OID:

Saved 1.3.6.1.4.1.1963.5.15.6.1.1.2.index where index is the radio or I/O adapter card number.

Options:

The Secondary WINS Server address must be a valid IPv4 address that has the form y.x.x.x where y is a value between 1 and 223 (not including 127) and x is a value between 0 and 255. Default:

7-84

0.0.0.0

Page 213

Configuration Command Reference

7

Security Identification (5020 Only) Purpose:

Configuration:

Defines the password you can set for secured transmission and receipt of data between devices in the OpenAir network. To communicate, all access points and 5020s in the subnetwork must have matching security IDs. After you change this parameter, suspend and resume the 5020 to make the change effective. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

No

Yes

In the Configuration or Configuration Management application, choose Configure and then Network. Next, choose Radio, then Radio, and finally choose Security ID. On Cold Boot:

Saved The security ID is stored internally in the OpenAir radio card rather than being stored in permanent memory on the 5020.

SNMP OID:

1.3.6.1.4.1.1963.5.5.2.5.1.1.9.index where index is the radio adapter card number.

Options:

The security ID can be up to 20 ASCII characters.

Default:

No characters or blank (disabled)

Notes:

If you view the RF security ID in the Configuration or Configuration Management applications, the actual security ID does not display on the screen. If you change the security ID, you see the new password until you exit the application.

7-85

Page 214

502X Data Collection PC System Manual

SNMP Identification Contact Purpose: Configuration:

This command gives you the information for the person who is responsible for this managed node or 502X. You can also set the information on how to contact this person. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

No

No

In the Configuration or Configuration Management application, choose Configure and then SNMP. Next, choose Identification and then choose Contact. On Cold Boot: SNMP OID:

Not saved 1.3.6.1.2.1.1.4.0

Options:

The identification contact may be up to 255 ASCII characters.

Default:

No characters or blank

SNMP Identification Location Purpose: Configuration:

The identification location is the physical location for this 502X. For example, the location may be “Shipping.” Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

No

No

In the Configuration or Configuration Management application, choose Configure and then SNMP. Next, choose Identification and then choose Location. On Cold Boot: SNMP OID:

7-86

Not saved 1.3.6.1.2.1.1.6.0

Options:

The identification location may be up to 255 ASCII characters.

Default:

No characters or blank

Page 215

Configuration Command Reference

7

SNMP Identification Name Purpose:

Configuration:

The identification name is the assigned name for this managed node or 502X. Usually, the name is the 502X’s fully-qualified domain name. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

No

No

In the Configuration or Configuration Management application, choose Configure and then SNMP. Next, choose Identification and then choose Name. On Cold Boot: SNMP OID:

Not saved 1.3.6.1.2.1.1.5.0

Options:

The identification name may be up to 255 ASCII characters.

Default:

No characters or blank

SNMP Security Encryption Key Purpose:

The security encryption key identifies the key that the 502X uses to encrypt or decipher SNMP packets. Encryption is used only by Intermec-provided software. If encryption is enabled, SNMP management platforms will no longer be able to communicate with the 502X. The encryption key is returned encrypted. To enable security encryption, set the encryption key and one or both of these two commands: •

SNMP Security Read Encryption

•

SNMP Security Write Encryption

For help, see “SNMP Security Read Encryption” and “SNMP Security Write Encryption” later in this chapter. Configuration:

Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

No

No

7-87

Page 216

502X Data Collection PC System Manual

SNMP Security Encryption Key (continued)

In the Configuration or Configuration Management application, choose Configure and then SNMP. Next, choose Security and then choose Encryption Key. On Cold Boot: SNMP OID:

Not saved 1.3.6.1.4.1.1963.10.5.1.6.0

Options:

The encryption key can be from 4 to 20 ASCII characters.

Default:

NULL

SNMP Security IP Address Purpose:

The security IP address is the IP address from which the 502X will accept SNMP requests. The 502X uses the security IP address and security subnet mask to determine if the SNMP request was from a valid IP address. If no security IP address is set, the 502X will accept SNMP requests from any source. You can set multiple pairs of valid security IP addresses and subnet mask addresses so that the 502X will accept SNMP requests from multiple sources. For help with the subnet mask, see “SNMP Security Subnet Mask” later in this chapter.

Configuration:

Use one of these methods: Configuration

On Cold Boot: SNMP OID:

Applications

SNMP

Bar Codes

Fast Config

No

Yes

No

No

Not saved 1.3.6.1.4.1.1963.10.5.1.1.1.1.index where index is the SNMP security IP address.

Options:

The SNMP Security IP address must be a valid IPv4 address that has the form y.x.x.x where y is a value between 1 and 223 (not including 127) and x is a value between 0 and 255. Default:

7-88

None (502X accepts SNMP requests from any IP host)

Page 217

Configuration Command Reference

7

SNMP Security Read Encryption Purpose:

Sets the packet-level mode of security for SNMP read-only requests. If you enable read encryption, all SNMP get and get next packets that are received have to be encrypted or the packet will not be authorized. If encryption is enabled, you can only use Intermecprovided software. To enable security encryption, you also need to set the encryption key. For help, see “SNMP Security Encryption Key” earlier in this chapter.

Configuration:

Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

No

No

In the Configuration or Configuration Management application, choose Configure and then SNMP. Next, choose Security and then choose Read Encryption. On Cold Boot: SNMP OID: Options:

Not saved 1.3.6.1.4.1.1963.10.5.1.4.0 Acceptable values for the read encryption are: 1 2

Default:

On - SNMP get and get next packets must be encrypted Off - SNMP packets do not have to be encrypted

Off

SNMP Security Read-Only Community String Purpose: Configuration:

The read-only community string is required so that SNMP get and get next requests can be processed by the 502X. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

No

No

In the Configuration or Configuration Management application, choose Configure and then SNMP. Next, choose Security and then choose Read Only Community String.

7-89

Page 218

502X Data Collection PC System Manual

SNMP Security Read-Only Community String (continued)

On Cold Boot: SNMP OID:

Not saved 1.3.6.1.4.1.1963.10.5.1.2.0

Options:

The read-only community string can be up to 128 ASCII characters.

Default:

public

SNMP Security Read/Write Community String Purpose:

Configuration:

The read/write community string is required so that SNMP set requests can be processed by the 502X. An SNMP packet with this name as the community string will also process SNMP get and next requests. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

No

No

In the Configuration or Configuration Management application, choose Configure and then SNMP. Next, choose Security and then choose Read/Write Community String. On Cold Boot: SNMP OID:

Not saved 1.3.6.1.4.1.1963.10.5.1.3.0

Options:

The read/write community string can be up to 128 ASCII characters.

Default:

private

SNMP Security Subnet Mask Purpose:

The subnet mask that corresponds to the SNMP Security IP address. The 502X uses the security IP address and the security subnet mask to determine if the SNMP request was from a valid IP address. You can set multiple pairs of valid security IP addresses and subnet mask addresses so that the 502X will accept SNMP requests from multiple sources. For help with the IP address, see “SNMP Security IP Address” earlier in this chapter. For example, if you set a security IP address of 10.20.0.0 and a security subnet mask of 255.255.0.0, the 502X would authorize all SNMP requests with a source IP address of 10.20.n.n.

7-90