Page 179

Configuration Command Reference

7

IE Home Page Purpose: Configuration:

Sets the URL for the IE browser home page. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

No

No

No

In the Configuration or Configuration Management application, choose Configure and then IE Browser. Choose Options and then choose Home Page. You can also set the home page URL in the IE browser. Choose View and then choose Internet Options. On Cold Boot:

Not saved

Options:

Variable

Default:

files://\windows\ie502X.jpg

IE Proxy Server Address Purpose: Configuration:

Sets the address of the proxy server IE uses to make Internet connections. This setting is inactive unless the Use Proxy Server command is enabled. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

No

No

No

In the Configuration or Configuration Management application, choose Configure and then IE Browser. Choose Options and then choose Proxy Server. You can also set the Proxy Server Address in the IE Browser. Choose View and then choose Internet Options. On Cold Boot:

Not saved

Options:

Variable

Default:

null

7-51

Page 180

502X Data Collection PC System Manual

IE Proxy Server Port Purpose:

Configuration:

Sets the port used on the proxy server (enabled through the IE Browser) that is connected to the 502X. This setting is inactive unless the Use Proxy Server command is enabled. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

No

No

No

In the Configuration or Configuration Management application, choose Configure and then IE Browser. Choose Options and then choose Use LAN (No Auto Dial). You can also set the Proxy Server Port in the IE browser. Choose View and then choose Internet Options. On Cold Boot:

Not saved

Options:

Variable

Default:

null

IE Underline Links Purpose:

Configuration:

Determines if links displayed in the IE browser are underlined, not underlined, or have a focus placed on them. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

No

No

No

In the Configuration or Configuration Management application, choose Configure and then IE Browser. Choose Options and then choose Underline Links. You can also set this command in the IE browser. Choose View and then choose Internet Options.

7-52

Page 181

Configuration Command Reference

7

IE Underline Links (continued)

On Cold Boot:

Not saved

Options:

0 1 2

Always Never Hover

Default:

Always

IE Use LAN (No Auto Dial) Purpose:

Configuration:

Determines if the IE browser will use a LAN for Internet connections. When this command is enabled, IE will not autodial. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

No

No

No

In the Configuration or Configuration Management application, choose Configure and then IE Browser. Choose Options and then choose Use LAN (No Auto Dial). You can also set this command in the IE browser. Choose View and then choose Internet Options. On Cold Boot: Options:

Not saved Acceptable values are: 0 1

Default:

Disable Enable

Enable

7-53

Page 182

502X Data Collection PC System Manual

IE Use Proxy Server Purpose: Configuration:

Determines whether the IE browser uses a proxy server. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

No

No

No

In the Configuration or Configuration Management application, choose Configure and then IE Browser. Choose Use Proxy Server. You can also enable this command in the IE Browser. Choose View and then choose Internet Options. On Cold Boot: Options:

Not saved Acceptable values are: 0 1

Default:

True False

False

Inactivity Timeout (5020 only) Purpose:

Defines the amount of time the OpenAir radio on the 5020 waits to go into a low power state. If no data is sent or received within the RF inactivity timeout period set, the radio goes into a low power state to conserve power. If you set a high value, the radio stays on longer at a higher power rate and uses battery power at a faster rate. After you change this parameter, suspend and resume the 5020 to make the change effective. Power Management Tip: Intermec strongly recommends that you use the optimum RF inactivity timeout of 5 seconds to preserve power.

Configuration:

Use one of these methods: Configuration

7-54

Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

No

No

Page 183

Configuration Command Reference

7

Inactivity Timeout (continued)

In the Configuration or Configuration Management application, choose Configure and then Network. Next, choose Radio, then Radio, and finally choose Inactivity Timeout. On Cold Boot: SNMP OID:

Saved 1.3.6.1.4.1.1963.5.5.2.5.1.1.8.index where index is the radio adapter card number.

Options:

Acceptable values for the inactivity timeout are: 0 1-60

Radio never turns off RF inactivity timeout in seconds

Although you can enter any value from 1-60, the inactivity timeout is rounded to the nearest multiple of five (i.e., 5, 10, 15, …, 60). Default:

5 seconds

Interleaved 2 of 5 Purpose:

Enables or disables decoding of Interleaved 2 of 5 (I 2 of 5), a high-density, selfchecking, continuous numeric symbology. It is mainly used in inventory distribution and the automobile industry. Note: For the 5020 only, enabling I 2 of 5 automatically disables Code 2 of 5.

Configuration:

Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

Yes

No

In the Configuration or Configuration Management application, choose Configure and then Data Collection. Next, choose Symbologies and then choose Interleaved 2 of 5. On Cold Boot: SNMP OID: Syntax:

Not saved 1.3.6.1.4.1.1963.15.3.3.1.1.2.1 CAdata

7-55

Page 184

502X Data Collection PC System Manual

Interleaved 2 of 5 (continued)

You only use the two-character command CA for bar code configuration labels. Acceptable values for data are: 0 2-32 97 98 99

Disabled Fixed length (even number only) Variable length without a check digit Case code (6 or 14) with a check digit Variable length with a check digit

Caution Using the variable length without a check digit configuration option can cause substitution errors. Conseil Des erreurs de substitution peuvent survenir si vous utilisez la longueur variable sans option de vérification de configuration de chiffres. Default: Scan:

Variable length with a check digit One of these bar codes: Disable Interleaved 2 of 5

Enable Variable Length Without a Check Digit

*$+CA0*

*$+CA97*

Enable Variable Length With a Check Digit

Enable Interleaved 2 of 5, Case Code

*$+CA0*

*$+CA99* *$+CA99*

Or:

To set Interleaved 2 of 5 to a fixed length: 1. Scan this bar code: Enter Accumulate Mode / Set Fixed Length

*+/$+CA* *+/$+CA*

7-56

*$+CA97*

*$+CA98*

*$+CA98*

Page 185

Configuration Command Reference

7

Interleaved 2 of 5 (continued)

2. Scan a numeric value for data from these bar codes. (Use even numbers 2-32 only)

*0*

*1*

*2*

*3*

*0*

*1*

*2*

*3*

*4*

*6*

*4*

*6*

*8* *8*

3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

IrDA Baud Rate Purpose:

Configuration:

Sets the baud rate for the IrDA communications port on the 502X. The baud rate must match the baud rate of the device (i.e., the host computer) that the 502X is communicating with through the IrDA port and the D5020 Communications Dock or the L5020 Serial Communications Adapter. You must connect the 502X to a D5020 dock or an L5020 adapter to set the IrDA baud rate. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

No

Yes

In the Configuration or Configuration Management application, choose Configure and then Unit. Next, choose Serial Port and then choose IrDA Baud Rate. On Cold Boot: SNMP OID:

Not saved 1.3.6.1.4.1.1963.10.7.3.2.1.2.0

7-57

Page 186

502X Data Collection PC System Manual

IrDA Baud Rate (continued)

Options:

Acceptable values for the baud rate are: 9600 19200 38400 57600 115200

Default:

115200

Keypad Caps Lock Purpose:

Configuration:

Turns the caps lock on and off. With the caps lock turned on, all alphabetic characters you type on the keypad will be uppercase or capital letters. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

Yes

No

In the Configuration or Configuration Management application, choose Configure and then Unit. Next, choose Keypad and then choose Caps Lock. On Cold Boot: SNMP OID: Syntax:

Not saved 1.3.6.1.4.1.1963.15.12.2.0 KAdata You only use the two-character command KA for bar code configuration labels. Acceptable values for data are: 0 1

Default: Scan:

Caps lock off Caps lock on

Caps lock on One of these bar codes: Caps Lock Off

Caps Lock On

*$+KA0*

*$+KA1*

*$+KA0*

7-58

*$+KA1*

Page 187

Configuration Command Reference

7

Keypad Clicker Purpose:

Configuration:

Enables or disables the keypad clicks. The 502X sounds a click each time you press a key or decode a row of a two-dimensional symbology. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

Yes

No

In the Configuration or Configuration Management application, choose Configure and then Unit. Next, choose Keypad and then choose Key Clicks. On Cold Boot: SNMP OID: Syntax:

Not saved 1.3.6.1.4.1.1963.15.12.1.0 KCdata You only use the two-character command KC for bar code configuration labels. Acceptable values for data are: 0 1 2

Default: Scan:

Disable keypad clicker Enable soft keyclicks Enable loud keyclicks

Enabled with loud keyclicks One of these bar codes: Disable Keypad Clicker

*$+KC0* *$+KC0*

Enable Soft Keyclicks

*$+KC1* *$+KC1*

Enable Loud Keyclicks

*$+KC2* *$+KC2*

7-59

Page 188

502X Data Collection PC System Manual

Maximum Retries Purpose:

Defines the number of times the 502X will attempt to send a disconnect request message to the DCS 30X. The 502X sends connect and disconnect request messages to the DCS 30X when you turn the 502X on and off. Tip: Intermec strongly recommends that you use the optimum setting of seven retries.

Configuration:

Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

No

No

In the Configuration or Configuration Management application, choose Configure and then Network. Next, choose Protocols, then UDP Plus, and finally choose Maximum Retries. On Cold Boot: SNMP OID: Options:

Not saved 1.3.6.1.4.1.1963.5.15.20.1.1.1.4.1 Acceptable values for the retries are: 0 1-99

Default:

502X retries indefinitely Number of retries

7

Maximum Sleep Duration Purpose:

Configuration:

Specifies the maximum time (in milliseconds) the 802.11b HR radio is allowed to sleep. If Power Management is disabled, this parameter is ignored. Use one of these methods: Configuration

7-60

Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

No

No