Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 16 of 33

502X Data Collection PC System Manual: Chapter 7: Configuration Command Reference, pages 129 to 138

Pages 129 to 138 of 310, from 502X Data Collection PC System Manual

The original document is the PDF (2.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 5020

Page 129

7 Configuration Command Reference

Page 130

Blank page

Page 131

Configuration Command Reference

7

This chapter describes all configuration commands supported on the 502X.

Using Configuration Commands A configuration command changes the way the 502X operates. For example, to make the 502X beep very loud in a noisy environment, you can send a command to change the Beep Volume. To execute configuration commands, you can • send the command from an application, such as the Configuration application or Configuration Management. You can also send a command from your own application. For help, see Chapter 5, “Developing and Installing Applications.”

• send the command from an SNMP management station. For help with SNMP, see “Configuring the 502X by Using SNMP” in Chapter 2.

• send the command from a device in a UDP Plus network. For help, see your DCS 30X user’s manual.

• scan the command from a Code 39 or Code 93/93i bar code label. For more information, see “Configuring the 502X by Scanning Bar Code Labels” in Chapter 2 of your user’s manual.

You can find the following information about each configuration command in this chapter: Purpose

Describes the command and its function.

Configuration

Lists the possible ways to send the command, including

• the Configuration Management application in Unit Manager (Unit Management on 5023). For help, see “Using Configuration Management” in Chapter 4.

• the Fast Config and Configuration applications. For help, see Chapter 2 of your user’s manual.

•

SNMP, including SNMP OID where applicable

• bar codes, including Code 39 bar code labels where applicable

Syntax

If configurable by bar code, the two-character code for the command.

Options

Acceptable values for the command.

Default

Factory default setting for the command.

The configuration commands are listed alphabetically by command name. For a list of commands by category, see the next section, “Configuration Commands Listed by Category.” If you want to look up a command by its syntax, see “Configuration Commands Listed by Bar Code Syntax” later in this chapter. Note: The Code 39 bar code labels in this chapter show an asterisk (*) at the beginning and end of the human-readable interpretation to represent the start and stop codes. If you are creating your own Code 39 bar code labels, your bar code printing utility may automatically supply the asterisks as the start/stop code.

7-3

Page 132

502X Data Collection PC System Manual

Configuration Commands Listed by Category Use this next list to find the configuration commands you may need to set for data collection, IDRS, Internet Explorer (IE), network and RF communications, SNMP, TFTP, UDP Plus, or the unit (502X). Data Collection

Codabar, 7-20

Plessey (5020 only), 7-66

Code 11 (5020 only), 7-21

Postamble, 7-67

Code 16K (5020 only), 7-23

Preamble, 7-69

Code 2 of 5, 7-24

Scanner Mode (5020 only), 7-77

Code 39, 7-26

Scanner Redundancy, 7-78

Code 49 (5020 only), 7-30

Scanner Selection (5020 only), 7-79

Code 93/93i, 7-32

Scanner Timeout, 7-81

Code 128, 7-33

Scanner Trigger, 7-82

Decode Priority (5020 only), 7-37

Symbology Identifier, 7-98

Decode Security, 7-40

UPC/EAN, 7-108

Interleaved 2 of 5, 7-55

Virtual Wedge, 7-112

MSI, 7-61

Virtual Wedge Code Page, 7-112

PDF 417, 7-65

Virtual Wedge Grid, 7-113

IDRS (5020 only)

IDRSEnable, 7-47

IDRSServerAddr, 7-48

IDRSRetries, 7-47

IDRSTimeout, 7-49

IDRSScope, 7-48

Internet Explorer (IE)

IE Autodial Name, 7-49

IE Proxy Server Port, 7-52

IE Cache Size, 7-50

IE Underline Links, 7-52

IE Function Key URLs, 7-50

IE Use LAN (No Auto Dial), 7-53

IE Home Page, 7-51

IE Use Proxy Server, 7-54

IE Proxy Server Address, 7-51

7-4

Page 133

Configuration Command Reference

7

Network

502X IP Address, 7-10

Secondary DNS Server, 7-83

Default Router, 7-41

Secondary WINS Server, 7-84

Device Name, 7-42

Subnet Mask, 7-96

DHCP (Obtain IP Address Via DHCP) , 7-43

TCP/IP Extensions Delayed Acknowledgement Timer, 7-103

Primary DNS Server, 7-71

TCP/IP Extensions Initial Roundtrip Time, 7-103

Primary WINS Server, 7-72

TCP/IP Extensions Receive Window Size, 7-104

OpenAir (5020 only)

Access Point MAC Address, 7-12

Radio ROM Version, 7-74

Access Point Name, 7-12

Roaming Allowed, 7-76

Domain, 7-46

Security Identification (ID) , 7-85

Inactivity Timeout, 7-54

Transmit Mode, 7-106

Radio MAC Address, 7-73

802.11b HR

Access Point Density, 7-11

Receive All Multicasts, 7-74

Access Point MAC Address, 7-12

Reservation Threshold, 7-75

Access Point Network Name, 7-13

Station Name, 7-96

Maximum Sleep Duration, 7-60

Supported WEP, 7-97

Network Name, 7-63

Transmit Rate, 7-107

Power Management, 7-69

WEP Encryption, 7-115

Primary/Station ROM Version, 7-72

WEP Key, 7-116

Radio Description, 7-73

WEP Key Length , 7-117

Radio MAC Address, 7-73

WEP Transmit Key, 7-117

7-5

Page 134

502X Data Collection PC System Manual

SNMP

Identification Contact, 7-86

Security Subnet Mask, 7-90

Identification Location, 7-86

Security Write Encryption, 7-91

Identification Name, 7-87

Trap Authentication, 7-92

Security Encryption Key, 7-87

Trap Community Name, 7-92

Security IP Address, 7-88

Trap IP Address, 7-93

Security Read Encryption, 7-89

Trap Port, 7-94

Security Read-Only Community String, 7-89

Trap Threshold, 7-94

Security Read/Write Community String, 7-90

TFTP

TFTP Resend Limit, 7-105

TFTP Timeout, 7-105

UDP Plus

Acknowledgement Delay Lower Limit, 7-13

Maximum Retries, 7-60

Acknowledgement Delay Upper Limit, 7-14

Network Loopback, 7-63

Controller Connect Check Receive Timer, 7-35

Network Port, 7-64

Controller Connect Check Send Timer, 7-36

UDP Plus Enable, 7-107

Controller IP Address, 7-37

Unit

Automatic Shutoff, 7-15

IrDA Baud Rate, 7-57

Beep Duration (5020 only), 7-16

Keypad Caps Lock, 7-58

Beep Frequency (5020 only), 7-18

Keypad Clicker, 7-59

Display Backlight Level, 7-44

Speaker Volume, 7-95

Display Backlight Timeout, 7-44

7-6

Page 135

Configuration Command Reference

7

Configuration Commands Listed by Bar Code Syntax The next table lists the configuration commands you can set by scanning bar codes with the 502X. The configuration commands are listed in alphabetic order by syntax. You can also configure these commands by using the Configuration application, the Configuration Management application in Unit Manager, or using SNMP. Syntax

Command

For Help, See Page

ADdata

Preamble

7-69

AEdata

Postamble

7-67

BVdata

Speaker Volume

7-95

BBdata

Low Beep Duration (5020 only)

7-16

BCdata

High Beep Duration (5020 only)

7-16

BGdata

Low Beep Frequency (5020 only)

7-18

BHdata

High Beep Frequency (5020 only)

7-18

CAdata

Interleaved 2 of 5 Code (I 2 of 5)

7-55

CBdata

Code 39

7-26

CCdata

Code 2 of 5 (2 of 5)

7-24

CDdata

Codabar

7-20

CEdata

UPC/EAN

7-108

CFdata

Code 93

7-32

CGdata

Code 11 (5020 only)

7-21

CHdata

Code 128

7-33

CIdata

Plessey (5020 only)

7-66

CJdata

Code 49 (5020 only)

7-30

CKdata

Code 49 Function Code 1 (5020 only)

7-30

CLdata

Code 49 Function Code 2 (5020 only)

7-30

CMdata

Code 49 Function Code 3 (5020 only)

7-30

CNdata

MSI

7-61

CPdata

Code 16K (5020 only)

7-23

CQdata

PDF 417

7-65

CSdata

Decode Security

7-40

CTdata

Decode Priority (5020 only)

7-37

CYdata

Symbology Identifier

7-98

DFdata

Display Backlight Timeout

7-44

7-7

Page 136

502X Data Collection PC System Manual

Bar Code Configuration Commands by Syntax (continued)

7-8

Syntax

Command

For Help, See Page

EZdata

Automatic Shutoff

7-15

KAdata

Keypad Caps Lock

7-58

KCdata

Keypad Clicker

7-59

SAdata

Scanner Timeout

7-81

SBdata

Scanner Mode (5020 only)

7-77

SCdata

Scanner Trigger

7-82

SRdata

Scanner Redundancy

7-78

SSdata

Scanner Selection (5020 only)

7-79

Page 137

Configuration Command Reference

7

Entering Variable Data in a Configuration Command You can enter variable data for many of the configuration commands. For example, you can set a preamble that is up to 31 ASCII characters long. Follow these general instructions to enter variable data. To enter variable data in a configuration command

1. Scan a bar code label with this syntax: +/$+command where: +/ is the syntax for the Enter Accumulate Mode command.

$+ is the syntax for the Change Configuration command.

command is the syntax and data for the command you want to change.

For example, the command syntax for a preamble is ADdata. To change or set a preamble, scan this bar code: Enter Accumulate Mode / Change Configuration / Set Preamble

*+/$+AD* *+/$+AD*

2. Scan a bar code label from the “Full ASCII Bar Code Chart” in Appendix B. If the data you enter forms a reader or configuration command such as BV for Speaker Volume, you must enclose the data in quotes. If you are entering quotation marks as data, you must enclose the data within quotation marks and precede each quotation mark with another quotation mark. For help, see “Configuring the 502X by Scanning Bar Code Labels” in Chapter 2 of your user’s manual. To set the preamble to the character T, scan this label: T

*T* *T*

Note: To use the bar code labels in Appendix B, you must configure the 502X to use Code 39 in Full ASCII mode. For help, see “Code 39” later in this chapter. 3. Scan the Exit Accumulate Mode bar code label to update the 502X’s configuration: Exit Accumulate Mode

*-/* *-/*

7-9

Page 138

502X Data Collection PC System Manual

502X IP Address Purpose:

Configuration:

Defines the IP address assigned to the 502X in your RF or Ethernet network. An IP address is a unique network level address you assign to each device in a TCP/IP network. If you are using a DHCP server, the IP address is automatically assigned. After you change this parameter, suspend and resume the 502X to make the change effective. Use one of these methods: Configuration Applications

SNMP

Bar Codes

Fast Config

Yes

Yes

No

Yes

In the Configuration or Configuration Management application, choose Configure and then Network. Next, choose either Radio or Ethernet, then IP Address, then Obtain IP Address via DHCP, and finally choose IP Address. On Cold Boot: SNMP OID:

Saved 1.3.6.1.4.1.1963.5.15.5.2.1.2.index where index is the radio or I/O adapter card number.

Options:

This address must be a valid IPv4 address that has the form y.x.x.x where y is a value between 1 and 223 (not including 127) and x is a value between 0 and 255. Default:

7-10

0.0.0.0