Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 22 of 33

502X Data Collection PC System Manual: Chapter 7: Configuration Command Reference, pages 189 to 198

Pages 189 to 198 of 310, from 502X Data Collection PC System Manual

The original document is the PDF (2.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 5020

Page 189

Configuration Command Reference

7

Maximum Sleep Duration (continued)

In the Configuration or Configuration Management application, choose Configure and then Network. Next, choose Radio, then Radio, then Power Management, and finally choose Maximum Sleep Duration. On Cold Boot: SNMP OID:

Saved 1.3.6.1.4.1.1963.5.5.2.4.1.1.6.ifindex where ifindex is the radio adapter card number.

Options:

From 1 to 6553 ms

Default:

100 ms

Purpose:

Enables or disables decoding of MSI symbology. MSI code is similar to Plessey code. MSI code includes a start pattern, data characters, one or two check digits, and a stop pattern.

MSI

Configuration:

Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

Yes

No

In the Configuration or Configuration Management application, choose Configure and then Data Collection. Next, choose Symbologies and then choose MSI. On Cold Boot: SNMP OID:

Not saved 1.3.6.1.4.1.1963.15.3.3.1.1.15.1

7-61

Page 190

502X Data Collection PC System Manual

MSI (continued)

Syntax:

CNdata You only use the two-character command CN for bar code configuration labels. Acceptable values for data are:

Default: Scan:

First digit:

0 1 2 3

Disabled (5020 only) No check digits 1 modulus 10 check digit 2 modulus 10 check digit

Second digit:

0 1

Discard check digit Transmit check digit

Disabled One of these bar codes: Disable MSI

MSI Without Check Digits (5020 only)

*$+CN00*

*$+CN10*

*$+CN00*

*$+CN10*

MSI With 1 Modulus 10 Check Digit, Discard Check Digit

*$+CN20* *$+CN20*

MSI With 1 Modulus 10 Check Digit, Transmit Check Digit

*$+CN21* *$+CN21*

MSI With 2 Modulus 10 Check Digits, Discard Check Digits

*$+CN30* *$+CN30*

MSI With 2 Modulus 10 Check Digits, Transmit Check Digits

*$+CN31*

*$+CN31*

7-62

Page 191

Configuration Command Reference

7

Network Loopback Purpose:

Transmits all messages received from the DCS 30X back to the DCS 30X. Messages received by the radio are not passed on to the 502X applications unless they are configuration commands. Messages continue to be looped back to the DCS 30X as long as this feature is enabled. Messages originating from the 502X are still transmitted to the DCS 30X. Use the Network Loopback parameter to troubleshoot RF or Ethernet communications problems.

Configuration:

Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

No

No

In the Configuration or Configuration Management application, choose Configure and then Network. Next, choose Protocols, then UDP Plus, and finally choose Network Loopback. On Cold Boot: SNMP OID: Options:

Not saved 1.3.6.1.4.1.1963.5.15.20.1.1.1.13.1 Acceptable values for the Network Loopback parameter are: 0 1

Default:

Disabled Enabled

Disabled

Network Name Purpose:

Configuration:

This parameter is an alphanumeric string that must match the network name of the access point(s) to which your 502X should associate. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

No

Yes

7-63

Page 192

502X Data Collection PC System Manual

Network Name (continued)

In the Configuration or Configuration Management application, choose Configure and then Network. Next, choose Radio, then Radio, and finally choose Network Name. On Cold Boot: SNMP OID:

Saved 1.2.840.10036.1.1.1.9.ifindex where ifindex is the radio adapter card number.

Options:

0 to 32 byte ASCII string ANY The value ANY enables your 502X to connect to any access point in your 802.11b HR network.

Default:

INTERMEC

Network Port Purpose:

Configuration:

Defines the network port that UDP Plus uses for communications in your RF or Ethernet network. The network port you set on the 502X must match the network port that is set on the DCS 30X. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

No

No

In the Configuration or Configuration Management application, choose Configure and then Network. Next, choose Protocols, then UDP Plus, and finally choose Network Port. On Cold Boot: SNMP OID:

7-64

Not saved 1.3.6.1.4.1.1963.5.15.20.1.1.1.12.1

Options:

The network port can be any number from 5001 to 65535.

Default:

5555

Page 193

Configuration Command Reference

7

PDF 417 Purpose:

Enables or disables decoding of PDF 417, a stacked two-dimensional symbology that provides the ability to scan across rows of code. Each row consists of start/stop characters, row identifiers, and symbol characters, which consist of four bars and four spaces each and contain the actual data. This symbology uses error correction symbol characters appended at the end to recover loss of data. Because the virtual wedge translates incoming data into keypad input, the size of the keypad buffer limits the effective length of the label to 128 characters. Longer labels may be truncated. For PDF 417 labels of more than 128 characters, you can develop an application that bypasses the keypad buffer. For help, see the 502X Software Developer’s Kit, available on the Intermec Windows CE/Pocket PC Developer’s Kit (Part No. 069511). Note: PDF 417 is supported on the 5023 and on the 5020 when you use an Intermec 1470 scanner through the tethered scanner port.

Configuration:

Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

Yes

No

In the Configuration or Configuration Management application, choose Configure and then choose Data Collection. Next, choose Symbologies and then choose PDF 417. On Cold Boot: SNMP OID: Syntax:

Not saved 1.3.6.1.4.1.1963.15.3.3.1.1.17.1 CQdata Acceptable values for data are: 0 1

Default:

Scan:

Disabled Enabled

Disabled on 5020 Enabled on 5023 One of these bar codes: Disable PDF 417

Enable PDF 417

*$+CQ0*

*$+CQ1*

*$+CQ0*

*$+CQ1*

7-65

Page 194

502X Data Collection PC System Manual

Plessey (5020 only) Purpose:

Configuration:

Enables or disables decoding of Plessey symbology. Plessey code is pulse-width modulated like most other bar codes. It includes a start character, data characters, an eight-bit cyclic check digit, and a termination bar. The code is continuous and not self-checking. You need to configure two parameters for Plessey code: Start Code and Check Digit. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

Yes

No

In the Configuration or Configuration Management application, choose Configure and then Data Collection. Next, choose Symbologies and then choose Plessey. On Cold Boot: SNMP OID: Syntax:

Not saved 1.3.6.1.4.1.1963.15.3.3.1.1.10.1 CIdata You only use the two-character command CI for bar code configuration labels. Acceptable values for data are: 00 30 31

Default: Scan:

Disabled Transmit check digit Discard check digit

Disabled To disable Plessey: Disable Plessey

*$+CI00* *$+CI00*

Or:

To set Plessey, scan one of these bar codes to transmit or discard the check digit: Transmit Check Digit

Discard Check Digit

*$+CI30*

*$+CI31*

*$+CI30*

7-66

*$+CI31*

Page 195

Configuration Command Reference

7

Postamble Purpose:

Configuration:

Sets the postamble that is appended to any data you scan with the 502X. Common postambles include cursor controls, such as tabs or carriage return line feeds. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

Yes

No

In the Configuration or Configuration Management application, choose Configure and then Data Collection. Next, choose Virtual Wedge and finally choose Postamble. On Cold Boot: SNMP OID: Syntax:

Not saved 1.3.6.1.4.1.1963.15.3.2.1.1.4.1 AEdata You only use the two-character command AE for bar code configuration labels. Acceptable values for data are up to 31 ASCII characters. Embedded null (<NUL>) characters are not allowed. If you enter the AE command without data, the postamble is disabled. If you are entering quotation marks as data or grouping configuration commands, you need to enclose the data within quotation marks (see the example). Note: To scan a bar code label that includes quotes, you must configure the 502X to use Code 39 in Full ASCII mode. For help, see “Code 39” earlier in this chapter.

Default: Scan:

Tab character (\t) To disable the postamble, scan this bar code: Disable Postamble

*$+AE* *$+AE*

7-67

Page 196

502X Data Collection PC System Manual

Postamble (continued)

Or:

To set the postamble to an ASCII character setting: 1. Scan this bar code: Enter Accumulate Mode / Set Postamble

*+/$+AE* *+/$+AE*

2. Scan a value for data from the “Full ASCII Bar Code Chart” in Appendix B. The postamble can be from 1 to 31 characters. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

Example:

You want to set a postamble that includes quotation marks. Enter the postamble by scanning this full ASCII bar code label: Set Postamble to “B”

*/D/KAE/B/B/BB/B/B/B* *$+AE"""B"""*

You must enclose the data within quotation marks and precede each quotation mark with another quotation mark so that the quotation marks are not treated as the end of the data.

7-68

Page 197

Configuration Command Reference

7

Power Management Purpose:

Configuration:

Enables or disables Power Management in the 802.11b HR radio. If you enable Power Management, the radio conserves power by sleeping between messages. Enabling Power Management decreases the performance of the RF network, but it increases the life of battery-powered devices. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

No

No

In the Configuration or Configuration Management application, choose Configure and then Network. Next, choose Radio, then Radio, and finally choose Power Management. On Cold Boot: SNMP OID:

Saved 1.2.840.10036.1.1.1.8.ifindex where ifindex is the radio adapter card number.

Options:

Acceptable values for Power Management parameter are: 1 2

Default:

Disabled Enabled

Enabled

Preamble Purpose:

Configuration:

Sets the preamble that precedes any data you scan with the 502X. Common preambles include a data location number or an operator number. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

Yes

No

In the Configuration or Configuration Management application, choose Configure and then Data Collection. Next, choose Virtual Wedge and finally choose Preamble.

7-69

Page 198

502X Data Collection PC System Manual

Preamble (continued)

On Cold Boot: SNMP OID: Syntax:

Not saved 1.3.6.1.4.1.1963.15.3.2.1.1.3.1 ADdata You only use the two-character command AD for bar code configuration labels. Acceptable values for data are up to 31 ASCII characters. Embedded null (<NUL>) characters are not allowed. When you enter the AD command without data, the preamble is disabled. If you are entering quotation marks as data or grouping configuration commands, you need to enclose the data within quotation marks (see the example). Note: To scan a bar code label that includes quotes, you must configure the 502X to use Code 39 in Full ASCII mode. For help, see “Code 39” earlier in this chapter.

Default: Scan:

No characters (disabled) To disable the preamble, scan this bar code: Disable Preamble

*$+AD* *$+AD*

Or:

To set the preamble to an ASCII character string: 1. Scan this bar code: Enter Accumulate Mode / Set Pream ble

*+/$+AD* *+/$+AD*

2. Scan a value for data from the “Full ASCII Bar Code Chart” in Appendix B. The preamble can be from 1 to 31 characters. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

7-70