Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 17 of 33

502X Data Collection PC System Manual: Chapter 7: Configuration Command Reference, pages 139 to 148

Pages 139 to 148 of 310, from 502X Data Collection PC System Manual

The original document is the PDF (2.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 5020

Page 139

Configuration Command Reference

7

Access Point Density Purpose:

Configuration:

This parameter controls the roaming sensitivity of the 802.11b HR radio. By increasing the density you do not reduce the absolute range of the radio, but the roaming algorithms are modified to allow significant overlap of the wireless cells. Increasing the density allows you to create a higher performance radio network but requires significantly more access points to cover a given area. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

No

No

In the Configuration or Configuration Management application, choose Configure and then Network. Next, choose Radio, then Radio, and finally choose Access Point Density. On Cold Boot: SNMP OID:

Saved 1.3.6.1.4.1.1963.5.5.2.4.1.1.5.ifindex where ifindex is the radio adapter card number.

Options:

Acceptable values for Access Point Density are: 1 2 3

Default:

Low Density Medium Density High Density

Low Density

7-11

Page 140

502X Data Collection PC System Manual

Access Point MAC Address Purpose:

Displays the MAC address of the radio in the access point to which the 502X is currently connected.

Configuration:

The Access Point MAC Address is a read-only parameter that cannot be changed.

On Cold Boot:

Not applicable (read-only)

SNMP OID:

1.3.6.1.4.1.1963.5.5.2.5.1.1.2.index

OpenAir radio

1.3.6.1.4.1.1963.5.5.2.4.1.1.2.ifindex

802.11b HR radio where index or ifindex is the radio adapter card number. Default:

None

Access Point Name (5020 only) Purpose:

Configuration:

Displays the first 11 characters of the name of the access point to which the 502X is currently connected. The Access Point Name is a read-only parameter that cannot be changed. In the Configuration or Configuration Management application, choose Configure and then Network. Next, choose Radio, then Radio, and finally choose Access Pt Name. Choose Refresh to view the current assignments.

On Cold Boot: SNMP OID:

Not applicable (read-only) 1.3.6.1.4.1.1963.5.5.2.5.1.1.1.index where index is the radio adapter card number.

Default:

7-12

None

Page 141

Configuration Command Reference

7

Access Point Network Name Purpose:

Configuration:

This parameter is an alphanumeric string (maximum of 32 ASCII characters) that must match the network name of the access point(s) to which your 502X should associate. The Access Point Network Name is a read-only parameter that cannot be changed. In the Configuration or Configuration Management application, choose Configure and then Network. Next, choose Radio, then Radio, and finally choose Access Point Network Name.

On Cold Boot: SNMP OID:

Not applicable (read-only) 1.3.6.1.4.1.1.1963.5.5.2.4.1.1.1.ifindex where ifindex is the radio adapter card number.

Default:

None

Acknowledgement Delay Lower Limit Purpose:

Configuration:

When the 502X sends a message to the DCS 30X, the 502X waits to receive a response acknowledging the message. If no response is received within the Acknowledgement Delay Lower Limit time, the 502X sends the message again at the time interval set for the lower limit. The 502X will continue to send the data at increasingly longer intervals until it reaches the Acknowledgement Delay Upper Limit time. The 502X continues sending the message at the time interval set for the upper limit until a response is received or a timeout error occurs. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

No

No

In the Configuration or Configuration Management application, choose Configure and then Network. Next, choose Protocols, then UDP Plus, and finally choose Ack Delay Low Limit. On Cold Boot: SNMP OID:

Not saved 1.3.6.1.4.1.1963.5.15.20.1.1.1.2.1

Options:

Acceptable values for the lower limit are any number from 200 to 2000 ms.

Default:

300 ms

7-13

Page 142

502X Data Collection PC System Manual

Acknowledgement Delay Upper Limit Purpose:

Configuration:

When the 502X sends a message to the DCS 30X, the 502X waits to receive a response acknowledging the message. If no response is received within the Acknowledgement Delay Lower Limit time, the 502X sends the message again at the time interval set for the lower limit. The 502X will continue to send the data at increasingly longer intervals until it reaches the Acknowledgement Delay Upper Limit time. The computer continues sending the message at the time interval set for the upper limit until a response is received or a timeout error occurs. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

No

No

In the Configuration or Configuration Management application, choose Configure and then Network. Next, choose Protocols, then UDP Plus, and finally choose Ack Delay Upper Limit. On Cold Boot: SNMP OID:

7-14

Not saved 1.3.6.1.4.1.1963.5.15.20.1.1.1.3.1

Options:

Acceptable values for the upper limit are any number from 2 to 60 seconds.

Default:

5 seconds

Page 143

Configuration Command Reference

7

Automatic Shutoff Purpose:

Defines the maximum length of time the 502X remains on when there is no activity. When you do not use the 502X for the length of time set with this command, the computer automatically turns off.

'

When you press to turn on the 502X, the PC either resumes exactly where it was when you turned it off or boots and restarts your application. You can use the Configuration application, the Configuration Management application, or the Power applet in the Control Panel to set the Automatic Shutoff parameter. In the Configuration and Configuration Management applications, the value you set will turn off the 502X when you are using it on battery power. In the Control Panel, you can set separate values to turn off the 502X when it is on battery power or on AC power. If the 502X is connected to AC power through the D5020 or L5020, automatic shutoff is disabled unless you enable the suspend while on external power in the Control Panel Power applet. For help, see Chapter 3, “Customizing the 502X Using the Control Panel.” Power Management Tip: You should use the Automatic Shutoff feature to preserve the main battery pack’s power. Configuration:

Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

Yes

No

In the Configuration or Configuration Management application, choose Configure and then Unit. Next, choose Power Management and then choose Automatic Shutoff. On Cold Boot: SNMP OID: Syntax:

Not saved 1.3.6.1.4.1.1963.15.11.3.0 EZdata You only use the two-character command EZ for bar code configuration labels. When configuring via SNMP, acceptable values for data are: 0 1 5 30 60

Disabled (always on) 1 minute 5 minutes 30 minutes 60 minutes

7-15

Page 144

502X Data Collection PC System Manual

Automatic Shutoff (continued)

Default: Scan:

5 minutes One of these bar codes: Disable Automatic Shutoff

Automatic Shutoff 1 Minute

*$+EZ0*

*$+EZ1*

Automatic Shutoff 5 Minutes

Automatic Shutoff 30 Minutes

*$+EZ5*

*$+EZ30*

*$+EZ0*

*$+EZ1*

*$+EZ5*

*$+EZ30*

Automatic Shutoff 60 Minutes

*$+EZ60* *$+EZ60*

Beep Duration (5020 only) Purpose:

Defines the duration of the beeps on the 5020. There are two types of beeps: • •

Configuration:

Low beep High beep

Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

Yes

No

In the Configuration or Configuration Management application, choose Configure and then Unit. Next, choose Speaker and then choose either Low Beep Duration or High Beep Duration. On Cold Boot: SNMP OID:

Syntax:

7-16

Not saved 1.3.6.1.4.1.1963.15.3.1.4.1.2.1 1.3.6.1.4.1.1963.15.3.1.4.1.3.1 BBdata BCdata

Low beep duration High beep duration

Low beep duration High beep duration

Page 145

Configuration Command Reference

7

Beep Duration (continued)

You only use the two-character command BB or BC for bar code configuration labels. Acceptable values for data are from 10 to 60,000 ms (60 seconds). Default:

Scan:

50 ms for the low beep duration 60 ms for the high beep duration 1. Scan this bar code: Enter Accumulate Mode

*+/* *+/*

2. Scan one of these bar codes: Change Low Beep Duration

Change High Beep Duration

*$+BB*

*$+BC*

*$+BB*

*$+BC*

3. Scan a numeric value for data in milliseconds from these bar codes:

*0*

*1*

*2*

*3*

*0*

*2*

*4* *4*

*6* *6*

*8* *8*

*1*

*3*

*5*

*5

*7*

*7*

*9*

*9*

4. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

5. Repeat Steps 1 through 4 to set the other beep duration.

7-17

Page 146

502X Data Collection PC System Manual

Beep Frequency (5020 only) Purpose:

Defines the individual frequencies of the 5020 beeps. There are two types of beeps: • •

Configuration:

Low beep High beep

Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

Yes

No

In the Configuration or Configuration Management application, choose Configure and then Unit. Next, choose Speaker and then choose either Low Beep Frequency or High Beep Frequency. On Cold Boot: SNMP OID:

Syntax:

Not saved 1.3.6.1.4.1.1963.15.3.1.4.1.4.1 1.3.6.1.4.1.1963.15.3.1.4.1.5.1 BGdata BHdata

Low beep frequency High beep frequency

Low beep frequency High beep frequency

You only use the two-character command BG or BH for bar code configuration labels. Acceptable values for data are from 100 to 20,000 Hz (20 KHz). Note: If you set the frequency outside the range of 100 Hz to 10,000 Hz, the beeps are inaudible. Default:

1000 Hz for the low beep 2300 Hz for the high beep

Scan:

1. Scan this bar code: Enter Accumulate Mode

*+/* *+/*

2. Scan one of these bar codes: Change Low Beep Frequency

*$+BG* *$+BG*

7-18

Change High Beep Frequency

*$+BH*

*$+BH*

Page 147

Configuration Command Reference

7

Beep Frequency (continued)

3. Scan a numeric value for data in Hz from these bar codes:

*0*

*1*

*2*

*3*

*0*

*2*

*4* *4*

*6* *6*

*8* *8*

*1*

*3*

*5*

*5*

*7*

*7*

*9*

*9*

4. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

5. Repeat Steps 1 through 4 to set the other beep frequency.

7-19

Page 148

502X Data Collection PC System Manual

Codabar Purpose:

Configuration:

Enables or disables decoding of Codabar, a self-checking, discrete symbology. The American Blood Commission (ABC) Codabar requires that you retain and transmit the start/stop code digits when processing a Codabar symbol. As a result, configuration CD10 is an illegal configuration. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

Yes

No

In the Configuration or Configuration Management application, choose Configure and then Data Collection. Next, choose Symbologies and then choose Codabar. On Cold Boot: SNMP OID: Syntax:

Not saved 1.3.6.1.4.1.1963.15.3.3.1.1.5.1 CDdata You only use the two-character command CD for bar code configuration labels. Acceptable values for data must be two digits, corresponding to:

Default:

7-20

First digit:

0 1 2 3

Disabled (5020 only) ABC Standard (5020 only) Concatenated

Second digit:

0 1 2

Discard Start/Stop Retain ABCD Start/Stop (5020 only) Retain DC1-DC4 Start/Stop

Standard, Transmit ABCD start/stop