For the Intermec 5020

Page 84

502X Data Collection PC System Manual

Installing an Application 1. Connect to the 502X using a Web browser and start Unit Manager. For help, see “To connect to the 502X from your desktop PC” earlier in this chapter. 2. Click Application Manager. The Application Installer screen appears. 3. Click the Browse button to locate the CAB file you want to install. The Choose File dialog box appears.

4. Click the CAB file you want to install on the 502X. The CAB file name appears in the File Name field. Click Open. 5. Click the Install button. You will see informative messages as the installation progresses.

4-28

Page 85

Using Unit Manager

4

Application Manager also provides informative messages if there are problems installing an application on the 502X. Message

Explanation

The file [Filename.ext] is not a valid CAB file.

You can only install .CAB files on the 502X. This message appears when you try to install another type of file, usually an .EXE or .DLL, on the 502X.

The CAB File [Filename] is for another CPU type!

This message appears if you selected a .CAB file that is for another CPU type.

There isn’t enough free disk space on the CE device.

You need to remove files from the 502X to create additional disk space for the application.

Current free disk space on the CE device = _____ Size of CAB file [Filename] = _____

Uninstalling an Application 1. Connect to the 502X using a Web browser and start Unit Manager. For help, see “To connect to the 502X from your desktop PC” earlier in this chapter. 2. Click Application Manager. The main Application Manager screen appears. 3. In the INF File field, enter the full path and filename of the INF file that you want to uninstall. If you don’t know the location of the INF file, use File Manager to determine the path of the INF file that you want to remove.

4. Click the Uninstall button to uninstall the application. 5. If the uninstall was successful, you will see the following message: Successfully uninstalled the application ApplicationName where ApplicationName is the name of the application that was uninstalled.

4-29

Page 86

502X Data Collection PC System Manual

Using the Event Viewer You can use the Event Viewer when you are troubleshooting problems on the 502X. You can copy the transactions on the Event Viewer screen and e-mail them to Intermec Product Support (support@intermec.com) to aid in problem resolution. Product Support can access the Event Viewer directly if the 502X is accessible through the Internet. To run the Event Viewer application

1. Connect to the 502X using a Web browser and start Unit Manager. For help, see “To connect to the 502X from your desktop PC” earlier in this chapter. 2. Click Event Viewer. The Event Viewer screen appears.

Viewing the Event Logging Buffer The Event Logger provides the capability to save Intermec-system-software generated events for later review. The events are saved in an Event Logging Buffer that defaults to a capacity of 1000 event records before the older message records are overwritten (firstin/first-out). Each record includes a timestamp indicating when the event occurred, a facility name indicating the software area that generated the event, the assigned severity category (informational, success, warning, or error), an Event Code number, and a description of the event. Records collected in the Event Logging Buffer may be retreived and viewed using the Event Viewer.

4-30

Page 87

Using Unit Manager

4

To view the Event Logging Buffer

1. Connect to the 502X using a Web browser and start Unit Manager. For help, see “To connect to the 502X from your desktop PC” earlier in this chapter. 2. Click Event Viewer. The Event Viewer screen appears. 3. Click the Get Formatted Events button. The screen is refreshed with the current contents of the Event Logging Buffer.

Setting an Event Filter You can set the Global Filter or the Facility Filter. The Global Filter determines the events that can be captured on a system-wide basis. The Facility Filter determines the events that can be captured on a software-component basis and is used to filter out specific events that are allowed by the Global Filter. To set the event filter

1. Connect to the 502X using a Web browser and start Unit Manager. For help, see “To connect to the 502X from your desktop PC” earlier in this chapter. 2. Click Event Viewer. The Event Viewer screen appears.

4-31

Page 88

502X Data Collection PC System Manual

3. Click the Set Filter button. The Global and Facility Filters screen appears. You can choose to globally capture all error, warning, or success events, or you can choose to capture only events specific to a given facility.

4. Do one of the following: •

In the Global Filter box, click Error, Warning, or Success to choose the type of event you want to capture, and then click Apply Global Filter.

•

In the Facility Filter box, click on the facility you want to filter, and then click Error, Warning, Success, or Informational to choose which kinds of events you want to capture. Click Add Facility to enable the filter.

5. Click Return to Event Log. The Event Viewer screen appears, showing only the events you selected to capture.

Tracing Events You can set the Event Logger to suspend logging after a specified Event Value occurs. This prevents the normal discarding of older event information when the Event Logging Buffer is full. To set a trace

1. Connect to the 502X using a Web browser and start Unit Manager. For help, see “To connect to the 502X from your desktop PC” earlier in this chapter. 2. Click Event Viewer. The Event Viewer screen appears.

4-32

Page 89

Using Unit Manager

4

3. Click Set Trace. The Trace Criteria screen appears.

4. Enter the Event Value in the Trace Event Value in Hex field. The Event Value is the same as the Event Code as seen in the Event Logging Buffer. You can also enter an Event Value of 0 to set the trace point for any success message, 1 for any informational message, 2 for any warning message, or 3 for any error message. 5. Click one of the option buttons to select a logging suspension parameter: •

Choose Pre to stop logging immediately after the trace event occurs.

•

Choose Center to stop logging after the trace event occurs and when the logging buffer is half full.

•

Choose Post to start logging when the trace event occurs and stop logging when the buffer is full.

6. Click Enable Trace to accept the parameters. The Event Value and suspension parameter appear in the Status box.

4-33

Page 90

502X Data Collection PC System Manual

Clearing Events •

Click the Clear Events button to clear the Event Viewer screen.

Managing Your Passwords You can use the Password application to set or clear a password on a remote 502X. When a password has been set for a 502X,

4-34

• you must enter the password to access Unit Manager.

• the 502X is placed in User mode, which limits access to the Configuration application and the Control Panels. You cannot make changes to the 502X’s parameters unless you place the 502X in Admin mode and enter the password when prompted.

Page 91

Using Unit Manager

4

To set, change, or clear a password

1. Connect to the 502X using a Web browser and start Unit Manager. For help, see “To connect to the 502X from your desktop PC” earlier in this chapter. 2. Click Password. The Password screen appears.

3. Do one of the following: •

To set a password, enter it in the Password field, and enter it again in the Confirm Password field. Click the Enable Security check box.

•

To change a password, enter the current password in the Old Password field. Enter the new password in the Password field, and enter the new password again in the Confirm Password field. Click the Enable Security checkbox.

•

To clear a password, enter it in the Old Password field. Leave the Password and Confirm Password fields blank.

Note: Passwords may be up to 40 characters in length. Use non-alphanumeric characters only. 4. Click Submit. A success message confirms that the password was set, changed, or cleared.

4-35

Page 92

502X Data Collection PC System Manual

5. Do one of the following to place the 502X in User mode: •

Warm boot the 502X. For help, see “Booting the 502X” in Chapter 4 of your user’s manual. When the warm boot is completed, the 502X is placed in User mode.

•

Open the Start menu. Select Goto User Mode and press Enter. The 502X is placed in User mode.

Placing the 502X in User mode enables the password settings. You cannot access the Configuration application or the Control Panels when the 502X is in User mode. To place the 502X in Admin mode

1. Open the Start menu. Select Goto Admin Mode and press Enter. The Enter Password dialog box appears. 2. Enter the password and press Enter. The 502X is placed in Admin mode, and you can access the Configuration application and the Control Panels.

4-36