The text of a manual · part 8 of 33
502X Data Collection PC System Manual: Chapter 4: Using Unit Manager, pages 57 to 65
Pages 57 to 65 of 310, from 502X Data Collection PC System Manual
The original document is the PDF (2.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 5020
Page 57
4 Using Unit Manager
Page 58
lkj;kj;kj;lkj;lj
Page 59
Using Unit Manager
4
This chapter explains how you can use the Unit Manager applications to configure parameters and manage files, processes, applications, and security on your 502X - all from your desktop PC.
Using the Unit Manager Applications Unit Manager (Unit Management on 5023) for PlanNET provides a suite of applications you can use to remotely manage 502Xs. To access Unit Manager on your desktop PC, you need to connect the 502X to an Ethernet or RF network. The Unit Manager applications include Configuration Management
Use this application to change configuration parameters and view system information. Perform a variety of file and directory functions including copying, creating, deleting, and uploading. File Manager
Process Manager
View lists of active processes and process information.
Application Manager
Install and uninstall applications.
View lists of system software-generated events, which can be helpful when troubleshooting applications. Event Viewer
Password
Enable and manage password security on your 502X.
The following sections explain how to use each Unit Manager application. Note: Unit Manager for PlanNET works best with Internet Explorer 4.0 or higher on Windows 95/98/NT/2000. Netscape Navigator 4.0 or higher is also supported on Windows 95/98/NT/2000. Unit Manager will work on other platforms such as Unix or Macintosh using Netscape Navigator 4.0 or higher, but the installation process and performance of the Java plug-in varies by platform. You may experience some limitations due to browser implementation issues. For help with the Java plug-in on other platforms, see the Sun Microsystems Web page at www.java.sun.com/products/plugin. You can also extend and customize the Unit Manager main menu. For help, see Appendix C, “Extending the Unit Manager Main Menu.” To connect to the 502X from your desktop PC
'
1. Use the D5020 dock or the L5020 adapter to connect the 502X to AC power. 2. Press to turn on the 502X. If you have enabled the “suspend while on external power” feature in the Power applet, scan this bar code label to turn off the Automatic Shutoff feature:
Disable Automatic Shutoff
*$+EZ0* *$+EZ0*
4-3
Page 60
502X Data Collection PC System Manual
Note: The 502X must be turned on and must remain on while you manage it through Unit Manager. If you have an RF 502X, it must be in range of an access point. 3. Configure the 502X to communicate with your RF or Ethernet network. For help, see “Setting the Network Parameters” in Chapter 3 of your user’s manual. 4. If your desktop PC is running Windows 98, Windows NT, or Windows 2000, turn off the Active Desktop if you have it enabled. If your desktop PC is running Windows 95, continue with Step 5. 5. On your desktop PC, launch version 4.0 or higher of Internet Explorer or Netscape Navigator. 6. If you access the Internet by using a proxy server, add the IP address for each 502X you want to manage to the proxy server exceptions list. 7. In the browser Address or Location field, type the IP address of the 502X that you want to configure, and then press Enter: x.x.x.x where x.x.x.x is the IP address of the 502X. The Unit Manager login screen appears on your desktop PC.
8. If security is enabled on the 502X, type the password and then click Submit. If security is not enabled, click Submit. The Unit Manager main menu appears.
9. Click the name of the Unit Manager application that you want to use. Note: On the 5023, the login and main menu screens show the name “Unit Management.”
4-4
Page 61
Using Unit Manager
4
Using Configuration Management Configuration Management is a remote version of the Configuration application on the 502X. You can use Configuration Management to • view, change, or set all 502X parameters in real time.
• restore factory defaults to all parameters in a parameter list.
• view system and terminal information.
To use Configuration Management, you need the Java 1.3 plug-in. You can automatically download the plug-in during the next procedure. To run Configuration Management
1. Connect to the 502X using a Web browser and start Unit Manager. For help, see “To connect to the 502X from your desktop PC” earlier in this chapter. 2. Click Configuration. The Intermec Configuration Management screen appears.
Note: If the Java 1.3 plug-in is not installed on your PC, it automatically downloads now from the Sun Microsystems Web site. If you choose to download the plug-in from the developer’s kit, follow the instructions to install it.
4-5
Page 62
502X Data Collection PC System Manual
The Configuration Management screen includes two options: Click on the icons to view data collection, unit, Internet Explorer (IE) browser, network, and SNMP parameters. You can configure the same parameters using Configuration Management as you do using the Configuration application on the 502X. Configure
Choose this option to check the battery status and view 502X version information. You can check the battery status for the main battery pack and the bridge battery. Troubleshoot
Note: Do not resize or refresh the Intermec Configuration Management windows until the Web page is completely loaded. If you do resize the window, wait for the Web page to refresh and finish loading before you resize or refresh again. To view and set parameters using Configuration Management
1. Connect to the 502X using a Web browser and start Unit Manager. For help, see “To connect to the 502X from your desktop PC” earlier in this chapter. 2. Click Configuration. The Intermec Configuration Management screen appears. 3. Click the folder icon for the parameter group you want to configure. The configuration screen for that group appears. For example, click Unit and the Unit configuration screen appears.
See the next illustration to see how the parameters are listed in each of the five groups. Note: The illustration shows the first level of parameters in each group. To find a parameter not shown in the illustration, see the command name in Chapter 7.
4-6
Page 63
Using Unit Manager
4
Configuration Management Parameter Groups
Data Collection
Scanner
Timeout Mode Trigger Mode* Redundancy Selection*
Decode Options
Decode Security Level Decode Priority*
Virtual Wedge
Virtual Wedge Preamble Postamble Grid Code Page
Symbologies
Code 39 Interleaved 2 of 5 Code 2 of 5 Codabar Code 93/93i Code 11* Code 49* MSI Code 16K* UPC/EAN Plessey* Code 128 PDF 417
Symbology ID*
Code 39 ID Code 128 ID Codabar ID Code 93 ID Code 11 ID Interleaved 2 of 5 ID Code 16K ID PDF 417 ID MSI ID Plessey ID Straight 2 of 5 (2 bar SS) ID Straight 2 of 5 (3 bar SS) ID Code 49 ID Code 49 Function Code 1 ID Code 49 Function Code 2 ID Code 49 Function Code 3 ID UPC A ID UPC E ID EAN 8 ID EAN 13 ID
* 5020 only
Unit
IE Browser
Date/Time
Date and Time
Display
Backlight Timeout Backlight Level
Keypad
Key Clicks Caps Lock On
Power Management
Automatic Shutoff
Serial Port
IrDA Baud Rate
Speaker
Volume Low Beep Frequency* High Beep Frequency* Low Beep Duration* High Beep Duration*
Options
Radio or Ethernet
(Batch 5020s only)
F6 key F7 key F8 key F9 key F10 key
Function Key URLs
SNMP
Network Protocols
Home Page Cache Size (KB) Underline Links Use LAN (no auto dial) Use Proxy Server
UDP Plus TFTP IDRS*
Security
IP Address Name Servers TCP/IP Extensions Radio
Read Only Community String Read/Write Community String Read Encryption Write Encryption Encryption Key
Traps
Authentication Threshold
Identification
Contact Name Location
IP Address Name Servers
Advanced
Config Manager Enable Config Subagent Enable UDP Plus Enable
Identification
Device Name 502XS301.eps
Note: Some parameters are available only on the 5020 and are marked with an asterisk (*) in the illustration.
4-7
Page 64
502X Data Collection PC System Manual
4. Click the tab for the parameter you want to change. 5. Click the parameter you want to change. You may need to click to expand a parameter list. The parameter options appear in the lower part of the screen. 6. Change the parameter by • clicking an option or check box.
• selecting a new value from a drop-down list.
• typing the new value in the entry field.
You can also click Default to restore the factory default values to all parameters in the list. 7. Do one of the following: •
Click Apply to save your changes.
•
Click Refresh to restore the previous values and discard unapplied changes.
8. To exit the Configuration Management screen, click another option from the Unit Manager menu or exit your Web browser. 9. If you changed any network settings, press changes take effect.
' twice on the 502X to have the
Note: If you changed the UDP Plus Enable parameter, warm boot the 502X. For help, see “Booting the 502X” in Chapter 4 of your user’s manual.
Printing a Configuration Management Screen You can print any Configuration Management screen for a hard copy of a 502X’s configured settings. To print a Configuration Management screen
1. Press Alt-PrintScreen to capture the screen you wish to print. 2. Paste the screen capture into a document. 3. Print the document. Note: Using the Print command in the browser File menu may cause some browsers to lock up.
4-8
Page 65
Using Unit Manager
4
To view unit information
1. Connect to the 502X using a Web browser and start Unit Manager. For help, see “To connect to the 502X from your desktop PC” earlier in this chapter. 2. Click Configuration. The Intermec Configuration Management screen appears. 3. Click Troubleshoot and then click Unit Information. The Unit Information screen appears with the Battery Status tab active.
The Battery Status tab shows the condition and charge levels of the main battery pack and bridge battery. 4. To view Terminal Version information, click the Terminal Version tab. The tab shows the 5020’s last service date, model number, serial number, manufacturing software version, current software version, current software build, and PCB part number. 5. To exit, click another option from the Unit Manager menu or exit your Web browser.
4-9