Page 281
Camera and IP Setup
Window of Interest by ESP 1. From the Camera menu, click the WOI tab to bring up Window of Interest. If you haven’t already captured an image, click the Capture and Decode button to decode the present image. If successful, the Good Read indicator on the WOI tab will be green and the symbol will appear in the pane below. Note: You can resize the image by clicking and dragging the ESP window from the lower right corner. This is useful where very small symbols are being read. 2. Click and drag your cursor over the symbol that you want to isolate for reading. Notice that the surrounding area goes black. You can use the handles on the image area that you have just drawn to resize the region of interest. You can also click on the center of the window of interest and move it. 3. Test the new settings in Read Rate Mode.
Note: To remove the window of interest, click the Reset button or just click anywhere in the WOI pane. Note that all pixels not in the WOI are defined as black. Because the imager has far less processing to do in a smaller window, Read Rates typically increase dramatically. One possible downside is that the chance of missing a symbol increases with the smaller window. Always verify that your WOI will be large enough to allow for any random movement of symbols in your field of view. EZ Match User Manual
11-11
Page 282
Window of Interest
Window of Interest by Serial Command The figure below shows where to locate the start position of the row and column pointers and how to measure the column depth and row width dimensions. WOI Row Pointer
WOI Column Pointer
WOI Row Depth
WOI Column Width
Top (Row Pointer) Definition: Serial Cmd: Default: Options:
Defines the row position of the upper-left starting point of the window. <K516,row pointer,column pointer,row depth,column width> 0 Monochrome EZ Match: 0 to (1024 – row depth) EZ Match Color: 0 to (832 – row depth)
Left (Column Pointer) Definition: Serial Cmd: Default: Options:
Defines the column position of the upper-left starting point of the window. <K516,row pointer,column pointer,row depth,column width> 0 Monochrome EZ Match: 0 to (1280 – column width) EZ Match Color: 0 to (2048 – column width)
Important: The column pointer setting must be an even value. If a user enters an odd value, it will be decreased automatically to the nearest even value. For example, if a user enters a setting of 101, it will automatically be reduced to 100 (although a user request for this setting would still show 101).
11-12
EZ Match User Manual
Page 283
Camera and IP Setup
Height (Row Depth) Definition: Serial Cmd: Default: Options:
Defines the size, in rows, of the window. Maximum value is defined as the maximum row size of the image sensor minus the Top value. <K516,row pointer,column pointer,row depth,column width> Monochrome EZ Match: 1024 EZ Match Color: 832 Monochrome EZ Match: 3 to (1024 – row pointer) EZ Match Color: 3 to (832 – row pointer)
Width (Column Width) Definition: Serial Cmd: Default: Options:
Defines the column position of the upper-left starting point of the window. <K516,row pointer,column pointer,row depth,column width> Monochrome EZ Match: 1280 EZ Match Color: 2048 Monochrome EZ Match: 8 to (1280 – column pointer) EZ Match Color: 8 to (2048 – column pointer)
Important: The column width value must be a modulus 8 value. If a user enters a non-modulus 8 value, it will be decreased automatically to the nearest modulus 8 value. For example, if a user enters a setting of 639, it will automatically be reduced to 632 (although a user request for this setting would still show 639).
EZ Match User Manual
11-13
Page 284
IP Database
IP Database The IP Database allows the user to manage multiple configuration profiles. It is a useful tool in applications that require several different imager configurations to be applied sequentially, and it allows the user to perform far more complex operations than would be possible with only one set of configuration parameters. See Chapter 12, IP Database, for full documentation of this feature.
IP Database view, set for 5 Active Indexes, with Capture Settings highlighted
11-14
EZ Match User Manual
Page 285
Camera and IP Setup
Dynamic Setup Dynamic Setup is used to calculate image capture timing during a read cycle. Without proper timing, the imager will not be able to decode all symbols in a read cycle. An external trigger is used to activate image captures so the user can make timing adjustments as capture events occur.
The user can control Capture #, Number of Captures, and Number of Symbols using these spin boxes.
Read Rate is represented graphically in real-time as the user makes adjustments to the time delay between image captures.
The Delay Adjustment slider allows the user extremely precise control of the time delays between image captures in a read cycle. Delay values are shown in seconds in the field above the slider. The Coarse and Fine Delay Adjustment options determine whether larger or smaller adjustment increments will be used.
EZ Match User Manual
11-15
Page 286
Camera Settings
Camera Settings Camera parameters are typically obtained during the calibration process, and do not necessarily need to be modified directly.
Shutter Speed Usage: Definition:
Serial Cmd: Default: Options:
Faster shutter speeds reduce blurring in faster applications. Slower shutter speeds are useful in slower applications and lower contrast applications. Sets the exposure or integration time for the image sensor pixels. The shutter speed setting in relation to the speed of the object is critical. If a slow shutter speed is selected to capture fast-moving objects, blurring or smearing of the image will occur. As shutter speed is increased, more light and gain become necessary, because the pixels’ exposure time has decreased. <K541,shutter speed,gain> 45 15 to 12,500
Gain Usage: Definition:
Serial Cmd: Default: Options: 11-16
Can be used to adjust pixel grayscale values for readability. Sets the gain value for the image sensor. This setting can be configured through calibration, which is the recommended method. A higher gain value will increase the brightness of the image, but the visual noise reduction performance of the system is reduced. Before configuring gain settings, the desired shutter speed should already be set and the gain should be configured to optimize the shutter speed setting. Each of the image sensor’s colors has a separate gain setting, and the White Balance adjustment provides gain offsets for color channels R (red), G (green), and B (blue) to provide consistent white across the image. Adjustments to both the R and B channels are usually required. The gain value that is set here is the base gain value for all colors. If a color requires additional gain to provide white balance, the offset is added to this gain value. However, when in the analog gain range, the gain + offset cannot exceed 42, and when in the digital gain range, the gain + offset cannot exceed 48. For optimal white balance, avoid setting gain near these values. Note: Microscan recommends using only the analog gain range (0 to 42). Image quality is degraded within the digital gain range (43 to 48). <K541,shutter speed,gain> 30 Analog gain: 0 to 42 Digital gain: 43 to 48 EZ Match User Manual
Page 287
Camera and IP Setup
Focal Distance (Read-Only) Definition: Serial Cmd: Default: Options:
This command returns the imager’s factory preset focal distance. <K525,focal distance> 400 (4”) N/A (Focal Distance is factory preset.)
Focal Distance Table (Read-Only) Number of Focal Distances Definition: Serial Cmd: Default: Options:
Specifies the number of focal distances supported by the imager (1). <K526,number of focal distances,focal distance> 1 N/A (Focal Distance is factory preset.)
Focal Distance Definition: Serial Cmd: Default: Options:
Returns the Imager’s factory preset focal distance. <K526,number of focal distances,focal distance> Returns the imager’s factory preset Focal Distance value. N/A (Focal Distance is factory preset.)
EZ Match User Manual
11-17
Page 288
Pixel Sub-Sampling
Pixel Sub-Sampling Definition: Usage: Default: Options:
The camera can be enabled to sub-sample pixels in the specified image frame. Sub-sampling can be set to either 4:1 or 16:1. These ratios signify the sampling rate. <K542,sub-sampling> Disabled 0 = Disabled 1 = 4:1 2 = 16:1
4:1 At this sampling rate, 1 pixel is output for every 4 pixels sampled. The image will be sampled 2:1 vertically and 2:1 horizontally, for a combined 4:1 ratio. An image with dimensions of 640 x 480 will be scaled to 320 x 240.
16:1 At this sampling rate, 1 pixel is output for every 16 pixels sampled. The image will be sampled 4:1 vertically and 4:1 horizontally, for a combined 16:1 ratio. An image with dimensions of 640 x 480 will be scaled to 160 x 120.
11-18
EZ Match User Manual
Page 289
Camera and IP Setup
IP Threshold Threshold Mode Usage:
Definition:
Serial Cmd: Default: Options:
Fixed Mode works best when decode time must be as short as possible and the reflectance and illumination of the symbol area is uniform and unchanging. Cycle Fixed Mode is useful in applications where decode time can be slightly longer, and reflectance and illumination of the symbol area is uniform and unchanging. Otherwise, Adaptive Mode is the preferred mode. This value switches the image processing threshold mode between the Adaptive, Fixed, and Cycle Fixed modes. An adaptive routine sets the light/dark threshold using data acquired from the current read. A fixed routine applies the same gray scale threshold value to each and every symbol. A cycle fixed routine loops through a pre-defined range of values (Cycle Min to Cycle Max) by pre-defined increments (Cycle Step). <K512,threshold mode,threshold value,cycle min,cycle max,cycle step, adaptive contrast percent> Adaptive 0 = Adaptive 1 = Fixed 2 = Cycle Fixed
Threshold Value Usage: Definition: Serial Cmd: Default: Options:
A higher value will increase the threshold for distinguishing between light and dark elements. Determines how the imager will distinguish light pixels from dark pixels. This value is used for Fixed Mode only. When Adaptive Mode is set, this value is ignored. <K512,threshold mode,threshold value,cycle min,cycle max,cycle step, adaptive contrast percent> 128 0 to 255
Cycle Min Definition: Starting value of the cycle mode. Serial Cmd: <K512,threshold mode,threshold value,cycle min,cycle max,cycle step, adaptive contrast percent> Default: 0 Options: 0 to 255 Important: Cycle Min must be a smaller numerical value than Cycle Max. EZ Match User Manual
11-19
Page 290
IP Threshold
Cycle Max Definition: Ending value of the cycle mode. Serial Cmd: <K512,threshold mode,threshold value,cycle min,cycle max,cycle step, adaptive contrast percent> Default: 255 Options: 0 to 255 Important: Cycle Max must be a greater numerical value than Cycle Min.
Cycle Step Definition: Serial Cmd: Default: Options:
The numerical value of a single cycle mode increment. <K512,threshold mode,threshold value,cycle min,cycle max,cycle step,adaptive contrast percent> 10 0 to 255
Adaptive Contrast Percent Definition:
Serial Cmd: Default: Options:
11-20
A percentage value that adjusts the adaptive threshold map; useful in decoding underprinted or overprinted symbols. Example: If an adaptive contrast value of 110 is set, then the adaptive threshold will be 110% of the original contrast values. <K512,threshold mode,threshold value,cycle min,cycle max,cycle step, adaptive contrast percent> 100 1 to 200 (percent)
EZ Match User Manual