Page 171
Symbologies
UPC / EAN Usage:
Definition:
Serial Cmd: Default: Options:
Used primarily in point-of-sale applications in the retail industry. It is commonly used with Microscan readers in applications in combination with Matchcode when there is a need to verify that the right product is being placed in the right packaging. UPC (Universal Product Code) is a fixed length, numeric, continuous symbology. UPC can have two- or five-digit supplemental bar code data following the normal code. The UPC Version A (UPC, A) symbol is used to encode a 12 digit number. The first digit is the number system character, the next five are the manufacturer number, the next five are the product number, and the last digit is the checksum character. When enabled, the imager will read UPC Version A and UPC Version E only. <K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> Disabled 0 = Disabled 1 = Enabled
EAN Status Usage: Definition:
Serial Cmd: Default: Options:
EAN is the European version of the UPC symbology and is used in European market applications. Note: UPC must be enabled for EAN to take effect. EAN is a subset of UPC. When enabled, the imager will read UPC Version A, UPC Version E, EAN 13, and EAN 8. It also appends a leading zero to UPC Version A symbol information and transmits 13 digits. If transmitting 13 digits when reading UPC Version A symbols is not desired, disable EAN. Note: The extra character identifies the country of origin. <K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> Disabled 0 = Disabled 1 = Enabled
EZ Match User Manual
7-21
Page 172
UPC / EAN
Supplementals Status (UPC / EAN) Usage: Definition: Serial Cmd: Default: Options:
Reads Supplementals typically used in publications and documentation. A supplemental is a 2 to 5 digit symbol appended to the main symbol. When set to Enabled or Required, the imager reads supplemental code data that has been appended to the standard UPC or EAN codes. <K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> Disabled 0 = Disabled 1 = Enabled 2 = Required
Disabled UPC Supplementals will not be decoded.
Enabled When enabled, the imager will try to decode a main and a supplemental. However, if a supplemental is not decoded, the main will be sent by itself at the end of the read cycle.
Required When set to Required, both the main and the supplemental symbols must be read or a single No Read condition results. For example, if Supplementals is set to Required, Separator is enabled, and an asterisk is defined as the UPC separator character. Then the data is displayed as: MAIN * SUPPLEMENTAL. Note: Under no circumstances will the supplemental symbol data be sent without a main symbol. Note: If additional symbols - other than the main or supplemental - will be read in the same read cycle, Number of Symbols should be set accordingly.
Separator Status (UPC / EAN) Usage: Definition: Serial Cmd: Default: Options: 7-22
Allows users to distinguish between the main and Supplemental symbols. A character can be inserted between the standard UPC or EAN symbology and the supplemental symbology when Supplementals is set to Enabled or Required. <K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> Disabled 0 = Disabled 1 = Enabled EZ Match User Manual
Page 173
Symbologies
Separator Character (UPC / EAN)
Note: If Separator Character has been changed to any other character and you wish to redefine the separator as a comma, you will need to use ESP. Usage: Definition: Serial Cmd: Default: Options:
As required by the application. Allows the user to change the separator character from a comma to a new character. <K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> , (comma) Any ASCII character
Note: Whenever Separator Character is defined as a comma ( , ) sending a <K473,s?> command will return the current settings, including the separator character comma which appears after the separator status comma. Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K473h,,,,,3C> For >: <K473h,,,,,3E> For , : <K473h,,,,,2C> See ASCII Character Entry Modifier on page 4-33 for a detailed explanation of how to enter ASCII characters as hex values.
EZ Match User Manual
7-23
Page 174
UPC / EAN
Supplemental Type (UPC / EAN) Usage: Definition: Serial Cmd: Default: Options:
As required by symbology used in application. Allows the user to select 2 character or 5 character supplements, or both. <K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> Both 0 = Both 1 = 2 characters only 2 = 5 characters only
Both Either 2 character or 5 character supplementals will be considered valid.
2 Characters Only Only two character supplementals will be considered valid.
5 Characters Only Only five character supplementals will be considered valid.
Format UPC-E as UPC-A (UPC / EAN) Definition:
Serial Cmd: Default: Options:
7-24
When disabled, the imager will output the version E symbols in their encoded 6-character format. When enabled, the imager will format the symbol as either a 12-character UPC-A symbol or an EAN-13 symbol, depending on the state of the EAN status parameter. This formatting reverses the zero suppression that is used to generate the symbol in the UPC specification. <K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> Disabled 0 = Disabled 1 = Enabled
EZ Match User Manual
Page 175
Symbologies
Pharmacode Usage: Definition:
Serial Cmd: Default: Options:
Used mostly with packaging for the pharmaceuticals industry. Encodes up to five different numbers, each with its own color, which may be entered in decimal or “binary” format with a 1 represented by a thick bar and a 0 represented by a thin bar. Bar width is independent of height. In decimal format, each part can be up to 999,999. In binary format, each input can have up to 19 ones and zeros. Important: When Pharmacode is enabled, other linear symbologies will not decode properly. Disable Pharmacode before reading other linear symbologies. <K477,status,fixed symbol length status,fixed symbol length,minimum number of bars,bar width status,direction,fixed threshold value> Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length Status (Pharmacode) Definition: Serial Cmd: Default: Options:
When enabled, the imager will check the symbol length against the symbol length field. If disabled, any length will be considered valid. <K477,status,fixed symbol length status,fixed symbol length,minimum number of bars,bar width status,direction,fixed threshold value> Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length (Pharmacode) Definition: Serial Cmd: Default: Options:
Specifies the exact number of bars that must be present for the imager to recognize and decode the Pharmacode symbol. <K477,status,fixed symbol length status,fixed symbol length,minimum number of bars,bar width status,direction,fixed threshold value> 5 1 to 16
Minimum Number of Bars (Pharmacode) Definition: Serial Cmd: Default: Options:
Sets the minimum number of bars that a Pharmacode symbol must have to be considered valid. <K477,status,fixed symbol length status,fixed symbol length,minimum number of bars,bar width status,direction,fixed threshold value> 2 1 to 16
EZ Match User Manual
7-25
Page 176
Pharmacode
Bar Width Status (Pharmacode) Definition:
Serial Cmd: Default: Options:
If set to Mixed, the imager will autodiscriminate between narrow bars and wide bars. If set to All Narrow, all bars will be considered as narrow bars. If set to All Wide, all bars will be considered as wide bars. If set to Fixed Threshold, it will use the fixed threshold value to determine whether the bars are narrow or wide. The Bar Width Status setting will be ignored when the imager is able to tell the difference between the narrow and the wide bars. <K477,status,fixed symbol length status,fixed symbol length,minimum number of bars,bar width status,direction,fixed threshold value> Mixed 0 = Mixed 1 = All Narrow 2 = All Wide 3 = Fixed Threshold
Direction (Pharmacode) Definition: Serial Cmd: Default: Options:
Specifies the direction in which a symbol can be read. <K477,status,fixed symbol length status,fixed symbol length,minimum number of bars,bar width status,direction,fixed threshold value> Forward 0 = Forward 1 = Reverse
Fixed Threshold Value (Pharmacode) Definition: Serial Cmd: Default: Options:
7-26
Used when Bar Width Status is set to Fixed Threshold. Defines the minimum difference in pixels that will distinguish a narrow bar from a wide bar. <K477,status,fixed symbol length status,fixed symbol length,minimum number of bars,bar width status,direction,fixed threshold value> 10 1 to 65535
EZ Match User Manual
Page 177
Symbologies
GS1 DataBar (RSS) Note: GS1 DataBar symbologies were previously known as “Reduced Space Symbology”, or “RSS”.
DataBar Expanded (RSS Expanded) Note: DataBar Expanded was previously known as “RSS Expanded”. Usage: Definition: Serial Cmd: Default: Options:
Used to encode primary and supplementary data in retail point-of-sale and other applications. DataBar Expanded is a variable length symbology that can encode supplementary information in addition to the 14-digit EAN item identification number and is capable of encoding up to 74 numeric or 41 alphabetic characters. <K484,status,fixed symbol length status,fixed symbol length> Disabled 0 = Disabled 1 = Enabled (non-stacked) 2 = Enabled (stacked and non-stacked)
Where appropriate, use 1 (non-stacked) for better performance over 2 (stacked and non-stacked).
Fixed Symbol Length Status (DataBar Expanded) Definition: Serial Cmd: Default: Options:
When enabled, the imager will check the symbol length against the symbol length field, minus the embedded check character. If disabled, any length would be considered valid. <K484,status,fixed symbol length status,fixed symbol length> Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length (DataBar Expanded) Usage: Definition: Serial Cmd: Default: Options:
Fixed Symbol Length helps prevent truncations and increases data integrity by ensuring that only one symbol length will be accepted. Specifies the exact number of characters that the imager will recognize (this does not include start, stop, and check character characters). The imager ignores any symbol not having the specified length. <K484,status,fixed symbol length status,fixed symbol length> 14 1 to 74
EZ Match User Manual
7-27
Page 178
GS1 DataBar (RSS)
DataBar Limited (RSS Limited) Note: DataBar Limited was previously known as “RSS Limited”. Usage: Definition: Serial Cmd: Default: Options:
DataBar Limited is best suited to laser and CCD readers. It is not recommended for omnidirectional slot scanners. Encodes a smaller 14-digit symbol (74 modules wide) that is not omnidirectional. <K483,status> Disabled 0 = Disabled 1 = Enabled
DataBar-14 (RSS-14) Note: DataBar-14 was previously known as “RSS-14”. Usage:
Used in the grocery, retail, and prescription drug industries where 14-digit EAN item identification may be needed.
Definition:
DataBar-14 (Reduced Space Symbology) is a fixed symbol length symbology that encodes 14 digits, including a 1-digit indicator. DataBar-14 is 96 modules wide. It can be stacked in two rows, it can read omnidirectionally if printed in full height, or horizontally if height-truncated for small marking. <K482,status> Disabled 0 = Disabled 1 = Enabled (non-stacked) 2 = Enabled (stacked; decode both stacked and non-stacked)
Serial Cmd: Default: Options:
Note: Where appropriate, use 1 (non-stacked) for better performance over 2 (stacked; decode both stacked and non-stacked).
7-28
EZ Match User Manual
Page 179
Symbologies
PDF417 Usage:
Definition:
Serial Cmd: Default: Options:
Used in applications where a large amount of information (over 32 characters) needs to be encoded within a symbol, typically where the symbol is transported from one facility to another. For example, an automobile assembly line might use a single symbol with multiple fields of information that will be read at several stations along the way, without reference to a database. A two-dimensional, multi-row (3 to 90), continuous, variable length symbology that has high data capacity for storing up to 2,700 numeric characters, 1800 printable ASCII characters, or 1100 binary characters per symbol. Each symbol character consists of 4 bars and 4 spaces in a 17-module structure. <K476,status,[unused],fixed symbol length status,fixed symbol length,[unused],codeword collection> Disabled 0 = Disabled 1 = Enabled
Note: Sending <a1> will cause PDF417 data to be prefaced with information consisting of ECC level (ECC Level n), number of rows (n Rows), number of columns (n Columns), number of informative code words (n Info Code Words) and the number of data characters (n Data Characters). This feature can be disabled by re-sending <a1>.
Fixed Symbol Length Status (PDF417) Serial Cmd: Default: Options:
<K476,status,[unused],fixed symbol length status,fixed symbol length,[unused],codeword collection> Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length (PDF417) Usage: Definition: Serial Cmd: Default: Options:
Used to increase data integrity by ensuring that only one symbol length will be accepted. When enabled, the PDF symbol must contain the same number of characters as the symbol length setting before it can be considered a Good Read. The imager will ignore any symbol not having the specified length. <K476,status,[unused],fixed symbol length status,fixed symbol length,[unused],codeword collection> 10 1 to 2710
Note: Fixed Symbol Length Status must be enabled for Fixed Symbol Length to take effect.
EZ Match User Manual
7-29
Page 180
PDF417
Codeword Collection (PDF417) Usage: Definition:
Serial Cmd: Default: Options:
7-30
Multiple Codeword Collection is useful in applications where portions of subsequent images can be read and pieced together so that no opportunity or time is lost to assemble codewords for decoding. When set to Multiple, PDF codewords are collected from multiple images and assembled throughout the read cycle until the read cycle ends or the symbol is fully decoded. It is important to note that when this feature is enabled, only one PDF symbol should be presented to the imager per read cycle. <K476,status,[unused],fixed symbol length status,fixed symbol length,[unused],codeword collection> Single Image 0 = Single Image 1 = Multiple Image
EZ Match User Manual