The text of a manual · part 32 of 33
502X Data Collection PC System Manual: Appendix D: Extending the Configuration Applications, pages 287 to 296
Pages 287 to 296 of 310, from 502X Data Collection PC System Manual
The original document is the PDF (2.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 5020
Page 287
Ng C9
Extending the Configuration Applications
D
ChoiceFmt Purpose:
Specifies a choice list in the user interface.
Syntax:
"n#<text>¦n1#<text>¦…" where n, n1, and so on is the numeric value and <text> is the corresponding textual description of n, n1, and so on.
Type: Example:
Integer The ChoiceFmt definition for Beep (or Beeper) Volume is: [HKEY_LOCAL_MACHINE\SOFTWARE\Intermec\RUM\CONFIGAPP\CHILDREN\UNIT\ CHILDREN\SPEAKER\PROPERTIES\itcBeeperVolume] "DisplayName"="Volume" "OID"="1.3.6.1.4.1.1963.15.3.1.3.0" "Type"="Integer" "DefVal"="3" "Ordinal"="1" "ChoiceFmt"="0#Off¦1#Very quiet¦2#Quiet¦3#Normal¦4#Loud¦5#Very loud"
CmdOID Purpose:
Used by subitems of reader or configuration commands to indicate the parent’s OID. The value you enter is the OID of the item of which this is a parameter (parent’s OID). The CmdOID is designed for reader and configuration commands. You can also use CmdOID for any item that is a string where you want to edit substrings independently. For help with commands, see Chapter 6, “Reader Command Reference,” or Chapter 7, “Configuration Command Reference.”
Syntax:
"n:y" where n is the parent OID and y is the position.
Type:
Integer
See also:
CmdString, OID, reader and configuration commands
Example:
The CmdOID for the third digit of Code 39 is: "CmdOID"= "1.3.6.1.4.1.1963.15.3.3.1.1.3.1:3"
Code 39 is a parent and has its own OID. However, you can set three options for Code 39 and each option or digit has a CmdOID. The third digit is where you select non-full ASCII, full ASCII, or mixed-full ASCII Code 39. For help, see “Code 39” in Chapter 7. [HKEY_LOCAL_MACHINE\SOFTWARE\Intermec\RUM\CONFIGAPP\CHILDREN\ DATACOLLECTION\CHILDREN\SYMBOLOGIES\PROPERTIES\itcCode39\PROPERTIES\3] "DisplayName"="ASCII" "Type"="Integer" "DefVal"="1" "Ordinal"="3" "CmdOID"="1.3.6.1.4.1.1963.15.3.3.1.1.3.1:3" "ChoiceFmt"="0#Non-full ASCII|1#Full ASCII|2#Mixed full ASCII"
D-11
Page 288
502X Data Collection PC System Manual
Nugg Code39
CmdString Purpose:
Specifies the number and widths of the subitems for a reader or configuration command. This entry is required for properties where the type is ReaderCmd.
Syntax:
"n,w1,w2…wn" where n is the number of options, w1 is the field width of the first option, w2 is the field width of the second option, and so on to wn.
Type:
ReaderCmd
See also:
CmdOID, reader and configuration commands
Example:
Code 39 has three options or digits, so the CmdString is: "CmdString"= "3,1,1,1" The “3” defines the three options and each option is a single digit. For help, see “Code 39” in Chapter 7. [HKEY_LOCAL_MACHINE\SOFTWARE\Intermec\RUM\CONFIGAPP\CHILDREN\ DATACOLLECTION\CHILDREN\SYMBOLOGIES\PROPERTIES\itcCode39] "OID"="1.3.6.1.4.1.1963.15.3.3.1.1.3.1" "DisplayName"="Code 39" "Type"="ReaderCmd" "Ordinal"="1" "CmdString"="3,1,1,1" "DefVal"="101" "ShortDesc"="If Code 39 Options equals HIBC, then Check digit must equal Retain and ASCII must equal Non-full ASCII"
Constraint
D-12
Purpose:
Reserved for future use.
Syntax:
Reserved
Type:
Reserved
Page 289
Ng C9
Extending the Configuration Applications
D
DefVal Purpose:
The Intermec factory default value for this configuration item. You do not set DefVal for ReadOnly items.
Syntax:
"string" where "string" is the default value in quotes.
Type: Example:
All The DefVal for Beeper Volume is “3”, where 3 is a normal beep volume. [HKEY_LOCAL_MACHINE\SOFTWARE\Intermec\RUM\CONFIGAPP\CHILDREN\UNIT\ CHILDREN\SPEAKER\PROPERTIES\itcBeeperVolume] "DisplayName"="Volume" "OID"="1.3.6.1.4.1.1963.15.3.1.3.0" "Type"="Integer" "DefVal"="3" "Ordinal"="1" "ChoiceFmt"="0#Off¦1#Very quiet¦2#Quiet¦3#Normal¦4#Loud¦5#Very loud"
DisplayName Purpose:
Text that displays on the user interface (menu, label, or caption).
Syntax:
"string" where "string" is a text string in quotes.
Type: Example:
All Here is the DisplayName for the Scanner configuration tab or page and for one of the parameters, Scanner Timeout. [HKEY_LOCAL_MACHINE\SOFTWARE\Intermec\RUM\CONFIGAPP\CHILDREN\ DATACOLLECTION\CHILDREN\SCANNER] "DisplayName"="Scanner" [HKEY_LOCAL_MACHINE\SOFTWARE\Intermec\RUM\CONFIGAPP\CHILDREN\ DATACOLLECTION\CHILDREN\SCANNER\PROPERTIES\itcScannerTimeout] "OID"="1.3.6.1.4.1.1963.15.3.3.3.1.1.5.1.1" "DisplayName"="Timeout" "Type"="Integer" "DefVal"="0" "Ordinal"="1" "Range"="0,60"
D-13
Page 290
502X Data Collection PC System Manual
Nugg Code39
Expert Purpose:
Reserved for future use.
Syntax:
Reserved
Type:
Reserved
Hidden Purpose:
Reserved for future use.
Syntax:
Reserved
Type:
Reserved
MaxChars Purpose:
Specifies the maximum number of characters that can be entered in the user interface.
Syntax:
"n" where n is any positive integer.
Type:
Octet string
See also:
TextFmt
Example:
The MaxChars for preamble is 31 characters. [HKEY_LOCAL_MACHINE\SOFTWARE\Intermec\RUM\CONFIGAPP\CHILDREN\ DATACOLLECTION\CHILDREN\VIRTUALWEDGE\PROPERTIES\itcRVWPreAmble] "OID"="1.3.6.1.4.1.1963.15.3.2.1.1.3.1" "DisplayName"="Preamble" "Type"="Octet String" "DefVal"="" "Ordinal"="2" "MaxChars"="31"
D-14
Page 291
Ng C9
Extending the Configuration Applications
D
OID Purpose:
SNMP Object Identifier (OID) for the configuration item.
Syntax:
"n.n.n.n…" where n is an OID.
Type:
All
See also:
CmdOID
Example:
The OID for preamble is 1.3.6.1.4.1.1963.15.3.2.1.1.3.1. [HKEY_LOCAL_MACHINE\SOFTWARE\Intermec\RUM\CONFIGAPP\CHILDREN\ DATACOLLECTION\CHILDREN\VIRTUALWEDGE\PROPERTIES\itcRVWPreAmble] "OID"="1.3.6.1.4.1.1963.15.3.2.1.1.3.1" "DisplayName"="Preamble" "Type"="Octet String" "DefVal"="" "Ordinal"="2" "MaxChars"="31"
Ordinal Purpose:
Specifies the order of the item relative to its siblings or properties at the same level. The ordinal also indicates the order in each sublevel.
Syntax:
"n"
Type: Example:
Not applicable. In the Scanner page, Scanner Timeout is the first property or parameter, so it has an ordinal value of “1.” Scanner Mode is the second property or parameter, so the ordinal value is “2.” [HKEY_LOCAL_MACHINE\SOFTWARE\Intermec\RUM\CONFIGAPP\CHILDREN\ DATACOLLECTION\CHILDREN\SCANNER\PROPERTIES\itcScannerTimeout] "OID"="1.3.6.1.4.1.1963.15.3.3.3.1.1.5.1.1" "DisplayName"="Timeout" "Type"="Integer" "DefVal"="0" "Ordinal"="1" "Range"="0,60" [HKEY_LOCAL_MACHINE\SOFTWARE\Intermec\RUM\CONFIGAPP\CHILDREN\ DATACOLLECTION\CHILDREN\SCANNER\PROPERTIES\itcScannerMode] "OID"="1.3.6.1.4.1.1963.15.3.3.3.1.1.6.1.1" "DisplayName"="Mode" "Type"="Integer" "DefVal"="0" "Ordinal"="2" "ChoiceFmt"="0#One shot|1#Auto-trigger"
D-15
Page 292
502X Data Collection PC System Manual
Nugg Code39
PageDependency Purpose:
Reserved for use by Intermec.
Syntax:
Reserved
Type:
Reserved
Example:
Reserved for use by Intermec as shown next. [HKEY_LOCAL_MACHINE\SOFTWARE\Intermec\RUM\CONFIGAPP\CHILDREN\ DATACOLLECTION\CHILDREN\SYMBOLOGIES] "PageDependency"="PageDependency.PageDependency.1" "DisplayName"="Symbologies"
PropEditor Purpose:
Reserved for future use.
Syntax:
Reserved
Type:
Reserved
Range Purpose:
Specifies the range of allowed values.
Syntax:
"n,m" where n is the lower limit of the range and m is the upper limit.
Type: Example:
Integer The range for Scanner Timeout is any number from 0 to 60. [HKEY_LOCAL_MACHINE\SOFTWARE\Intermec\RUM\CONFIGAPP\CHILDREN\ DATACOLLECTION\CHILDREN\SCANNER\PROPERTIES\itcScannerTimeout] "OID"="1.3.6.1.4.1.1963.15.3.3.3.1.1.5.1.1" "DisplayName"="Timeout" "Type"="Integer" "DefVal"="0" "Ordinal"="1" "Range"="0,60"
D-16
Page 293
Ng C9
Extending the Configuration Applications
D
ReadOnly Purpose:
Specifies a read-only configuration item.
Syntax:
"True"
Type: Example:
Not applicable. The Access Point Name is a read-only configuration item since the information is supplied from the access point. [HKEY_LOCAL_MACHINE\SOFTWARE\Intermec\RUM\CONFIGAPP\CHILDREN\Network\ CHILDREN\OpenAir1\PROPERTIES\OpenAirConfig\PROPERTIES\itcOpenAir ConnectedAP.2] "OID"="1.3.6.1.4.1.1963.5.5.2.5.1.1.1.?" "Adapter"="OpenAir" "Type"="Octet String" "Ordinal"="1" "DisplayName"="Access Pt Name" "ShortDesc"="The next time the adapter is used it will have the new settings. If the adapter is currently in the device you can suspend and then resume the device to have the changes take effect." "MaxChars"="255" "ReadOnly"="True"
Security Purpose:
Reserved for future use.
Syntax:
Reserved
Type:
Reserved
ShortDesc Purpose:
When you edit a configuration item in the Configuration Management application, this text displays below the options for the configuration item. The short description does not display on the 502X Configuration application.
Syntax:
"string" where "string" is a text string in quotes.
Type:
All
D-17
Page 294
502X Data Collection PC System Manual
Nugg Code39
ShortDesc (continued)
Example:
Here is the short description for Code 2 of 5. [HKEY_LOCAL_MACHINE\SOFTWARE\Intermec\RUM\CONFIGAPP\CHILDREN\DATACOLLECT ION\CHILDREN\SYMBOLOGIES\PROPERTIES\itc2of5] "OID"="1.3.6.1.4.1.1963.15.3.3.1.1.4.1" "DisplayName"="Code 2 of 5" "Type"="ReaderCmd" "Ordinal"="3" "CmdString"="2,1,2" "DefVal"="000" "ShortDesc"="If Code 2 of 5 is enabled, Interleaved 2 of 5 will be disabled."
TextFmt Purpose:
Specifies the formatting for a string of characters that you can enter in the user interface. You specify the maximum length of the string by the number of formatting characters (# or &).
Syntax:
"#" or "&" where: # &
Allows only a numeric character between 0 and 9. Allows any ASCII character.
You can only use one type of formatting character (# or &) in a string. Type:
Octet string
See also:
MaxChars
Example:
In the Decode Priority command, TextFmt defines a numeric-only field that is 24 digits long. [HKEY_LOCAL_MACHINE\SOFTWARE\Intermec\RUM\CONFIGAPP\CHILDREN\DATACOLLECT ION\CHILDREN\DECODEOPTIONS\PROPERTIES\itcSymPriority] "OID"="1.3.6.1.4.1.1963.15.3.3.2.1.3.1" "DisplayName"="Decode priority" "Type"="Octet String" "DefVal"="010203040506070809101112" "Ordinal"="2" "TextFmt"="########################"
D-18
Page 295
Ng C9
Extending the Configuration Applications
D
Type Purpose:
SNMP data type. Each property has a type.
Syntax:
"Integer" or "Octet String" or "ReaderCmd" or "IP Address" where ReaderCmd is a reader or configuration command. For help, see Chapter 6, “Reader Command Reference,” or Chapter 7, “Configuration Command Reference.”
Type: Example:
Not applicable. The type for preamble is an octet string. [HKEY_LOCAL_MACHINE\SOFTWARE\Intermec\RUM\CONFIGAPP\CHILDREN\ DATACOLLECTION\CHILDREN\VIRTUALWEDGE\PROPERTIES\itcRVWPreAmble] "OID"="1.3.6.1.4.1.1963.15.3.2.1.1.3.1" "DisplayName"="Preamble" "Type"="Octet String" "DefVal"="" "Ordinal"="2" "MaxChars"="31"
Required and Optional Registry Property Values This table indicates, for each level in the registry, whether the value is required, optional, or not applicable (N/A). Every property (label or non-label) MUST have the following: •
DisplayName
•
Ordinal
All non-label properties MUST have the following: •
DisplayName
•
Ordinal
•
Type
•
DefVal
•
OID or CmdOID
D-19
Page 296
502X Data Collection PC System Manual
Nugg Code39
Required and Optional Registry Property Values
Registry Property Value
Root
MenuItem
PageView
Properties
Adapter
N/A
N/A
Optional
N/A
Bound
N/A
N/A
N/A
Optional
ChoiceFmt
N/A
N/A
N/A
Optional
CmdOID
N/A
N/A
N/A
Required for ReaderCmd subitems
CmdString
N/A
N/A
N/A
Required for ReaderCmd
Constraint
N/A
N/A
N/A
Optional
DefVal
N/A
N/A
N/A
Required if non-label
DisplayName
N/A
Required
Required
Required
Expert
N/A
Optional
Optional
Optional
Hidden
N/A
Optional
Optional
Optional
MaxChars
N/A
N/A
N/A
Optional
OID
N/A
N/A
N/A
Required if non-label
Ordinal
N/A
N/A
N/A
Required
PageDependency
N/A
N/A
Optional
N/A
PropEditor
N/A
N/A
N/A
Optional
Range
N/A
N/A
N/A
Optional
ReadOnly
N/A
N/A
N/A
Optional
Security
N/A
Optional
Optional
Options
ShortDesc
N/A
N/A
N/A
Optional
TextFmt
N/A
N/A
N/A
Optional
Type
N/A
N/A
N/A
Required if non-label
[CHILDREN]
Required
Required
N/A
N/A
[PROPERTIES]
N/A
N/A
Required
Optional
D-20