The text of a manual · part 16 of 33
502X Data Collection PC System Manual: Chapter 7: Configuration Command Reference, pages 129 to 138
Pages 129 to 138 of 310, from 502X Data Collection PC System Manual
The original document is the PDF (2.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 5020
Page 129
7 Configuration Command Reference
Page 130
Blank page
Page 131
Configuration Command Reference
7
This chapter describes all configuration commands supported on the 502X.
Using Configuration Commands A configuration command changes the way the 502X operates. For example, to make the 502X beep very loud in a noisy environment, you can send a command to change the Beep Volume. To execute configuration commands, you can • send the command from an application, such as the Configuration application or Configuration Management. You can also send a command from your own application. For help, see Chapter 5, “Developing and Installing Applications.”
• send the command from an SNMP management station. For help with SNMP, see “Configuring the 502X by Using SNMP” in Chapter 2.
• send the command from a device in a UDP Plus network. For help, see your DCS 30X user’s manual.
• scan the command from a Code 39 or Code 93/93i bar code label. For more information, see “Configuring the 502X by Scanning Bar Code Labels” in Chapter 2 of your user’s manual.
You can find the following information about each configuration command in this chapter: Purpose
Describes the command and its function.
Configuration
Lists the possible ways to send the command, including
• the Configuration Management application in Unit Manager (Unit Management on 5023). For help, see “Using Configuration Management” in Chapter 4.
• the Fast Config and Configuration applications. For help, see Chapter 2 of your user’s manual.
•
SNMP, including SNMP OID where applicable
• bar codes, including Code 39 bar code labels where applicable
Syntax
If configurable by bar code, the two-character code for the command.
Options
Acceptable values for the command.
Default
Factory default setting for the command.
The configuration commands are listed alphabetically by command name. For a list of commands by category, see the next section, “Configuration Commands Listed by Category.” If you want to look up a command by its syntax, see “Configuration Commands Listed by Bar Code Syntax” later in this chapter. Note: The Code 39 bar code labels in this chapter show an asterisk (*) at the beginning and end of the human-readable interpretation to represent the start and stop codes. If you are creating your own Code 39 bar code labels, your bar code printing utility may automatically supply the asterisks as the start/stop code.
7-3
Page 132
502X Data Collection PC System Manual
Configuration Commands Listed by Category Use this next list to find the configuration commands you may need to set for data collection, IDRS, Internet Explorer (IE), network and RF communications, SNMP, TFTP, UDP Plus, or the unit (502X). Data Collection
Codabar, 7-20
Plessey (5020 only), 7-66
Code 11 (5020 only), 7-21
Postamble, 7-67
Code 16K (5020 only), 7-23
Preamble, 7-69
Code 2 of 5, 7-24
Scanner Mode (5020 only), 7-77
Code 39, 7-26
Scanner Redundancy, 7-78
Code 49 (5020 only), 7-30
Scanner Selection (5020 only), 7-79
Code 93/93i, 7-32
Scanner Timeout, 7-81
Code 128, 7-33
Scanner Trigger, 7-82
Decode Priority (5020 only), 7-37
Symbology Identifier, 7-98
Decode Security, 7-40
UPC/EAN, 7-108
Interleaved 2 of 5, 7-55
Virtual Wedge, 7-112
MSI, 7-61
Virtual Wedge Code Page, 7-112
PDF 417, 7-65
Virtual Wedge Grid, 7-113
IDRS (5020 only)
IDRSEnable, 7-47
IDRSServerAddr, 7-48
IDRSRetries, 7-47
IDRSTimeout, 7-49
IDRSScope, 7-48
Internet Explorer (IE)
IE Autodial Name, 7-49
IE Proxy Server Port, 7-52
IE Cache Size, 7-50
IE Underline Links, 7-52
IE Function Key URLs, 7-50
IE Use LAN (No Auto Dial), 7-53
IE Home Page, 7-51
IE Use Proxy Server, 7-54
IE Proxy Server Address, 7-51
7-4
Page 133
Configuration Command Reference
7
Network
502X IP Address, 7-10
Secondary DNS Server, 7-83
Default Router, 7-41
Secondary WINS Server, 7-84
Device Name, 7-42
Subnet Mask, 7-96
DHCP (Obtain IP Address Via DHCP) , 7-43
TCP/IP Extensions Delayed Acknowledgement Timer, 7-103
Primary DNS Server, 7-71
TCP/IP Extensions Initial Roundtrip Time, 7-103
Primary WINS Server, 7-72
TCP/IP Extensions Receive Window Size, 7-104
OpenAir (5020 only)
Access Point MAC Address, 7-12
Radio ROM Version, 7-74
Access Point Name, 7-12
Roaming Allowed, 7-76
Domain, 7-46
Security Identification (ID) , 7-85
Inactivity Timeout, 7-54
Transmit Mode, 7-106
Radio MAC Address, 7-73
802.11b HR
Access Point Density, 7-11
Receive All Multicasts, 7-74
Access Point MAC Address, 7-12
Reservation Threshold, 7-75
Access Point Network Name, 7-13
Station Name, 7-96
Maximum Sleep Duration, 7-60
Supported WEP, 7-97
Network Name, 7-63
Transmit Rate, 7-107
Power Management, 7-69
WEP Encryption, 7-115
Primary/Station ROM Version, 7-72
WEP Key, 7-116
Radio Description, 7-73
WEP Key Length , 7-117
Radio MAC Address, 7-73
WEP Transmit Key, 7-117
7-5
Page 134
502X Data Collection PC System Manual
SNMP
Identification Contact, 7-86
Security Subnet Mask, 7-90
Identification Location, 7-86
Security Write Encryption, 7-91
Identification Name, 7-87
Trap Authentication, 7-92
Security Encryption Key, 7-87
Trap Community Name, 7-92
Security IP Address, 7-88
Trap IP Address, 7-93
Security Read Encryption, 7-89
Trap Port, 7-94
Security Read-Only Community String, 7-89
Trap Threshold, 7-94
Security Read/Write Community String, 7-90
TFTP
TFTP Resend Limit, 7-105
TFTP Timeout, 7-105
UDP Plus
Acknowledgement Delay Lower Limit, 7-13
Maximum Retries, 7-60
Acknowledgement Delay Upper Limit, 7-14
Network Loopback, 7-63
Controller Connect Check Receive Timer, 7-35
Network Port, 7-64
Controller Connect Check Send Timer, 7-36
UDP Plus Enable, 7-107
Controller IP Address, 7-37
Unit
Automatic Shutoff, 7-15
IrDA Baud Rate, 7-57
Beep Duration (5020 only), 7-16
Keypad Caps Lock, 7-58
Beep Frequency (5020 only), 7-18
Keypad Clicker, 7-59
Display Backlight Level, 7-44
Speaker Volume, 7-95
Display Backlight Timeout, 7-44
7-6
Page 135
Configuration Command Reference
7
Configuration Commands Listed by Bar Code Syntax The next table lists the configuration commands you can set by scanning bar codes with the 502X. The configuration commands are listed in alphabetic order by syntax. You can also configure these commands by using the Configuration application, the Configuration Management application in Unit Manager, or using SNMP. Syntax
Command
For Help, See Page
ADdata
Preamble
7-69
AEdata
Postamble
7-67
BVdata
Speaker Volume
7-95
BBdata
Low Beep Duration (5020 only)
7-16
BCdata
High Beep Duration (5020 only)
7-16
BGdata
Low Beep Frequency (5020 only)
7-18
BHdata
High Beep Frequency (5020 only)
7-18
CAdata
Interleaved 2 of 5 Code (I 2 of 5)
7-55
CBdata
Code 39
7-26
CCdata
Code 2 of 5 (2 of 5)
7-24
CDdata
Codabar
7-20
CEdata
UPC/EAN
7-108
CFdata
Code 93
7-32
CGdata
Code 11 (5020 only)
7-21
CHdata
Code 128
7-33
CIdata
Plessey (5020 only)
7-66
CJdata
Code 49 (5020 only)
7-30
CKdata
Code 49 Function Code 1 (5020 only)
7-30
CLdata
Code 49 Function Code 2 (5020 only)
7-30
CMdata
Code 49 Function Code 3 (5020 only)
7-30
CNdata
MSI
7-61
CPdata
Code 16K (5020 only)
7-23
CQdata
PDF 417
7-65
CSdata
Decode Security
7-40
CTdata
Decode Priority (5020 only)
7-37
CYdata
Symbology Identifier
7-98
DFdata
Display Backlight Timeout
7-44
7-7
Page 136
502X Data Collection PC System Manual
Bar Code Configuration Commands by Syntax (continued)
7-8
Syntax
Command
For Help, See Page
EZdata
Automatic Shutoff
7-15
KAdata
Keypad Caps Lock
7-58
KCdata
Keypad Clicker
7-59
SAdata
Scanner Timeout
7-81
SBdata
Scanner Mode (5020 only)
7-77
SCdata
Scanner Trigger
7-82
SRdata
Scanner Redundancy
7-78
SSdata
Scanner Selection (5020 only)
7-79
Page 137
Configuration Command Reference
7
Entering Variable Data in a Configuration Command You can enter variable data for many of the configuration commands. For example, you can set a preamble that is up to 31 ASCII characters long. Follow these general instructions to enter variable data. To enter variable data in a configuration command
1. Scan a bar code label with this syntax: +/$+command where: +/ is the syntax for the Enter Accumulate Mode command.
$+ is the syntax for the Change Configuration command.
command is the syntax and data for the command you want to change.
For example, the command syntax for a preamble is ADdata. To change or set a preamble, scan this bar code: Enter Accumulate Mode / Change Configuration / Set Preamble
*+/$+AD* *+/$+AD*
2. Scan a bar code label from the “Full ASCII Bar Code Chart” in Appendix B. If the data you enter forms a reader or configuration command such as BV for Speaker Volume, you must enclose the data in quotes. If you are entering quotation marks as data, you must enclose the data within quotation marks and precede each quotation mark with another quotation mark. For help, see “Configuring the 502X by Scanning Bar Code Labels” in Chapter 2 of your user’s manual. To set the preamble to the character T, scan this label: T
*T* *T*
Note: To use the bar code labels in Appendix B, you must configure the 502X to use Code 39 in Full ASCII mode. For help, see “Code 39” later in this chapter. 3. Scan the Exit Accumulate Mode bar code label to update the 502X’s configuration: Exit Accumulate Mode
*-/* *-/*
7-9
Page 138
502X Data Collection PC System Manual
502X IP Address Purpose:
Configuration:
Defines the IP address assigned to the 502X in your RF or Ethernet network. An IP address is a unique network level address you assign to each device in a TCP/IP network. If you are using a DHCP server, the IP address is automatically assigned. After you change this parameter, suspend and resume the 502X to make the change effective. Use one of these methods: Configuration Applications
SNMP
Bar Codes
Fast Config
Yes
Yes
No
Yes
In the Configuration or Configuration Management application, choose Configure and then Network. Next, choose either Radio or Ethernet, then IP Address, then Obtain IP Address via DHCP, and finally choose IP Address. On Cold Boot: SNMP OID:
Saved 1.3.6.1.4.1.1963.5.15.5.2.1.2.index where index is the radio or I/O adapter card number.
Options:
This address must be a valid IPv4 address that has the form y.x.x.x where y is a value between 1 and 223 (not including 127) and x is a value between 0 and 255. Default:
7-10
0.0.0.0