The text of a manual · part 6 of 33
502X Data Collection PC System Manual: Chapter 3: Customizing the 502X Using the Control Panel, pages 39 to 47
Pages 39 to 47 of 310, from 502X Data Collection PC System Manual
The original document is the PDF (2.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 5020
Page 39
3 Customizing the 502X Using the Control Panel
Page 40
dafadfafdafafda
Page 41
Customizing the 502X Using the Control Panel
3
This chapter describes how you can use the Control Panel applets to customize the look and operation of your 502X.
Using the Control Panel You can set many properties of the 502X to suit the needs of your environment. Use the Control Panel to customize properties on your 502X that you cannot change with the Configuration application, Unit Manager, SNMP commands, or bar code labels. Use this chapter to learn how to • set communications properties.
• set the date and time.
• create dialing properties.
• view or modify the desktop display properties.
• adjust the backlight shutoff period.
• adjust the keyboard properties.
• set owner information.
• set a password.
• view battery status and change power suspend time.
• enter regional settings.
• remove application programs.
• view system information.
• adjust memory allocation.
• adjust volume and sounds.
For help on navigating through the screens, see “Using the Keypad” in Chapter 1 of your user’s manual. Note: After a cold boot, all Control Panel settings are reset to the factory default values.
3-3
Page 42
502X Data Collection PC System Manual
To open the control panel 1. Open the Start menu and choose Programs.
&
2. Select Settings and then press . The Control Panel appears.
Setting Communications Properties You can use the Communications applet to • configure a device name on the 502X.
• select a serial or IrDA connection between a 502X and another computer.
Your network setup may require that each device has its own unique name. Check with your network administrator for this information. Follow the next instructions to configure the device name. For help configuring network parameters, see Chapter 2 in your user’s manual.
To configure the device name 1. In the Control Panel, use the arrow keys to highlight the Communications icon.
&
2. Press . The Communications Properties dialog box appears and the Device name field is highlighted.
3. Type a Device name (without any spaces) that is up to 15 characters long.
3-4
Page 43
Customizing the 502X Using the Control Panel
4. Press
3
3 to select the Device description field.
5. Type a short description for the device that is up to 50 characters long. The description is an optional field. 6. Press
& to close the dialog box and temporarily save your changes.
7. To save the device name permanently so that it will be restored after a cold boot, use the Configuration application to change a network parameter. Open the Start menu and choose Programs. 8. Choose Configuration and open the Configure menu.
&
9. Select Network and then press . The Network configuration screen appears.
3
10. Use the and arrow keys to navigate in the configuration screen. Change one network parameter. For example, change the TFTP timeout and increase the value by one.
3 to select the Apply button and then press &. 12. Press " " to open the File menu. Choose Exit, and press & to close the 11. Press
Configuration application.
'
13. Press twice to make the changes effective. The device name is now saved in permanent memory and will be restored after a cold boot. To establish an ActiveSync partnership between a 502X and another computer, you must first connect the 502X to the other computer using a D5020 Communications Dock or an L5020 Serial Communications Adapter. You can also use a serial I/O PC card in the batch 5020. For help, see “Connecting With a Serial I/O Card” in Chapter 3 of the 5020 user’s manual. For a serial connection, you install a serial I/O PC card in the batch 5020 and use the Remnet program to create and configure a custom serial connection. For an IrDA connection, you can use the D5020 or L5020 with any 502X. By default, the 502X uses an IrDA port connection. You use the PC Connection tab in the Communications applet to select a serial connection or to switch back to an IrDA port connection.
3-5
Page 44
502X Data Collection PC System Manual
To select a PC connection 1. In the Control Panel, use the arrow keys to highlight the Communications icon.
& 3. Press 3 to select the PC Connection tab and press &.
2. Press . The Communications Properties dialog box appears.
4. Press
3 to select the Change button and press &.
5. Press the arrow keys to select a serial connection (IrDA port or a serial connection such as “My Connection”).
& 7. Press 3 to move the focus from the Change button to the PC Connection tab. 8. Press & to close the dialog box. 6. Press . The Communications Properties dialog box appears.
3-6
Page 45
Customizing the 502X Using the Control Panel
3
Setting the Date and Time Caution If the 502X is turned off while the Date/Time Properties dialog box is open, the clock may not be accurate. Turn the 502X on and correct the time before closing the dialog box. Conseil Si l'appareil 502X est mis hors tension alors que la boîte de dialogue de Date and Time est ouverte, l'horloge risque d'être inexacte. Mettez le 502X sous tension et réglez l'horloge avant de fermer la boîte de dialogue. Use the Date/Time applet to set the time and date on the 502X system clock.
To set the date and time 1. In the Control Panel, use the arrow keys to highlight the Date/Time icon.
&
2. Press . The Date/Time Properties dialog box appears.
3. Press the arrow keys to select your time zone from the list box.
3 to select the calendar. Use the arrow keys to select the month, date, and year. 5. Press 3 to select the time box. • Press or ! to change a value. • Press 9 or 7 to move between hour, minutes, and seconds. 4. Press
You can also enter hour, minutes, and seconds directly if the field is selected.
3
6. If you do not want the time to display in your Notification Tray, press to select the Hide Clock check box and then press . You can also select the Hide Clock check box and create more space for application icons on the Notification Tray.
4
7. Press
& to close the dialog box and save your changes.
Note: After a cold boot, the date is reset to June 1, 2001 (January 1, 1999 on 5023), and the time is reset to 12:00 A.M.
3-7
Page 46
502X Data Collection PC System Manual
Creating Dialing Properties (Batch 5020 Only) You can use the Dialing applet to configure the batch 5020 so that you can connect it to other computers via a modem. You also need to use a modem PC card in the batch 5020. For help with PC cards, see “Using PC and Compact Flash Memory Cards” in Chapter 1 of the 5020 user’s manual.
To create a new location 1. In the Control Panel, use the arrow keys to highlight the Dialing icon.
&
2. Press . The Dialing Properties dialog box appears.
3
&
3. Press to highlight the Dialing Patterns button and press . You can now enter various dialing patterns.
4. Press
3-8
& to close the dialog box and save your changes.
Page 47
3
Customizing the 502X Using the Control Panel
Viewing or Modifying the Desktop Display You can use the Display Properties applet to select an image to display on the 502X desktop and to adjust the automatic backlight shutoff feature.
To view or modify display properties 1. In the Control Panel, use the arrow keys to highlight the Display icon.
&
2. Press . The Display Properties dialog box appears.
3
3. Use the arrow keys to select a background image from the list, or press to highlight the Browse button and press to locate the image you want to use. Windows CE uses bitmap (BMP) files for the desktop image.
&
4. Press
& to close the dialog box and save your changes.
Adjusting the Backlight Shutoff You can adjust the automatic backlight shutoff time to save battery life. The default backlight shutoff time is 15 seconds.
To view or modify the backlight shutoff time 1. In the Control Panel, use the arrow keys to highlight the Display icon.
& 3. Press 9 to select the Backlight tab.
2. Press . The Display Properties dialog box appears.
3-9