Page 149

Configuration Command Reference

7

Codabar (continued)

Scan:

One of these bar codes: Disabled, Discard Start/Stop

ABC, Retain ABCD Start/Stop (5020 only)

*$+CD00*

*$+CD11*

ABC, Retain DC1-DC4 Start/Stop (5020 only)

Standard, Discard Start/Stop

*$+CD00*

*$+CD11*

*$+CD12*

*$+CD20*

*$+CD12*

*$+CD20*

Standard, Retain ABCD Start/Stop

Standard, Retain DC1-DC4 Start/Stop

*$+CD21*

*$+CD22*

*$+CD21*

*$+CD22*

Concatenated, Discard Start/Stop (5020 only)

*$+CD30* *$+CD30*

Concatenated, Retain ABCD Start/Stop (5020 only)

*$+CD31* *$+CD31*

Concatenated, Retain DC1-DC4 Start/Stop (5020 only)

*$+CD32*

*$+CD32*

Code 11 (5020 only) Purpose:

Configuration:

Enables or disables decoding of Code 11, a very high density, discrete numeric bar symbology. It is most extensively used in labeling telecommunications components and equipment. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

Yes

No

7-21

Page 150

502X Data Collection PC System Manual

Code 11 (continued)

In the Configuration or Configuration Management application, choose Configure and then Data Collection. Next, choose Symbologies and then choose Code 11. On Cold Boot: SNMP OID: Syntax:

Not saved 1.3.6.1.4.1.1963.15.3.3.1.1.8.1 CGdata You only use the two-character command CG for bar code configuration labels. Acceptable values for data are: 0 1 2

Default: Scan:

Disabled Code 11 enabled with one check digit Code 11 enabled with two check digits

Enabled with two check digits One of these bar codes: Disable Code 11

*$+CG0* *$+CG0*

Code 11 Enabled With One Check Digit

*$+CG1* *$+CG1*

Code 11 Enabled With Two Check Digits

*$+CG2* *$+CG2*

Notes:

7-22

Code 11 is designed to have one or two check digits with second check digit as optional. For reading reliability, the two-check-digit is recommended. Because of the ways that the check digits are calculated, selecting one check digit enables reading labels with either one or two check digits. Selecting two check digits, however, enables reading only labels with two check digits.

Page 151

Configuration Command Reference

7

Code 16K (5020 only) Purpose:

Configuration:

Enables or disables decoding of Code 16K, a two-dimensional (stacked rows), high density symbology. Based on Code 128, Code 16K is widely used to label unit-dose packaging for the healthcare industry. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

Yes

No

In the Configuration or Configuration Management application, choose Configure and then Data Collection. Next, choose Symbologies and then choose Code 16K. On Cold Boot: SNMP OID: Syntax:

Not saved 1.3.6.1.4.1.1963.15.3.3.1.1.16.1 CPdata You only use the two-character command CP for bar code configuration labels. Acceptable values for data are: 0 1 2

Disabled Standard Code 16K enabled Code 16K enabled with Function Code 1

When you enable Code 16K with Function Code 1, the 502X decodes the bar code label and checks for a Function Code 1 in the first data character position. If a Function Code 1 is the first character, the computer substitutes this Code 16K symbology identifier string for the Function Code 1 character: ]K1

Default: Scan:

Standard Code 16K enabled One of these bar codes: Disable Code 16K

Standard Code 16K Enabled

*$+CP0*

*$+CP1*

*$+CP0*

*$+CP1*

Code 16K Enabled With Function Code 1

*$+CP2* *$+CP2*

7-23

Page 152

502X Data Collection PC System Manual

Code 2 of 5 Purpose:

Enables or disables decoding of Code 2 of 5 symbology. Code 2 of 5 uses the bars to encode information and the spaces to separate the individual bars. This code is discrete and self-checking. Note: For the 5020 only, you can enable Code 2 of 5 only if the Interleaved 2 of 5 (I 2 of 5) code is disabled. If you enable I 2 of 5, Code 2 of 5 is automatically disabled.

Configuration:

Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

Yes

No

In the Configuration or Configuration Management application, choose Configure and then Data Collection. Next, choose Symbologies and then choose Code 2 of 5. On Cold Boot: SNMP OID: Syntax:

Not saved 1.3.6.1.4.1.1963.15.3.3.1.1.4.1 CCdata where data consists of three digits as follows: First digit:

0 1

Code 2 of 5, 3 Bar Start/Stop (5020 only) Code 2 of 5, 2 Bar Start/Stop

Second and third digits:

00 01-32

Disable Code 2 of 5 Label Length

You only use the two-character command CC for bar code configuration labels. Default: Scan:

Disabled To disable Code 2 of 5, scan this bar code: Disable Code 2 of 5

*$+CC000* *$+CC000*

7-24

Page 153

Configuration Command Reference

7

Code 2 of 5 (continued)

Or:

To enable Code 2 of 5: 1. Scan one of these bar codes: Code 2 of 5, 3 Bar Start/Stop

*+/$+CC0* *+/$+CC0*

Code 2 of 5, 2 Bar Start/Stop (5020 only)

*+/$+CC1* *+/$+CC1*

2. Scan a two-digit numeric value to set the label length (01-32) from these bar codes.

*0*

*1*

*2*

*3*

*0*

*2*

*4* *4*

*6* *6*

*8* *8*

*1*

*3*

*5*

*5*

*7*

*7*

*9*

*9*

3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

7-25

Page 154

502X Data Collection PC System Manual

Code 39 Purpose:

Enables or disables decoding of Code 39 symbology. Code 39 is discrete, self-checking, and of variable length. The character set is uppercase A to Z, 0 to 9, dollar sign ($), period (.), slash (/), percent (%), space ( ), plus (+), and minus (-). The 502X decodes the following three types of ASCII: •

Code 39 non-full ASCII

•

Code 39 full ASCII

•

Code 39 mixed-full ASCII (5020 only)

Non-full ASCII uses a one-character encoding scheme. For example, you encode the data “SAMPLE” as follows: Code 39 non-full ASCII

*SAMPLE* *SAMPLE*

This label decodes as SAMPLE. Full ASCII uses a two-character encoding scheme to extend the character set to 128 characters. You use the dollar sign ($), slash (/), percent (%), or plus (+) followed by an uppercase letter to represent one of the characters in the extended set. You must encode lowercase letters as a plus sign (+) followed by their uppercase equivalents. For a list of ASCII characters and their Code 39 representations, see the “Full ASCII Table” in Appendix B. Code 39 full ASCII

Use Code 39 full ASCII to enter ASCII control characters or lowercase characters as data. You should also enable Code 39 full ASCII to use ASCII command characters. For example, you encode the data “sample” in Code 39 full ASCII as follows:

*+S+A+M+P+L+E* *+S+A+M+P+L+E*

In Code 39 non-full ASCII, this label decodes as +S+A+M+P+L+E. In Code 39 full ASCII, this label decodes as sample. Use mixed-full ASCII when printers encode the same label two different ways. For example, if you have a bar code with the data $%a, some printers encode the data as follows: Code 39 mixed-full ASCII (5020 only)

*/D/E+A* */D/E+A*

7-26

Page 155

Configuration Command Reference

7

Code 39 (continued)

In the Full ASCII Table in Appendix B, /D represents $ and /E represents %. If you configure the 502X for Code 39 full ASCII, the computer decodes the data as $%a because there are three valid full ASCII character pairs to represent the data. Other printers encode the data $%a as:

*$%+A* *$%+A*

The $ and % are valid Code 39 characters in the non-full ASCII character set. However, the 502X will not decode this label if it is configured for full ASCII, because the data is not represented by valid full ASCII character pairs. To decode the label correctly, you need to configure the 502X for mixed-full ASCII. When you configure the 502X for Code 39 mixed-full ASCII, the 502X will decode both of the labels above as $%a. Mixed-full ASCII interprets any valid full ASCII character pairs that appear in the label, but does not require that all data be encoded with a valid full ASCII character pair. If you are uncertain how your labels are encoded, configure the 502X for mixed-full ASCII, which decodes all valid Code 39 labels. If you configure the 502X for Code 39 full ASCII, you should check for Code 39 mixed-full ASCII. Mixed-full ASCII does not apply when you configure the computer for non-full ASCII. Note: The interpretive text shown under bar code labels does not always accurately reflect the data that is encoded in the label. The interpretive text represents how the label should be decoded. Use this table to help configure your 502X. Code 39 Option

Bar Code Label

Decodes

Non-full ASCII

$%+A /D/E+A

$%+A /D/E+A

Full ASCII

$%+A /D/E+A

No decode $%a

Mixed-full ASCII (5020 only)

$%+A /D/E+A

$%a $%a

7-27

Page 156

502X Data Collection PC System Manual

Code 39 (continued)

Configuration:

Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

Yes

No

In the Configuration or Configuration Management application, choose Configure and then Data Collection. Next, choose Symbologies and then choose Code 39. On Cold Boot: SNMP OID: Syntax:

Not saved 1.3.6.1.4.1.1963.15.3.3.1.1.3.1 CBdata You only use the two-character command CB for bar code configuration labels. Acceptable values for data must be three digits, corresponding to: First digit:

0 1 2 3 4

Disabled Enabled with no check digit Enabled with check digit HIBC (Health Industry Bar Code) (5020 only) With AIAG check digit

Second digit:

0 1

Discard check digit Transmit check digit

Third digit:

0 1 2

Code 39 non-full ASCII Code 39 full ASCII (5020 only) Code 39 mixed-full ASCII

Note: Selecting HIBC Code 39 automatically sets the configuration to non-full ASCII with the check digit transmitted. Default: Scan:

Enable Code 39 Full ASCII with no check digit (101) To disable Code 39: Disable Code 39

*$+CB0* *$+CB0*

7-28

Page 157

Configuration Command Reference

7

Code 39 (continued)

Or:

To enable Code 39: 1. Scan this bar code: Enter Accumulate Mode / Enable Code 39

*+/$+CB* *+/$+CB*

2. Scan one of these bar codes to set the first digit: Without a Check Digit

*1*

With a Check Digit

*2*

*1*

*2*

HIBC Code 39

With AIAG Check Digit (5020 only)

*3*

*4*

*3*

*4*

3. Scan one of these bar codes to set the second digit: Discard Check Digit

Transmit Check Digit

*0*

*1*

*0*

*1*

4. Scan one of these bar codes to set the third digit: Code 39 Non-Full ASCII

Code 39 Full ASCII

*0*

*1*

*0*

*1*

Code 39 Mixed-Full ASCII (5020 only)

*2* *2*

5. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

7-29

Page 158

502X Data Collection PC System Manual

Code 49 (5020 only) Purpose:

Enables or disables decoding of Code 49, a multirow symbology for high data density. The last character in each row is used for row checking, and the last two characters of the symbol are used for overall checking. Function codes designate where to place the predefined data string in a Code 49 label. Whenever a 5020 encounters a function code, it replaces the function code with the defined string before transmitting the data. A single Code 49 symbol may contain several different variable length data fields. Function Code 1 (F1) identifies a data system. Function Code 2 (F2) indicates the end of a data field.

Configuration:

Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

Yes

No

In the Configuration or Configuration Management application, choose Configure and then Data Collection. Next, choose Symbologies and then choose Code 49. On Cold Boot: SNMP OID:

Syntax:

Not saved 1.3.6.1.4.1.1963.15.3.3.1.1.11.1 1.3.6.1.4.1.1963.15.3.3.1.1.12.1 1.3.6.1.4.1.1963.15.3.3.1.1.13.1 1.3.6.1.4.1.1963.15.3.3.1.1.14.1 CJdata CKdata CLdata CMdata

Code 49 Function Code 1 Function Code 2 Function Code 3

Code 49 Function Code 1 Function Code 2 Function Code 3

You only use the two-character command CJ, CK, CL, or CM for bar code configuration labels. Acceptable values for data are:

7-30

Code 49:

0 1

Disabled Enabled

Function Code 1:

Any two ASCII characters

Function Code 2:

Any four ASCII characters

Function Code 3:

Any two ASCII characters