Configuration Command Reference
7
Code 49 (continued)
Default:
Scan:
Code 49 Function Code 1 Function Code 2 Function Code 3
Enabled NULL CR LF (\r\n) NULL
One of these bar codes: Disable Code 49
Enable Code 49
*$+CJ0*
*$+CJ1*
*$+CJ0*
Scan:
*$+CJ1*
To disable any of the function codes, scan one of these bar codes: Disable Function Code 1
*$+CK* *$+CK*
Disable Function Code 2
*$+CL*
*$+CL*
Disable Function Code 3
*$+CM* *$+CM*
Or:
To set one of the function codes to a character string: 1. Scan one of these bar codes: Enter Accumulate Mode / Set Function Code 1
*+/$+CK* *+/$+CK*
Enter Accumulate Mode / Set Function Code 2
*+/$+CL* *+/$+CL*
Enter Accumulate Mode / Set Function Code 3
*+/$+CM* *+/$+CM*
7-31
Page 160
502X Data Collection PC System Manual
Code 49 (continued)
2. Scan any character from the “Full ASCII Bar Code Chart” in Appendix B. You can define two characters each for Function Codes 1 and 3, and four characters for Function Code 2. 3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
Code 93/93i Purpose:
Enables or disables decoding of Code 93/93i, a variable length, continuous symbology that uses four element widths. Code 93i (available only on 5020) is an upwardly compatible superset of Code 93 offering support for numeric compression, binary data, error correction, composite labels, and other features.
Configuration:
Use one of these methods: Configuration Applications
SNMP
Bar Codes
Fast Config
Yes
Yes
Yes
No
In the Configuration or Configuration Management application, choose Configure and then Data Collection. Next, choose Symbologies and then choose Code 93/93i. On Cold Boot: SNMP OID: Syntax:
Not saved 1.3.6.1.4.1.1963.15.3.3.1.1.7.1 CFdata You only use the two-character command CF for bar code configuration labels. Acceptable values for data are: 0 1
Default:
7-32
Disabled Enabled
Enabled
Page 161
Configuration Command Reference
7
Code 93/93i (continued)
Scan:
One of these bar codes: Disable Code 93/93i
*$+CF0* *$+CF0*
Enable Code 93/93i
*$+CF1* *$+CF1*
Code 128 Purpose:
Configuration:
Enables or disables decoding of Code 128, a very high density alphanumeric symbology that supports the extended ASCII character set. It is a variable length, continuous code that uses multiple element widths. Use one of these methods: Configuration Applications
SNMP
Bar Codes
Fast Config
Yes
Yes
Yes
No
In the Configuration or Configuration Management application, choose Configure and then Data Collection. Next, choose Symbologies and then choose Code 128. On Cold Boot: SNMP OID: Syntax:
Not saved 1.3.6.1.4.1.1963.15.3.3.1.1.9.1 CHdata You only use the two-character command CH for bar code configuration labels. Acceptable values for data are: 0 1 2
Default:
Disabled Standard Code 128 UCC/EAN Code 128
Standard
7-33
Page 162
502X Data Collection PC System Manual
Code 128 (continued)
Scan:
One of these bar codes: Disable Code 128
*$+CH0* *$+CH0*
Enable Standard Code 128
*$+CH1* *$+CH1*
Enable UCC/EAN Code 128
*$+CH2* *$+CH2*
Note: If you configure Standard Code 128, the 502X will not decode Function Code 1 characters in the first position of a bar code label. Any subsequent Function Code 1 characters are translated to the ASCII GS character as a separator for variable length fields. If you configure UCC/EAN Code 128, the 502X will decode a bar code label as Standard Code 128 unless one of the first two characters are a start character and a Function Code 1. In this case, the bar code label is processed as described next: 1. The Function Code 1 character is not transmitted. 2. The three symbology ID characters, ]C1, are transmitted. 3. The remaining Code 128 characters are decoded as Standard Code 128.
7-34
Page 163
Configuration Command Reference
7
Controller Connect Check Receive Timer Purpose:
When the 502X is inactive, it still sends messages to the DCS 30X to check the RF or Ethernet connection. If no message is received within the time set for the Controller Connect Check Receive Timer, the 502X is no longer connected to the DCS 30X and the Data Buffered icon flashes. The timer countdown resets each time a valid message is received. Power Management Tip: Intermec strongly recommends that you use the optimum setting of 45 seconds.
Configuration:
Use one of these methods: Configuration Applications
SNMP
Bar Codes
Fast Config
Yes
Yes
No
No
In the Configuration or Configuration Management application, choose Configure and then Network. Next, choose Protocols, then UDP Plus, and finally choose Connect Rcv Timer. On Cold Boot: SNMP OID:
Not saved 1.3.6.1.4.1.1963.5.15.20.1.1.1.5.1
Options:
Acceptable values for the receive timer are any number from 1 to 3600 seconds (60 minutes).
Default:
45 seconds
7-35
Page 164
502X Data Collection PC System Manual
Controller Connect Check Send Timer Purpose:
When the 502X is inactive, it still sends messages to the DCS 30X to check the RF or Ethernet connection. The 502X sends a message at the time interval set for the Controller Connect Check Send Timer. The timer countdown resets each time a valid message is sent or received. Power Management Tip: Intermec strongly recommends that you use the optimum setting of 20 seconds.
Configuration:
Use one of these methods: Configuration Applications
SNMP
Bar Codes
Fast Config
Yes
Yes
No
No
In the Configuration or Configuration Management application, choose Configure and then Network. Next, choose Protocols, then UDP Plus, and finally choose Connect Send Timer. On Cold Boot: SNMP OID:
7-36
Not saved 1.3.6.1.4.1.1963.5.15.20.1.1.1.6.1
Options:
Acceptable values for the send timer are any number from 1 to 3600 seconds (60 minutes).
Default:
20 seconds
Page 165
Configuration Command Reference
7
Controller IP Address Purpose:
Configuration:
Defines the IP address assigned to the DCS 30X in your network. An IP address is a network level address you assign to each device in a TCP/IP network. The controller IP address you set on the 502X must match the address that is set on the DCS 30X. You must set the controller IP address even if you plan to enable DHCP (Dynamic Host Configuration Protocol). Use one of these methods: Configuration Applications
SNMP
Bar Codes
Fast Config
Yes
Yes
No
No
In the Configuration or Configuration Management application, choose Configure and then Network. Next, choose Protocols, then UDP Plus, and finally choose Controller IP Address. On Cold Boot: SNMP OID: Options:
Not saved 1.3.6.1.4.1.1963.5.15.20.1.1.1.11.1 This address must be a valid IPv4 address that has the form y.x.x.x where y is a value between 1 and 223 (not including 127) and x is a value between 0 and 255. Default:
0.0.0.0
Decode Priority (5020 only) Purpose:
Defines the decode priority to use when decoding bar code symbologies. The 5020 uses an initial order to decode the symbology of each bar code label. As bar code labels are decoded, the 5020 attempts to decode the labels in an order determined by the frequency of past decoded symbologies, that is, the most frequently decoded symbology is attempted first, then the second most, and so on.
7-37
Page 166
502X Data Collection PC System Manual
Decode Priority (continued)
For example, if you have only been scanning Code 39 bar code labels, the 5020 will set the decode priority to Code 39 and will first attempt to decode every label as Code 39. If you suddenly begin scanning only Code 128 bar code labels, the 5020 eventually resets the decode priority. Although you can set the decode priority, the 5020 establishes the priority order based on the bar code labels you scan. You can also reset the statistics through SNMP or an SDK application so that the 5020 can establish a fresh set of decode statistics. Configuration:
Use one of these methods: Configuration Applications
SNMP
Bar Codes
Fast Config
Yes
Yes
Yes
No
In the Configuration or Configuration Management application, choose Configure and then Data Collection. Next, choose Decode Options and then choose Decode Priority. On Cold Boot: SNMP OID: Syntax:
Not saved 1.3.6.1.4.1.1963.15.3.3.2.1.3.1 CTdata You only use the two-character command CT for bar code configuration labels. Acceptable values for data are from 2 to 24 numbers from this list: 01 02 03 04 05 06 07 08 09 10 11 12
Code 39 Code 93/93i Code 49 Interleaved 2 of 5 Codabar UPC/EAN Code 128 Code 16K Plessey Code 11 MSI PDF 417
You must enter leading zeros, and you cannot duplicate numbers. Default:
7-38
010203040506070809101112
Page 167
Configuration Command Reference
7
Decode Priority (continued)
Scan:
To set the decode priority to the default, scan this bar code: Set Decode Priority to Default
*$+CT00* *$+CT00*
Or:
To set the decode priority: 1. Scan this bar code: Enter Accumulate Mode / Set Decode Priority
*+/$+CT* *+/$+CT*
2. Scan one bar code at a time (up to a total of all 12) in the order you want to set for the decode priority: Code 39
Code 93/93i
*01*
*02*
Code 49
Interleaved 2 of 5
*03*
*04*
Codabar
UPC/EAN
*05*
*06*
Code 128
Code 16K
*07*
*08*
Plessey
Code 11
*01*
*03*
*05*
*07*
*09*
*02*
*04*
*06*
*08*
*10*
*09*
*10*
MSI
PDF 417
*11* *11*
*12*
*12*
7-39
Page 168
502X Data Collection PC System Manual
Decode Priority (continued)
3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
Decode Security Purpose:
Defines the security level to use when decoding bar codes. When you select a lower decode security level, the 502X can decode bar codes with poorer print quality. Note: Use the low parameter as only a temporary solution until you can improve the bar code label print quality.
Configuration:
Use one of these methods: Configuration Applications
SNMP
Bar Codes
Fast Config
Yes
Yes
Yes
No
In the Configuration or Configuration Management application, choose Configure and then Data Collection. Next, choose Decode Options and then choose Decode Security Level. On Cold Boot: SNMP OID: Syntax:
Not saved 1.3.6.1.4.1.1963.15.3.3.3.1.1.10.1.1 CSdata You only use the two-character command CS for bar code configuration labels. Acceptable values for data are: 0 1 2
Default:
7-40
Low Moderate High
Moderate