Manual · Microscan
EZ Match Imager User Manual
Manual431 pagesPDF 3.5 MB
User manual for the Microscan EZ Match Imager, covering setup, ESP software, tube/cap inspection, communications and symbologies.
Covers · 1 model
The models it covers
Summary
What is in it
The complete user manual for the Microscan EZ Match Imager, a fixed imager that detects tube and cap types and decodes linear and 2D symbols. It walks through a quick start, the Windows-based ESP (Easy Setup Program), tube/cap inspection, host and auxiliary port communications, calibration, read cycle and trigger settings, symbologies, I/O parameters, symbol quality, matchcode, camera and IP setup, the IP database, utilities and output formatting, with specifications in the appendices.
Its parts
- Quick Start
- Using ESP
- Tube/Cap Inspection
- Communications
- Calibration
- Read Cycle
- Symbologies
- I/O Parameters
- Symbol Quality
- Matchcode
- Camera and IP Setup
- IP Database
- Terminal
- Utilities
- Output Format
From the manual
Key facts from this manual
Each line names its page in the PDF.
User manual for the Microscan EZ Match Imager, which identifies sample tube and cap types and reads linear and 2D symbols; it covers the monochrome EZ Match and the EZ Match Color. It explains connecting and positioning the imager, setup and calibration with the ESP software or the EZ Button, host communications, I/O wiring and the specifications.
- Device
- Imager that identifies tube and cap types, learns new ones, and reads linear and 2D symbols p. 8
- Sensor
- EZ Match Color: 3 megapixel, 2048 x 832; EZ Match: 1.3 megapixel monochrome, 1280 x 1024 p. 8, 372
- Interfaces
- USB, RS-232 and RS-422/485 p. 8
- Connector
- 3 ft cable ending in a high density 15-pin D-Sub socket or a USB type A connector p. 372
- Power
- 5VDC +/- 5%, 3.5 W max, 440 mA typical; 10-28V with an optional accessory p. 375
- Discrete I/O
- Trigger and New Master inputs rated 5 to 28VDC; Outputs 1, 2, 3 are 5V TTL, sink and source 10 mA; optoisolated with the IC-332 accessory p. 372
- Host baud rates
- 600 to 230K baud on the RS-232, RS-422 or RS-485 host port p. 72
- Symbologies
- Data Matrix (ECC 0-200), QR Code, PDF417, MicroPDF417, GS1 DataBar, Code 39, Code 128, BC412, Interleaved 2 of 5, Pharmacode, UPC/EAN, Codabar, Code 93 p. 372
- Read parameters
- Pitch ±30°, skew ±30°, tilt 360°; up to 10 decodes per second p. 372
- Working distance
- Focal distance 2 to 6 inches from the tube, cap or symbol p. 16
- Lighting and indicators
- High-output white LEDs, blue target pattern, green good-read flash, beeper p. 372
- Size and weight
- 1 x 1.8 x 2.10 in (25.4 x 45.7 x 53.3 mm), 2 oz (57 g) p. 372
- Environment
- 0 to 50°C operating, -50 to 75°C storage, up to 90% humidity non-condensing, IP54 enclosure p. 372
- Setup software
- ESP (Easy Setup Program) for Windows Vista, XP or 2000, on the Microscan Tools CD p. 17
What this manual walks you through
- Connecting the imager, interface box, sensor and power by RS-232, RS-422 or RS-485 p. 15
- Positioning the imager and background for tube, cap and symbol inspection p. 16
- Installing the ESP software p. 17
- Connecting to the imager in ESP p. 19, 20
- Aiming with the blue target pattern from ESP or the EZ Button p. 21, 22
- Calibrating by EZ Button, ESP or serial command p. 23
- Testing the read rate p. 24
- Changing and saving settings in ESP p. 25, 26
- Wiring optoisolated outputs and inputs and an external trigger p. 375, 376, 377, 396
- Installing the USB-to-Serial Virtual COM Port Driver p. 398
Good to know
- Connect all cables before applying power, and power down before disconnecting any cable. p. 15
- A USB model must be connected to the host computer before it is powered on, or it is not recognized. p. 15
- Clean the hard coated window only with 100% isopropyl alcohol. p. 397
- Do not insulate the stand mount; the bottom panel needs metal-to-metal contact to shed heat. p. 397
- No more than 100mA may pass through the output optoisolator. p. 376
Questions this manual answers
What power supply does the Microscan EZ Match need?
5VDC +/- 5%, drawing 3.5 W at most and about 440 mA typical; a 10-28V supply can be used with an optional accessory. p. 375
How do I reset the EZ Match to its default configuration by wiring?
Connect pin 8 of the 15-pin host connector to ground pin 4. p. 375
How far from the tube should the EZ Match be mounted?
At a focal distance of 2 to 6 inches, with skew and pitch no more than ±30°. p. 16
How do I calibrate the EZ Match?
Hold the EZ Button about two seconds until two short beeps, click Calibrate in ESP, or send <@CAL> from a terminal program. p. 23
Why is my USB EZ Match not recognized by the computer?
A USB model must be connected to the host computer before it is powered on. p. 15
Contents
Chapters and sections
Each line opens the PDF at its page.
- EZ Match User Manual1
- About the EZ Match Imager8
- About This Manual8
- Highlighting8
- Host Communications8
- Warning and Caution Summary9
- Statement of Agency Compliance10
- Statement of RoHS Compliance11
- 1 Quick Start13
- 2 Using ESP27
- 3 Tube/Cap Inspection45
- 4 Communications69
- 5 Calibration105
- 6 Read Cycle123
- 7 Symbologies151
- 8 I/O Parameters185
- 9 Symbol Quality245
- 10 Matchcode259
- 11 Camera and IP Setup271
- 12 IP Database307
- 13 Terminal325
- 14 Utilities331
- 15 Output Format357
- Appendices371
- Index407
The whole text · 44 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 101-10
- Pages 11 to 2011-20
- Pages 21 to 3021-30
- Pages 31 to 4031-40
- Pages 41 to 5041-50
- Pages 51 to 6051-60
- Pages 61 to 7061-70
- Pages 71 to 8071-80
- Pages 81 to 9081-90
- Pages 91 to 10091-100
- Pages 101 to 110101-110
- Pages 111 to 120111-120
- Pages 121 to 130121-130
- Pages 131 to 140131-140
- Pages 141 to 150141-150
- Pages 151 to 160151-160
- Pages 161 to 170161-170
- Pages 171 to 180171-180
- Pages 181 to 190181-190
- Pages 191 to 200191-200
- Pages 201 to 210201-210
- Pages 211 to 220211-220
- Pages 221 to 230221-230
- Pages 231 to 240231-240
- Pages 241 to 250241-250
- Pages 251 to 260251-260
- Pages 261 to 270261-270
- Pages 271 to 280271-280
- Pages 281 to 290281-290
- Pages 291 to 300291-300
- Pages 301 to 310301-310
- Pages 311 to 320311-320
- Pages 321 to 330321-330
- Pages 331 to 340331-340
- Pages 341 to 350341-350
- Pages 351 to 360351-360
- Pages 361 to 370361-370
- Pages 371 to 380371-380
- Pages 381 to 390381-390
- Pages 391 to 400391-400
- Pages 401 to 410401-410
- Pages 411 to 420411-420
- Pages 421 to 430421-430
- Page 431431
The file