Page 131
Read Cycle
External Level Initiate Read Cycle: Object #1, moving in front of the detector beam, causes a change in the trigger state, which initiates the read cycle. End Read Cycle: The same object, moving out of the detector beam, causes another change in the trigger state, which ends the read cycle.
Usage:
Definition:
Serial Cmd:
This mode is effective in an application where the speeds of the conveying apparatus are variable and the time the imager spends reading each object is not predictable. It also allows the user to determine if a No Read has occurred. External Level allows the read cycle (active state) to begin when a trigger (change of state) from an external sensing device is received. The read cycle persists until the object moves out of the sensor range and the active trigger state changes again. <K200,2> Important: Level and Edge apply to the active logic state (Negative or Positive) that exists while the object is in a read cycle, between the rising edge and the falling edge. Rising edge is the trigger signal associated with the appearance of an object. Falling edge is the trigger signal associated with the subsequent disappearance of the object. This applies both to External Level and External Edge.
External Edge Initiate Read Cycle: Object # 1, moving in front of the detector beam, causes a change in the trigger state, which initiates the read cycle. Initiate Second Read Cycle: Object # 2, moving in front of the detector beam, causes another change in the trigger state. This signal initiates a new read cycle and ends the previous read cycle unless Timeout is enabled and a Good Read or timeout has not occured.
Usage: Definition:
Serial Cmd:
This mode is highly recommended in any application where conveying speed is constant, or if spacing, object size, or read cycle timeouts are consistent. External Edge, as with Level, allows the read cycle (active state) to begin when a trigger (change of state) from an external sensing device is received. However, the passing of an object out of sensor range does not end the read cycle. The read cycle ends with a Good Read output, or, depending on the End of Read Cycle setting, a timeout or new trigger occurs. <K200,3>
EZ Match User Manual
6-9
Page 132
Trigger Mode and Duration
Serial Data Usage: Definition:
Serial Cmd:
Serial Data is effective in a highly controlled environment where the host knows precisely when the object is in the field of view. It is also useful in determining if a No Read has occurred. In Serial Data, the imager accepts an ASCII character from the host or controlling device as a trigger to start a read cycle. A Serial Data trigger behaves the same as an External Edge trigger. Serial commands are entered inside angle brackets, as shown here: <t>. <K200,4> Note: In Serial Data, sending a non-delimited start serial character will start a read cycle; however, a non-delimited stop serial character has no effect.
Serial Data and Edge Usage:
Definition: Serial Cmd:
Serial Data and Edge is seldom used but can be useful in an application that primarily uses an external sensing device but occasionally needs to be triggered manually. An auxiliary terminal can be connected to the auxiliary port so the user can send the serial trigger character through the imager to the host. In this mode the imager accepts either a serial ASCII character or an external trigger pulse to start the read cycle. <K200,5> Note: In Serial Data, sending a non-delimited start serial character will start a read cycle; however, a non-delimited stop serial character has no effect.
6-10
EZ Match User Manual
Page 133
Read Cycle
Trigger Filter Duration Usage: Definition: Serial Cmd: Default: Options:
Trigger Filter Duration allows the imager to disregard false trigger events. When Trigger Mode is set to either External Edge or External Level, the read cycle’s active state must be delayed until the specified filter duration has elapsed. The imager will trigger at the end of that duration. <K200,trigger mode,trigger filter duration> 313 (in 32µs increments) 1 to 65535 (corresponding with 32µs to 2.10 seconds in 32µs steps) Note: If Trigger Mode is set to External Edge, the imager will trigger only after the active state has been delayed for the specified filter duration. Note: If Trigger Mode is set to External Level, the imager will trigger once the active state has been delayed for the specified filter duration after the appearance of an object’s active edge. In addition, the active state must be delayed for the specified filter duration after the disappearance of the object’s falling edge for the trigger to be rendered inactive.
EZ Match User Manual
6-11
Page 134
External Trigger Polarity
External Trigger Polarity Usage: Definition: Serial Cmd: Default: Options:
6-12
Allows users to select the trigger polarity that will be used in their application. Determines the active state of the trigger signal applied to the cable input of the imager. <K202,active state> Positive 0 = Negative 1 = Positive
EZ Match User Manual
Page 135
Read Cycle
Serial Trigger Usage: Definition:
Allows the user to define the trigger character and delimiters that start and stop the read cycle. A serial trigger is considered an online host command and requires the same command format as all host commands. It must be entered within angle bracket delimiters < > or, in the case of non-delimited triggers, it must define individual start and stop characters.
Serial Trigger Character (Delimited) Usage: Definition: Serial Cmd: Default: Options:
Allows the user to define the trigger character that initiates the read cycle. A single ASCII host serial trigger character that initiates the read cycle. A delimited trigger character is one that either starts or ends the read cycle and is enclosed by delimiters such as < >. <K201,serial trigger character> Space bar Any single ASCII character, including control characters, except NUL (00 in hex), an existing host command character, or an on-line protocol character. Control characters entered on the command line are displayed in the menu as mnemonic characters. Note: Serial Data or Serial Data and Edge triggering mode must be enabled for Serial Trigger Character to take effect. Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K201h,3C> For >: <K201h,3E> For , : <K201h,2C> See ASCII Character Entry Modifier on page 4-33 for a detailed explanation of how to enter ASCII characters as hex values.
EZ Match User Manual
6-13
Page 136
Start Trigger Character (Non-Delimited)
Start Trigger Character (Non-Delimited) Usage: Definition:
Serial Cmd: Default: Options:
Useful in applications where different characters are required to start a read cycle. A single ASCII host serial trigger character that starts the read cycle and is not enclosed by delimiters such as < and >. Non-delimited Start characters can be defined and will function according to the trigger event. When defining Start trigger characters, the following rules apply: • In External Edge the imager looks only for the Start trigger character and ignores any Stop trigger character that may be defined. • In External Level the Start trigger character begins the read cycle and the Stop trigger character ends it. Note that even after a symbol has been decoded and the symbol data transmitted, the imager remains in External Level trigger read cycle until a Stop character is received. • In Serial Data and Edge trigger mode, either a Start trigger character or a hardware trigger can start an edge trigger read cycle. <K229,start character> NUL (00 in hex; disabled) Two hex digits representing any ASCII character except XON and XOFF. Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K229h,3C> For >: <K229h,3E> For , : <K229h,2C> See ASCII Character Entry Modifier on page 4-33 for a detailed explanation of how to enter ASCII characters as hex values.
6-14
EZ Match User Manual
Page 137
Read Cycle
Stop Trigger Character (Non-Delimited) Usage: Definition:
Serial Cmd: Default: Options:
Useful in applications where different characters are required to end a read cycle. A single ASCII host serial trigger character that ends the read cycle and is not enclosed by delimiters such as < and >. Non-delimited Stop characters can be defined and will function according to the trigger event. When defining Stop trigger characters, the following rules apply: • In External Edge the imager looks only for the Start trigger character and ignores any Stop trigger character that may be defined. • In External Level the Start trigger character begins the read cycle and the Stop trigger character ends it. Note that even after a symbol has been decoded and the symbol data transmitted, the imager remains in External Level trigger read cycle until a Stop character is received. • In Serial Data and Edge trigger mode, either a Start trigger character or a hardware trigger can start an edge trigger read cycle. <K230,stop character> NUL (00 in hex; disabled) Two hex digits representing an ASCII character. Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K230h,3C> For >: <K230h,3E> For , : <K230h,2C> See ASCII Character Entry Modifier on page 4-33 for a detailed explanation of how to enter ASCII characters as hex values.
EZ Match User Manual
6-15
Page 138
End of Read Cycle
End of Read Cycle Definition:
The read cycle is the time during which the imager will attempt to capture and decode a symbol or detect a tube or cap. A read cycle can be ended by a timeout, a new trigger, or by the last frame in a capture sequence or a combination of the above. Note: End of Read Cycle settings apply to the entire read cycle, while Multi-Operation Timeout applies only to the specific operation (1 through 3) for which it is defined.
End of Read Cycle Mode
Note: When operating in Continuous Read or Continuous Read 1 Output, the imager is always in the read cycle. Serial Cmd: Default: Options:
<K220,end of read cycle,read cycle timeout> Timeout 0 = Timeout 1 = New Trigger 2 = Timeout and New Trigger 3 = Last Frame 4 = Last Frame and New Trigger
Timeout Usage:
Definition:
6-16
Typically used with Serial Data and Edge and Continuous Read 1 Output. It is effective in highly controlled applications when the maximum length of time between objects can be predicted. It assures that a read cycle ends before the next symbol appears, giving the system extra time to decode and transmit the data to the host. Timeout ends the read cycle, causing the reader to stop reading symbols and send the symbol data or No Read message when the time set in Timeout elapses (times out), if When to Output is set to End of Read Cycle. If in Continuous Read 1 Output, a timeout initiates a new read cycle and allows the same symbol to be read again. With External Edge, Serial Data, or Serial Data and Edge enabled, a timeout ends the read cycle and symbol data or a No Read message is sent to the host. With External Level enabled, the read cycle does not end until the falling edge trigger occurs or a timeout occurs. The next read cycle does not begin until the next rising edge trigger.
EZ Match User Manual
Page 139
Read Cycle
New Trigger Usage: Definition:
New Trigger is an effective way to end a read cycle when objects move past the reader at irregular intervals (not timing-dependent). New Trigger ends the current read cycle and initiates a new one when a new trigger occurs. New Trigger refers only to a rising edge trigger. With External Edge, Serial Data, or Serial Data and Edge enabled, an edge or serial trigger ends a read cycle and initiates the next read cycle. In the case of External Level, a falling edge trigger ends the read cycle but the next read cycle does not begin until the occurrence of the next rising edge trigger.
Timeout and New Trigger Usage: Definition:
Useful in applications that require an alternative way to end the read cycle. For example, if an assembly line should stop completely or the intervals between objects are highly irregular. Timeout and New Trigger is identical to Timeout except that a timeout or a new trigger (whichever occurs first) ends the read cycle.
Last Frame Usage: Definition:
Useful in applications in which the number of captures needed can be defined but the timeout duration varies. Last Frame only applies to Rapid Capture Mode.
Last Frame and New Trigger Usage: Definition:
Useful in applications in which line speeds are irregular and a new labelled object could appear before the last frame in a Rapid Capture sequence. Last Frame and New Trigger is identical to New Trigger except that a new trigger or last frame (whichever occurs first) ends the read cycle.
Read Cycle Timeout Definition: Serial Cmd: Default: Options:
Read Cycle Timeout is the duration of the read cycle. <K220,end of read cycle,read cycle timeout> 250 (x10 ms or 2.5 seconds) 1 to 65535
EZ Match User Manual
6-17
Page 140
Capture Mode
Capture Mode Definition: Serial Cmd: Default: Options:
Capture Mode relates to the way that images are captured and processed. <K241,capture mode,number of captures,rapid capture mode,pre-processing> Continuous Capture 0 = Rapid Capture 1 = Continuous Capture
Rapid Capture Definition:
In a rapid capture mode, one or multiple captures (as many as 32) can be taken at an interval specified by the time-between-captures parameter. In this mode, the only limiting time factor is integration and transfer timing.
Continuous Capture Usage: Definition:
Continuous Capture is useful in applications with slower line speeds or where symbol spacing may be random or not time-dependent. In Continuous Capture Mode, image captures are taken throughout the read cycle in a multi-buffered format (see diagram below). The imager begins processing the first captured image at the same time that it captures the second image. Captures will continue occurring throughout the read cycle until an end condition occurs, such as a timeout, a new trigger, the last frame in a capture sequence, or a combination of the above. Capture Start of Read Cycle
1 2 3
4
5
End of read cycle
Processing time
6-18