Page 181

Symbologies

MicroPDF417 Usage: Definition: Serial Cmd: Default: Options:

Used for labelling small items that need large data capacity. A variant of PDF417, a very efficient and compact stacked symbology that can encode up to 250 alphanumeric characters or 366 numeric characters per symbol. <K485,status,[unused],fixed symbol length status,fixed symbol length> Disabled 0 = Disabled 1 = Enabled

Fixed Symbol Length Status (MicroPDF417) Serial Cmd: Default: Options:

<K485,status,[unused],fixed symbol length status,fixed symbol length> Disabled 0 = Disabled 1 = Enabled

Fixed Symbol Length (MicroPDF417) Usage: Definition:

Serial Cmd: Default: Options:

Used to increase data integrity by ensuring that only one symbol length will be accepted. When enabled, the MicroPDF417 symbol must contain the same number of characters as the symbol length setting before it can be considered a Good Read. The imager will ignore any symbol not having the specified length. <K485,status,[unused],fixed symbol length status,fixed symbol length> 10 1 to 366

Note: Fixed Symbol Length Status must be enabled for Fixed Symbol Length to take effect.

EZ Match User Manual

7-31

Page 182

Composite

Composite When set to Enabled or Required, will attempt to decode the composite component of a linear symbol. The linear symbol can be DataBar-14, DataBar Expanded, DataBar Limited, EAN-128, UPC-A, EAN-13, EAN-8, and UPC-E. Usage: Definition: Serial Cmd: Default: Options:

Allows reading by both linear and 2D readers. Combines 2D and linear width modulated symbology on the same symbol where different messages can be read by each reader type. <K453,mode,separator status,separator> Disabled 0 = Disabled 1 = Enabled 2 = Required

Enabled

If set to Enabled, the imager only decodes the linear component, and it will only output the linear component.

Required

If set to Required, the imager must decode both the linear and the composite components; otherwise it outputs a No Read.

Separator Status (Composite) Usage: Definition: Serial Cmd: Default: Options:

Allows the user to distinguish between the main and Supplemental symbols. Separates the linear and the composite component. <K453,mode,separator status,separator> Disabled 0 = Disabled 1 = Enabled

Separator Character (Composite) As required by the application. Allows the user to change the separator character from a comma to a new character. Serial Cmd: <K453,mode,separator status,separator> Default: , (comma) Options: Any ASCII character Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K453h,,,3C> For >: <K453h,,,3E> For , : <K453h,,,2C> See ASCII Character Entry Modifier on page 4-33 for a detailed explanation of how to enter ASCII characters as hex values. Usage: Definition:

7-32

EZ Match User Manual

Page 183

Symbologies

Narrow Margins / Symbology Identifier Narrow Margins Used when the leading and trailing edges of the symbols are smaller than the standard margin or other objects encroach into the margins. Definition: Allows the imager to read 1D symbols with quiet zones less than 8 times the width of the narrow bar element. “Quiet zone” is the space at the leading and trailing ends of a symbol. When Narrow Margins is set to Enabled, the imager uses a 5x margin requirement for standard linear symbols. Serial Cmd: <K450,narrow margins,symbology identifier status> Default: Disabled Options: 0 = Disabled 1 = Enabled Note: Do not use Narrow Margins with Large Intercharacter Gap Enabled with Code 39. Usage:

Symbology Identifier Definition:

Symbology ID is an ISO/IEC 16022 standard prefix set of characters that identifies the symbol type. When enabled, the imager analyzes and identifies the symbology and adds a three character identifying prefix to the data: • ] (closed bracket character) indicating the presence of a symbology identifier. • A = Code 39 C = Code 128 E = UPC/EAN F = Codabar G = Code 93 I = Interleaved 2 of 5 L = PDF417 Q = QR Code b = BC412 d = Data Matrix e = GS1 DataBar (RSS) p = Pharmacode

Serial Cmd: Default: Options:

• Modifier Example: ]d indicates a Data Matrix symbol. <K450, narrow margins,symbology identifier status> Disabled 0 = Disabled 1 = Enabled

EZ Match User Manual

7-33

Page 184

Narrow Margins / Symbology Identifier

Explanation of Modifiers for Code 39, Codabar, and Interleaved 2/5 • For Code 39, Codabar, and Interleaved 2 of 5, the modifier indicates Check Character and Check Character Output status. • For Code 39 only, Full ASCII must be enabled to see modifiers 4, 5, and 7. Modifier

Check Character

0 1 3 4 5 7

Disabled Enabled Enabled Disabled Enabled Enabled

Check Character Output N/A Enabled Disabled N/A Enabled Disabled

Full ASCII conversion performed (Code 39 only) No No No Yes Yes Yes

Example: ]A5 indicates a Code 39 symbol with Check Character and Check Character Output enabled and Full ASCII conversion performed.

Explanation of Modifiers for Code 128 and QR Code • For Code 128, a 1 indicates EAN-128; otherwise the modifier is 0. • For QR Code, a 0 indicates Model 1; a 1 indicates Model 2. • For all other symbologies, the modifier is 0.

7-34

EZ Match User Manual

Page 185

Contents

8 I/O Parameters

I/O Parameters by ESP ................................................................................................................ 8-2 I/O Parameters Serial Commands ............................................................................................... 8-3 Symbol Data Output ..................................................................................................................... 8-5 No Read Message........................................................................................................................ 8-8 Bad Symbol Message ................................................................................................................ 8-10 No Symbol Message .................................................................................................................. 8-10 1D / Stacked Symbology Qualification ....................................................................................... 8-11 2D Symbology Qualification ....................................................................................................... 8-12 Read Duration Output ................................................................................................................ 8-18 Output Indicators ........................................................................................................................ 8-19 Beeper........................................................................................................................................ 8-23 LED Configuration ...................................................................................................................... 8-24 Serial Verification ....................................................................................................................... 8-25 EZ Button ................................................................................................................................... 8-27 EZ Button Modes........................................................................................................................ 8-29 Configurable Output 1 ................................................................................................................ 8-31 Trend Analysis Output 1............................................................................................................. 8-34 ISO/IEC 16022 Symbol Quality Output 1 ................................................................................... 8-37 Diagnostics Output 1 .................................................................................................................. 8-40 Tube/Cap Detection Output 1..................................................................................................... 8-41 Configurable Output 2 ................................................................................................................ 8-43 Trend Analysis Output 2............................................................................................................. 8-43 ISO/IEC 16022 Symbol Quality Output 2 ................................................................................... 8-43 Diagnostics Output 2 .................................................................................................................. 8-43 Tube/Cap Detection Output 2..................................................................................................... 8-44 Configurable Output 3 ................................................................................................................ 8-45 Trend Analysis Output 3............................................................................................................. 8-45 ISO/IEC 16022 Symbol Quality Output 3 ................................................................................... 8-45 Diagnostics Output 3 .................................................................................................................. 8-45 Tube/Cap Detection Output 3..................................................................................................... 8-46 Frame Information ...................................................................................................................... 8-47 Image Output.............................................................................................................................. 8-48 Database Identifier Output ......................................................................................................... 8-51 Quality Output ............................................................................................................................ 8-52 Power-On/Reset Counts ............................................................................................................ 8-53 Time Since Reset ....................................................................................................................... 8-54 Service Message........................................................................................................................ 8-55 EZ Trax Output........................................................................................................................... 8-56

This section includes instructions on setting up conditions for changing input/output electrical transitions for control of the imager’s internal and external devices. EZ Match User Manual

8-1

Page 186

I/O Parameters by ESP

I/O Parameters by ESP

Click the Parameters button and then the I/O tab.

To change a setting, double-click the setting and use your cursor to scroll through the options.

To open nested options, single-click the +.

8-2

EZ Match User Manual

Page 187

I/O Parameters

I/O Parameters Serial Commands <K406,power-on,resets,power-on saves,power-on flash saves, power-on tube/cap library saves> Time Since Reset <K407,hours,minutes> Service Message <K409,status,service message,threshold,resolution> <K701,serial command echo status,serial command beep status, Serial Verification control/hex output> Beeper <K702,status> Quality Output <K704,quality output separator,decodes/trigger status> Symbol Data Output <K705,symbol data output status,when to output> Read Duration Output <K706,status,separator> No Read Message <K714,status,message> Bad Symbol Message <K715,[unused],message> No Symbol Message <K716,[unused],message> <K717,minimum number of bars,minimum number of qualified 1D/Stacked Symbology Qualification scan lines,start/stop status> <K718,finder pattern status,symbol size status,symbol size 1, symbol size 2,symbol size tolerance,dimension status,dimension 2D Symbology Qualification 1,dimension 2,dimension tolerance,orientation status,orientation value> Frame Information <K734,output frame number,output coordinates> LED Configuration <K737,LED mode,ISO/IEC 16022 grade> <K739,image output mode,communication port,file format,JPEG Image Output quality> <K750,green flash LED status,target pattern LED status,green Target/Flood LEDs flash duration> <K757,status,comm port,image mode,image format, JPEG quality, EZ Trax Output object info output,grade output,color> Database Identifier Output <K759,status,separator> <K770,global status,default on power-on,load IP database,save for EZ Button power-on> EZ Button Modes <K771,single beep,two beeps,three beeps,four beeps> <K780,trend analysis mode,number of triggers,number to output Trend Analysis Output 1 on,decodes/trigger threshold> <K781,trend analysis mode,number of triggers,number to output Trend Analysis Output 2 on,decodes/trigger threshold> <K782,trend analysis mode,number of triggers,number to output Trend Analysis Output 3 on,decodes/trigger threshold> Diagnostics Output 1 <K790,unused 1,service unit> Diagnostics Output 2 <K791,unused 1,service unit> Diagnostics Output 3 <K792,unused 1,service unit> <K800,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity, ISO/IEC 16022 Symbol Quality Output 1 axial non-uniformity threshold,output on unused ECC,unused ECC threshold> Power On/Reset Counts

EZ Match User Manual

8-3

Page 188

I/O Parameters Serial Commands <K801,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity, axial non-uniformity threshold,output on unused ECC,unused ECC threshold> <K802,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity, ISO/IEC 16022 Symbol Quality Output 3 axial non-uniformity threshold,output on unused ECC,unused ECC threshold> Configurable Output 1 <K810,output on,output state,pulse width,output mode> Configurable Output 2 <K811,output on,output state,pulse width,output mode> Configurable Output 3 <K812,output on,output state,pulse width,output mode> Tube/Cap Detection Output 1 <K860,mode,output on> Tube/Cap Detection Output 2 <K861,mode,output on> Tube/Cap Detection Output 3 <K862,mode,output on>

ISO/IEC 16022 Symbol Quality Output 2

8-4

EZ Match User Manual

Page 189

I/O Parameters

Symbol Data Output Symbol Data Output Status Note: Symbol Data Output relates to data and should not be confused with Outputs 1, 2, and 3 listed in the Output Parameters which describe output states and functions. Usage: Definition: Serial Cmd: Default: Options:

Useful when the host needs symbol data only under certain conditions. Defines the conditions under which decoded symbol data is transmitted to the host. <K705,symbol data output status,when to output> Good Read 0 = Disabled 1 = Match 2 = Mismatch 3 = Good Read

Note: Symbol Data Output Status, if set to Match or Mismatch, will not take effect unless Matchcode Type is enabled and a master symbol is loaded into memory.

Disabled Usage:

Definition:

It is useful when an application only needs to use the discrete outputs and can allow the imager to do the decision-making. When Disabled, the host does not need the symbol data and the communication lines are used only for setup and status checks. When set to Disabled, the imager will not transmit any data that is generated during a read cycle (symbols, No Reads, etc.)

Match Usage: Definition:

Match is used in an application that requires specific symbol information and needs to sort, route, or verify based on matching the specific symbol data. When set to Match, the imager transmits symbol data whenever a symbol matches a master symbol. However, if Matchcode Type is Disabled, it transmits on any Good Read.

Note: A No Read can still be transmitted if Enabled.

Mismatch Usage: Definition:

Mismatch is typically used as a flag within the host system to prevent an item from being routed in the wrong container. With Mismatch enabled, the imager transmits symbol data whenever the symbol data information does NOT match the master symbol.

Note: A No Read can still be transmitted if Enabled. EZ Match User Manual

8-5

Page 190

Symbol Data Output

Good Read Usage: Definition:

Good Read is used when an application requires all symbol data to be transmitted. It’s typically used in tracking applications in which each object is uniquely identified. With Good Read enabled, the imager transmits symbol data on any Good Read regardless of Matchcode Type setting. Note: A No Read can still be transmitted if Enabled.

8-6

EZ Match User Manual