Page 75
Using Unit Manager
4
Changing File Attributes 1. Connect to the 502X using a Web browser and start Unit Manager. For help, see “To connect to the 502X from your desktop PC” earlier in this chapter. 2. Click File Manager. The main File Manager screen appears. 3. To navigate to the directory with the file you want to change, click the option button next to the directory, and then click the GoTo button. To change the attributes of a file in the current directory, continue with Step 4. 4. Click the option button next to the file you want to change. 5. Click the Attributes button. The Set File Attributes screen appears. Mark or clear the appropriate check box in the New Attributes box. You can only change the Read-only, Hidden, and Archive attributes.
6. Click the Set File Attributes button to change the file attribute, click Cancel to end the request, or click Reset to erase all changes on the form. The screen showing the parent directory is refreshed. If the change attribute operation was successful, the new file attributes are displayed in the Directory listing along with a confirming message: Successfully set the file attributes of Filename where Filename is the modified file.
4-19
Page 76
502X Data Collection PC System Manual
Using File Manager to Run an Executable on the 502X You can use File Manager to run an executable (EXE) file on the 502X. To run an executable file
1. Connect to the 502X using a Web browser and start Unit Manager. For help, see “To connect to the 502X from your desktop PC” earlier in this chapter. 2. Click File Manager. The main File Manager screen appears. 3. To navigate to the directory with the file you want to run, click the option button next to the directory, and then click the GoTo button. To run a file in the current directory, continue with Step 4. 4. Click the option button next to the file you want to run. 5. Click the Run button. The Run Executable screen appears. Enter any command line parameters on the form.
6. Click the Run Executable button to run the executable. The screen showing the parent directory appears with a confirming message: Successfully executed the file Filename where Filename is the executable.
4-20
Page 77
Using Unit Manager
4
Using Process Manager The Process Manager is very similar to the Windows Task Manager. You can use Process Manager to • display processes running on the 502X.
• close processes running on the 502X. A close command ends a process and gives the process time to “clean up” before it stops functioning.
• kill processes running on the 502X. A kill command ends a process but does not let the process “clean up” before it stops functioning.
• view a list of the default local heap for a selected process. The list can be a useful debugging tool for finding application memory leaks.
• view all threads associated with specific processes.
• view all modules associated with specific processes.
To run Process Manager
1. Connect to the 502X using a Web browser and start Unit Manager. For help, see “To connect to the 502X from your desktop PC” earlier in this chapter. 2. Click Process Manager. The main Process Manager screen appears.
3. Choose the function you want to perform. Each function is explained in the sections that follow.
4-21
Page 78
502X Data Collection PC System Manual
Managing Processes Running on the 502X When you click Get Processes, a screen appears showing the processes that are part of a larger process or program on the 502X. To close a process
1. Connect to the 502X using a Web browser and start Unit Manager. For help, see “To connect to the 502X from your desktop PC” earlier in this chapter. 2. Click Process Manager. The main Process Manager screen appears. 3. Click the Get Processes button. The Process List screen appears.
4. Click the option button to select the process you want to close. 5. Click the Request to Close button. An informative message appears, indicating that the request to close command was successful.
An error message may appear if you try to close a process that does not have a window. Processes without windows do not have handles and will not accept a close command. 6. Click the Refresh Process List button to get an updated list of processes running on the 502X.
4-22
Page 79
Using Unit Manager
4
To kill a process
1. Connect to the 502X using a Web browser and start Unit Manager. For help, see “To connect to the 502X from your desktop PC” earlier in this chapter. 2. Click Process Manager. The main Process Manager screen appears. 3. Click the Get Processes button. The Process List screen appears. 4. Click the option button to select the process you want to kill. 5. Click the Kill Process button. An informative message appears, indicating that the kill command was successful.
An error message may appear if you try to kill a process that does not have a window. Processes without windows do not have handles and will not accept a kill command. 6. Click the Refresh Process List button to get an updated list of processes running on the 502X. To view the default local heap for a selected process
1. Connect to the 502X using a Web browser and start Unit Manager. For help, see “To connect to the 502X from your desktop PC” earlier in this chapter. 2. Click Process Manager. The main Process Manager screen appears. 3. Click the Get Processes button. The Process List screen appears. 4. Click the option button to select the process you want to view.
4-23
Page 80
502X Data Collection PC System Manual
5. Click the Walk Heap button. The default local heap list appears, with an entry for each heap block showing its starting address, size, and status.
6. To refresh this page, click the Refresh Process List button. After the page is refreshed, click the Walk Heap button. Repeatedly refreshing this page can often give insight into which blocks are leaking. To view the default local heap sorted by size
1. Connect to the 502X using a Web browser and start Unit Manager. For help, see “To connect to the 502X from your desktop PC” earlier in this chapter. 2. Click Process Manager. The main Process Manager screen appears. 3. Click the Get Processes button. The Process List screen appears. 4. Click the option button to select the process you want to view. 5. Click the Heap Stats button. The default local heap list appears, sorted by size of heap blocks.
6. To refresh this page, click the Refresh Process List button. After the page is refreshed, click the Heap Stats button. Repeatedly refreshing this page can often give insight into which blocks are leaking.
4-24
Page 81
Using Unit Manager
4
Displaying Threads Running on the 502X You can use Process Manager to view all threads associated with specific processes. To view all threads
1. Connect to the 502X using a Web browser and start Unit Manager. For help, see “To connect to the 502X from your desktop PC” earlier in this chapter. 2. Click Process Manager. The main Process Manager screen appears. 3. Click the Get Threads button. The Thread List appears.
4-25
Page 82
502X Data Collection PC System Manual
Displaying Modules Running on the 502X You can use Process Manager to view all modules associated with specific processes. To view all modules
1. Connect to the 502X using a Web browser and start Unit Manager. For help, see “To connect to the 502X from your desktop PC” earlier in this chapter. 2. Click Process Manager. The main Process Manager screen appears. 3. Click the Get Modules button. The Module List appears.
4-26
Page 83
Using Unit Manager
4
Using Application Manager You can use Application Manager to install or uninstall applications on your 502X. •
The Application Manager can only be used to install cabinet (CAB) files created using CABARC. CABARC is the CAB file creation software included with the 502X Software Developer’s Kit, available on the Windows CE/Pocket PC Developer's Kit CD-ROM (Part No. 069511). CAB files contain EXE files, data files, and registry settings for an application.
•
You can also uninstall an application by removing the device information file (INF) from the 502X.
Note: You cannot use Application Manager to install an EXE file that will in turn install an application on the 502X. To run Application Manager
1. Connect to the 502X using a Web browser and start Unit Manager. For help, see “To connect to the 502X from your desktop PC” earlier in this chapter. 2. Click Application Manager. The Application Manager screen appears.
4-27