For the Intermec 5020

Page 27

2 Configuring and Connecting the 502X

Page 28

white

Page 29

Configuring and Connecting the 502X

2

This chapter includes a basic overview of direct and remote configuration methods. It also includes information about connecting the 502X to your wired or wireless network.

How to Configure the 502X You can configure many operating characteristics of the 502X Data Collection PC, such as the bar code symbologies it decodes or the network settings. These characteristics are controlled by configuration parameters. The values that you set for the configuration parameters determine how the computer operates. There are several ways to configure the 502X. The next section is an overview of configuration methods.

Setting Parameters Directly You can directly configure the 502X using these applications or methods: Fast Config When first setting up the 502X, use Fast Config to set or enable most basic network parameters and get the 502X connected to your network. For help, see “Using Fast Config” in Chapter 2 of your user’s manual. Configuration application Use the Configuration application to individually select and set all parameters and view system information. For help, see “Using the Configuration Application” in Chapter 2 of your user’s manual. Scan Bar Codes You can scan bar code labels to configure basic scanning parameters including symbology enabling and scanner operation. For help, see “Configuring the 502X by Scanning Bar Code Labels” in Chapter 2 of your user’s manual. Control Panel Applets You can change local unit settings such as memory allocation or dialing properties using the Control Panel applets. Some local unit settings can only be accessed through the Control Panel. For help, see Chapter 3, “Customizing the 502X Using the Control Panel.”

Setting Parameters Remotely After the 502X is communicating in your network, you can use these methods to remotely configure all parameters: Configuration Management Use a Web browser on your desktop PC and the Configuration Management application in Unit Manager to individually select and set all parameters and view system information. You can configure parameters for each 502X on your network one at a time using Configuration Management. For help, see “Using Configuration Management” in Chapter 4. SNMP Commands You can configure all parameters by sending SNMP commands to the 502X from an SNMP management station. For help, see “Configuring the 502X by Using SNMP” later in this chapter.

2-3

Page 30

502X Data Collection PC System Manual

Using Fast Config The Fast Config application is designed to help you quickly enter basic network parameters and get the 502X connected to your wired or RF network. Fast Config presents a series of dialog boxes that allows you to set basic network parameters including • date and time.

• baud rate of a host PC serial port.

•

DHCP server enabling.

•

IP address, subnet mask, and default router.

• primary and secondary WINS addresses.

• primary and secondary DNS addresses.

• security ID and domain for OpenAir radios.

• network name and WEP key for 802.11b HR radios.

• device name.

To set other parameters, use the Configuration application. After you use Fast Config, the 502X should be communicating with your wired or RF network. When an RF 502X is in range of the access point, the icon appears and remains on in the Notification Tray indicating that the 502X is communicating with the access point. To access Fast Config

1. Open the Start menu and select Programs. 2. Select Fast Config and press Enter. The Welcome screen appears.

Follow the onscreen prompts to set or enable network parameters. For help, see “Using Fast Config” in Chapter 2 of your user’s manual.

2-4

Page 31

Configuring and Connecting the 502X

2

Using the Configuration Application You can use the Configuration application to • view, change, or set all parameters in real time.

• view system and terminal information.

• restore factory defaults to a selected group of parameters or all parameters as needed. Note: Because using the Restore Factory Defaults option resets all network parameters, a loss of network communications may result. This option should only be used by your network administrator or by Intermec support personnel. After using this option, a warm boot may be necessary to restart the 502X.

You can access the Configuration application while running any application. You can also extend and customize the Configuration application. For help, see Appendix D, “Extending the Configuration Applications.” To access the Configuration application

1. Open the Start menu and select Programs. 2. Select Configuration and press Enter. The Configuration main screen appears.

For more information, see “Using the Configuration Application” in Chapter 2 of your user’s manual.

2-5

Page 32

502X Data Collection PC System Manual

Scanning Bar Code Labels to Set Parameters You can configure the 502X by scanning bar code labels listed in this manual or by creating your own Code 39 or Code 93 bar code labels. For configuration bar codes, see Chapter 7, “Configuration Command Reference.” You can enable and set the following parameters by scanning bar codes: •

Automatic Shutoff

•

Interleaved 2 of 5

•

Beep Duration (5020 only)

•

Keypad Caps Lock

•

Beep Frequency (5020 only)

•

Keypad Clicker

•

Beep (Speaker) Volume

•

MSI

•

Codabar

•

PDF 417

•

Code 11 (5020 only)

•

Plessey (5020 only)

•

Code 16K (5020 only)

•

Postamble

•

Code 2 of 5

•

Preamble

•

Code 39

•

Scanner Mode (5020 only)

•

Code 49 (5020 only)

•

Scanner Redundancy

•

Code 93/93i

•

Scanner Selection (5020 only)

•

Code 128

•

Scanner Timeout

•

Decode Priority (5020 only)

•

Scanner Trigger

•

Decode Security

•

Symbology Identifier (5020 only)

•

Display Backlight Timeout

•

UPC/EAN

You need to configure all other commands using the Configuration application, the Configuration Management application in Unit Manager, or SNMP. For help, see “Configuring the 502X by Scanning Bar Codes” in Chapter 2 of your user’s manual.

2-6

Page 33

Configuring and Connecting the 502X

2

Configuring the 502X by Using SNMP The 502X is an SNMP-enabled device. You can use an SNMP management station to control and configure the 502X anywhere on an SNMP-enabled network. The 502X supports proprietary Management Information Bases (MIBs). You will find the MIB files for the 502X on the Intermec Web site at www.intermec.com. MIB File

Description intermec.mib

Defines the root of the Intermec MIB tree.

itcadc.mib

Defines objects for Automated Data Collection. For example, bar code symbologies.

itcfile.mib

Defines objects for manipulating and viewing files. For example, TFTP Timeout.

itcnetwork.mib

Defines objects for Network parameters. For example, 502X IP address.

itcsnmp.mib

Defines objects for Intermec SNMP parameters and security methods. For example, SNMP security IP address.

itcterminal.mib

Defines objects for terminal parameters. For example, keypad clicker.

In addition to the MIB files, Intermec provides SNMP support for MIB II through seven read-only MIB II (RFC1213-MIB) OIDs. You can only query these seven OIDs through an SNMP management station. The OIDs are not available in the Configuration application or the Unit Manager applications. MIB II Item

OID

Group or Table

Description ifNumber

1.3.6.1.2.1.2.1.0

Interfaces group

Indicates the number of adapters present in the system. For the 502X, if one adapter is present in the system, then ifNumber = 1 and ifIndex = 1.

ifIndex

1.3.6.1.2.1.2.2.1.1.ifIndex

Interfaces table (ifTable)

A unique value for each interface. The value ranges between 1 and the value of ifNumber.

ifDescr

1.3.6.1.2.1.2.2.1.2.ifIndex

Interfaces table (ifTable)

A textual string containing information about the interface.

2-7

Page 34

502X Data Collection PC System Manual

Read-Only MIB II OIDs (continued)

MIB II Item

OID

Group or Table

Description ifType

1.3.6.1.2.1.2.2.1.3.ifIndex

Interfaces table (ifTable)

An integer containing information about the type of the interface. It is equal to 1 for Other.

ipAdEntAddr

1.3.6.1.2.1.4.20.1.1.IpAddress

IP address table (ipAddrTable)

The IP address to which this entry’s addressing information pertains (same as 502X IP address). Where IpAddress is the user’s entered valid non-zero IP address of the 502X, for example, 10.20.10.152.

ipAdEntIfIndex

1.3.6.1.2.1.4.20.1.2.IpAddress

IP address table (ipAddrTable)

The index value that uniquely identifies the interface to which this entry is applicable (same as ifIndex).

ipAdEntNetMask

1.3.6.1.2.1.4.20.1.3.IpAddress

IP address table (ipAddrTable)

The subnet mask associated with the IP address of this entry (same as Subnet Mask).

The community string allows an SNMP manager to manage the 502X with a specified privilege level. The default read-only community string is “public.” The default read/write community string is “private.” To configure the 502X using SNMP

1. Use the Configuration application or the Configuration Management application in Unit Manager to configure your 502Xs for RF or Ethernet communications. 2. Determine the OID (Object Identifier) for the parameter that you want to change. The Intermec base OID is: 1.3.6.1.4.1.1963 3. Use your SNMP management station to get and set variables that are defined in the Intermec MIBs. You can set the traps, identification, or security configuration parameters for SNMP. For help, see Chapter 7, “Configuration Command Reference.”

2-8

Page 35

Configuring and Connecting the 502X

2

Connecting the 502X To Your Network You can easily use the 502X as an end device in your wired or RF network. There are several ways to connect the 502X to your network: •

Install an Ethernet card or a serial I/O card (purchased separately) in a batch 5020 to communicate with other devices in your network.

•

Use the radio in an RF 502X to communicate with other RF devices in your network.

•

Use the IrDA port to transfer data between the 502X and a host computer.

Learning About Network Protocols The 502X communicates using either of these network protocol options: •

TCP/IP

•

UDP Plus

The 502X ships with TCP/IP enabled. In a TCP/IP network, the 502X communicates directly through the access points or through the Ethernet network to the host or server. UDP Plus is an Intermec protocol built on top of the User Datagram Protocol (UDP). It maximizes the performance of RF networks and provides robust data communications. In a UDP Plus network, the 502X communicates through the DCS 30X to the host or server. If you have a DCS 30X network, you must enable UDP Plus on the 502X. TCP/IP

502X

Host

UDP Plus

502X

502X

502X

Access point

Access point

Ethernet DCS 30X

502X

502X

502X

502X

502SX004.eps

2-9

Page 36

502X Data Collection PC System Manual

The network parameters you need to set depend on your network environment. If you are using a DHCP (Dynamic Host Configuration Protocol) server, the 502X broadcasts a message to the server, and the DHCP server assigns these network parameters: •

IP address

•

Subnet mask

•

Default router

•

Primary and secondary DNS servers

•

Primary and secondary WINS servers

DHCP is automatically enabled on the 502X. If you are not using a DHCP server, you need to disable DHCP and manually set the network parameters. You only need to set the DNS and WINS servers if they are required for your network communications. If you are on a network that uses a WINS server or you want to use universal naming conventions (UNC) such as \\computer_name\share_name\filename, you need to set the device name. For help with setting the device name, see “Setting Communications Properties” in Chapter 3.

Learning About RF Network Settings (RF 502Xs only) Caution Make sure all components with antennas are at least 30 centimeters (1 foot) apart when power is applied. Failure to comply could result in equipment damage. Conseil Assurez-vous que la distance entre tous les éléments avec antennes soit d’au moins 30 centimètres (un pied) avant de faire la connexion avec l’alimentation électrique, faute de quoi vous risquez d’endommager votre installation. Your RF 502X ships with either an OpenAir radio or an 802.11b HR radio. To connect to an RF network, you need to

2-10

• configure your access point(s).

• configure the 502X radio parameters. For an OpenAir radio, you need to set the security ID and domain. For an 802.11b HR radio, you need to set the network name and WEP key.

Page 37

Configuring and Connecting the 502X

2

The access point acts as a bridge to provide RF communications between the 502X and the DCS 30X or host. When you first consider purchasing an RF data collection system, an Intermec representative works with you to perform a site survey at your facility. The survey analyzes the range of RF devices in your facility, determines the placement of the access points, and ensures that the access point coverage overlaps to provide uninterrupted RF access at any location within the building. This manual assumes that a site survey is complete and the access points are installed. If the host computer communicates with the 502X through 011X access points, you may need to add the 502X IP address and MAC address as a static entry in the host’s ARP table.

Setting the Network Parameters You can use the Fast Config application to quickly set the parameters for a TCP/IP network. For help with Fast Config, see “Using Fast Config” in Chapter 2 of your user’s manual. For a UDP Plus network, follow the Fast Config instructions and then use the Configuration application to enter UDP parameters and enable the network. For help with enabling UDP Plus, see Chapter 3 of your user’s manual. You can also configure each network and radio parameter using the Configuration application. For help, see “Using the Configuration Application” in Chapter 2 of your user’s manual. After you have connected the 502X to your network, you can remotely change all network parameters by using the Configuration Management application in Unit Manager from your desktop PC. For help, see “Using Configuration Management” in Chapter 4. You can also remotely change all network parameters on the 502X by sending SNMP commands from an SNMP management station. For help, see “Configuring the 502X by Using SNMP” earlier in this chapter.

Configuring for Serial or IrDA Communications The 502X has an IrDA port to transmit data to and from a host computer via IrDA communications. To convert the IrDA port to an RS-232 serial port, you need an L5020 Serial Communications Adapter, a D5020 Communications Dock, or (for batch 5020s only) a serial input/output (I/O) PC card.

2-11

Page 38

502X Data Collection PC System Manual

502X Data Collection PC in a Wired Network

Host

File server

502X with L5020 Serial Communications Adapter Terminals Ethernet

PC

502XS010.eps

502X in a D5020 Communications Dock

5020 with serial I/O PC card installed

For help connecting the 502X to another device, see your user’s manual.