Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact
Page 1 of EZ Match Imager User Manual

Manual · Microscan

EZ Match Imager User Manual

Manual431 pagesPDF 3.5 MB

User manual for the Microscan EZ Match Imager, covering setup, ESP software, tube/cap inspection, communications and symbologies.

Download the PDF3.5 MB

Covers · 1 model

The models it covers

Summary

What is in it

The complete user manual for the Microscan EZ Match Imager, a fixed imager that detects tube and cap types and decodes linear and 2D symbols. It walks through a quick start, the Windows-based ESP (Easy Setup Program), tube/cap inspection, host and auxiliary port communications, calibration, read cycle and trigger settings, symbologies, I/O parameters, symbol quality, matchcode, camera and IP setup, the IP database, utilities and output formatting, with specifications in the appendices.

Its parts

  1. Quick Start
  2. Using ESP
  3. Tube/Cap Inspection
  4. Communications
  5. Calibration
  6. Read Cycle
  7. Symbologies
  8. I/O Parameters
  9. Symbol Quality
  10. Matchcode
  11. Camera and IP Setup
  12. IP Database
  13. Terminal
  14. Utilities
  15. Output Format

From the manual

Key facts from this manual

Each line names its page in the PDF.

User manual for the Microscan EZ Match Imager, which identifies sample tube and cap types and reads linear and 2D symbols; it covers the monochrome EZ Match and the EZ Match Color. It explains connecting and positioning the imager, setup and calibration with the ESP software or the EZ Button, host communications, I/O wiring and the specifications.

Read for this summary: pages 2, 8 to 9, 13 to 26, 45, 69, 72, 372 to 377 and 396 to 398 of 431.

Device
Imager that identifies tube and cap types, learns new ones, and reads linear and 2D symbols p. 8
Sensor
EZ Match Color: 3 megapixel, 2048 x 832; EZ Match: 1.3 megapixel monochrome, 1280 x 1024 p. 8, 372
Interfaces
USB, RS-232 and RS-422/485 p. 8
Connector
3 ft cable ending in a high density 15-pin D-Sub socket or a USB type A connector p. 372
Power
5VDC +/- 5%, 3.5 W max, 440 mA typical; 10-28V with an optional accessory p. 375
Discrete I/O
Trigger and New Master inputs rated 5 to 28VDC; Outputs 1, 2, 3 are 5V TTL, sink and source 10 mA; optoisolated with the IC-332 accessory p. 372
Host baud rates
600 to 230K baud on the RS-232, RS-422 or RS-485 host port p. 72
Symbologies
Data Matrix (ECC 0-200), QR Code, PDF417, MicroPDF417, GS1 DataBar, Code 39, Code 128, BC412, Interleaved 2 of 5, Pharmacode, UPC/EAN, Codabar, Code 93 p. 372
Read parameters
Pitch ±30°, skew ±30°, tilt 360°; up to 10 decodes per second p. 372
Working distance
Focal distance 2 to 6 inches from the tube, cap or symbol p. 16
Lighting and indicators
High-output white LEDs, blue target pattern, green good-read flash, beeper p. 372
Size and weight
1 x 1.8 x 2.10 in (25.4 x 45.7 x 53.3 mm), 2 oz (57 g) p. 372
Environment
0 to 50°C operating, -50 to 75°C storage, up to 90% humidity non-condensing, IP54 enclosure p. 372
Setup software
ESP (Easy Setup Program) for Windows Vista, XP or 2000, on the Microscan Tools CD p. 17

What this manual walks you through

  • Connecting the imager, interface box, sensor and power by RS-232, RS-422 or RS-485 p. 15
  • Positioning the imager and background for tube, cap and symbol inspection p. 16
  • Installing the ESP software p. 17
  • Connecting to the imager in ESP p. 19, 20
  • Aiming with the blue target pattern from ESP or the EZ Button p. 21, 22
  • Calibrating by EZ Button, ESP or serial command p. 23
  • Testing the read rate p. 24
  • Changing and saving settings in ESP p. 25, 26
  • Wiring optoisolated outputs and inputs and an external trigger p. 375, 376, 377, 396
  • Installing the USB-to-Serial Virtual COM Port Driver p. 398

Good to know

  • Connect all cables before applying power, and power down before disconnecting any cable. p. 15
  • A USB model must be connected to the host computer before it is powered on, or it is not recognized. p. 15
  • Clean the hard coated window only with 100% isopropyl alcohol. p. 397
  • Do not insulate the stand mount; the bottom panel needs metal-to-metal contact to shed heat. p. 397
  • No more than 100mA may pass through the output optoisolator. p. 376

Questions this manual answers

What power supply does the Microscan EZ Match need?

5VDC +/- 5%, drawing 3.5 W at most and about 440 mA typical; a 10-28V supply can be used with an optional accessory. p. 375

How do I reset the EZ Match to its default configuration by wiring?

Connect pin 8 of the 15-pin host connector to ground pin 4. p. 375

How far from the tube should the EZ Match be mounted?

At a focal distance of 2 to 6 inches, with skew and pitch no more than ±30°. p. 16

How do I calibrate the EZ Match?

Hold the EZ Button about two seconds until two short beeps, click Calibrate in ESP, or send <@CAL> from a terminal program. p. 23

Why is my USB EZ Match not recognized by the computer?

A USB model must be connected to the host computer before it is powered on. p. 15

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. EZ Match User Manual1
    1. About the EZ Match Imager8
    2. About This Manual8
    3. Highlighting8
    4. Host Communications8
    5. Warning and Caution Summary9
    6. Statement of Agency Compliance10
    7. Statement of RoHS Compliance11
    8. 1 Quick Start13
    9. 2 Using ESP27
    10. 3 Tube/Cap Inspection45
    11. 4 Communications69
    12. 5 Calibration105
    13. 6 Read Cycle123
    14. 7 Symbologies151
    15. 8 I/O Parameters185
    16. 9 Symbol Quality245
    17. 10 Matchcode259
    18. 11 Camera and IP Setup271
    19. 12 IP Database307
    20. 13 Terminal325
    21. 14 Utilities331
    22. 15 Output Format357
    23. Appendices371
    24. Index407

From the PDF’s own bookmarks.

The whole text · 44 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 101-10
  2. Pages 11 to 2011-20
  3. Pages 21 to 3021-30
  4. Pages 31 to 4031-40
  5. Pages 41 to 5041-50
  6. Pages 51 to 6051-60
  7. Pages 61 to 7061-70
  8. Pages 71 to 8071-80
  9. Pages 81 to 9081-90
  10. Pages 91 to 10091-100
  11. Pages 101 to 110101-110
  12. Pages 111 to 120111-120
  13. Pages 121 to 130121-130
  14. Pages 131 to 140131-140
  15. Pages 141 to 150141-150
  16. Pages 151 to 160151-160
  17. Pages 161 to 170161-170
  18. Pages 171 to 180171-180
  19. Pages 181 to 190181-190
  20. Pages 191 to 200191-200
  21. Pages 201 to 210201-210
  22. Pages 211 to 220211-220
  23. Pages 221 to 230221-230
  24. Pages 231 to 240231-240
  25. Pages 241 to 250241-250
  26. Pages 251 to 260251-260
  27. Pages 261 to 270261-270
  28. Pages 271 to 280271-280
  29. Pages 281 to 290281-290
  30. Pages 291 to 300291-300
  31. Pages 301 to 310301-310
  32. Pages 311 to 320311-320
  33. Pages 321 to 330321-330
  34. Pages 331 to 340331-340
  35. Pages 341 to 350341-350
  36. Pages 351 to 360351-360
  37. Pages 361 to 370361-370
  38. Pages 371 to 380371-380
  39. Pages 381 to 390381-390
  40. Pages 391 to 400391-400
  41. Pages 401 to 410401-410
  42. Pages 411 to 420411-420
  43. Pages 421 to 430421-430
  44. Page 431431

The file

Revision and size

RevisionP/N 84-000044 RevA, 2015
PublisherMicroscan Systems, Inc.
Pages431
PDF3.5 MB
TextText from the PDF itself; page 1 is a scan, read by OCR, which may hold reading errors.

The first pages · 3 of 431

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 431
Page 2
Page 2of 431
Page 3
Page 3of 431

More documents · 1

For the same models