Page 111

Calibration

Disabled When this feature is disabled, the Window of Interest is not modified after the calibration process is complete.

Row and Column If the calibration process is successful, the Window of Interest will be modified to frame the symbol as well as an additional margin area around the symbol, determined by the WOI Margin parameter. Refer to the diagram below:

Column If the calibration process is successful, the Window of Interest columns will be modified to vertically frame the symbol, plus an additional margin area around the symbol, determined by the WOI Margin parameter. Refer to the diagram below:

Row If the calibration process is successful, the Window of Interest rows will be modified to horizontally frame the symbol, plus an additional margin area around the symbol, determined by the WOI Margin parameter. Refer to the diagram below:

EZ Match User Manual

5-7

Page 112

Calibration Options

Straight Line This feature is intended for use with linear symbologies. If the calibration process is successful, the orientation of the symbol is determined and the Window of Interest is modified according to the symbol orientation. The scan line orientation is determined to be vertical if the symbol tilt is between 225° and 315°, or between 45° and 135°. Otherwise, the scan line will be horizontal. If the symbol is vertical, the image column size will be set by the scan height parameter, and will be configured for full row resolution. If the symbol is horizontal, the image row size will be set by the scan height parameter, and will be configured for full column resolution. The scan line will be centered in the middle of the symbol. If the symbol is tilted such that the scan line will not pass completely through the symbol, the scan width will be adjusted to include the entire symbol. Refer to the diagram below:

Straight Line Framed This parameter is the same as “Straight Line”, except that the Window of Interest will also frame the scan line on the symbol length as well. The scan line includes the symbol plus an additional margin area determined by the WOI Margin parameter.

5-8

EZ Match User Manual

Page 113

Calibration

Window of Interest (WOI) Margin Definition: Serial Cmd: Default: Options:

Sets the margin size that is applied to the calibrated symbol. This parameter is expressed in number of pixels. If the margin causes the image to exceed the maximum image size, it will be reduced accordingly. <K529,gain,shutter speed,symbol type,WOI framing,WOI margin,line scan height,processing> 75 (pixels) 20 to 1280

Line Scan Height Definition: Serial Cmd: Default: Options:

This parameter is only used with the Straight Line modes. It sets the scan height of the straight-line image, and it is expressed in number of pixels. <K529,gain,shutter speed,symbol type,WOI framing,WOI margin,line scan height,processing> 64 (pixels) 3 to 1024

Processing Definition: Serial Cmd: Default: Options:

This setting defines the amount of time and effort the imager will spend attempting to decode a symbol for each parameter configuration. <K529,gain,shutter speed,symbol type,WOI framing,WOI margin,line scan height,processing> Medium 0 = Low 1 = Medium 2 = High 3 = Definable

Low The imager will spend a low amount of effort attempting to decode the given symbol for each parameter configuration.

Medium The imager will spend a medium amount of effort attempting to decode the given symbol for each parameter configuration.

High The imager will spend a high amount of effort attempting to decode the given symbol for each parameter configuration.

Definable The processing time for each image frame is defined by the Image Processing Timeout parameter <K245>. EZ Match User Manual

5-9

Page 114

Calibration by ESP

Calibration by ESP ESP’s Calibration view incorporates all the functionality of the <K529> (Calibration Options) command in a single easy-to-use, intuitive interface. This calibration process allows the user much finer control of individual parameters than the calibration routine in EZ Mode or on the Video tab.

Before / During Calibration Before and After tabs give the user an authentic representation of the difference in what the imager “sees” before and after the calibration routine.

Focus, Shutter, Gain, and Image Quality values are all tracked in real-time during the calibration process. Gain and Shutter Speed are configurable in the Calibration interface.

Determines the amount of time and effort the imager will spend attempting to decode a symbol for each parameter configuration. (Low, Medium, High, Definable).

Dropdown menu of 1D and 2D symbologies, and a check box for enabling or disabling Composite symbologies.

Initiates the calibration routine. Cancels the calibration process, if necessary.

The Window of Interest section of the Calibration interface allows the user to make precise adjustments to WOI Framing, WOI Margin (in pixels), and the scan height of the straight-line image (in pixels).

5-10

EZ Match User Manual

Page 115

Calibration

After Calibration Notice the improved image resolution after the calibration process is complete. The Focus, Shutter, Gain, and Quality indicator bars remain stationary at the end of calibration to provide a visual reference for the final values of these four parameters.

The calibration progress bar indicates that the process has been completed.

Saves the optimal configuration parameters determined by calibration results.

EZ Match User Manual

5-11

Page 116

Initiating Calibration

Initiating Calibration Calibration can be initiated by serial command, the EZ Button, or from the Calibration interface in ESP. In ESP, the Calibrate button starts the calibration routine.

To initiate calibration by serial command, enter the serial command<@CAL> from a terminal, such as ESP’s Terminal interface. <@CAL> is a calibration routine that emphasizes contrast and readability.

See Calibrate by EZ Button on page 1-11 for the EZ Button calibration procedure.

5-12

EZ Match User Manual

Page 117

Calibration

Calibration Progress Indicators

During the calibration process, the imager has a number of ways to communicate its progress to the user. The following three types of feedback are the primary ways that the imager communicates calibration progress.

Read Rate LEDs When calibration is initiated through a serial command or the EZ Button, the imager’s Read Rate LEDs indicate calibration progress as follows: LEDs 20% 20%, 40%, 60% 20%, 40%, 60%, 80% 20%, 40%, 60%, 80%, 100%

Calibration Progress Search Pass in progress. Medium Pass in progress. Fine-Tune Pass in progress. Calibrated Successfully (holds for green flash duration).

Calibrated Successfully Fine-Tune Pass Medium Pass

Search Pass

Beeper / Green Flash The beeper and green LED flash are used to indicate calibration status as shown in the table below: Indicator 2 quick beeps 5 quick beeps 1 long beep 1 sec. Green Flash

EZ Match User Manual

Status Calibration has started. Calibration has failed. Calibration has been completed successfully. Calibration has been completed successfully.

5-13

Page 118

Initiating Calibration

Calibration Progress Output to Terminal

When initiated by serial command or EZ Button, the calibration operation will output progress and process information to a terminal if the system is configured to do so.

Terminal Depending upon how the calibration options are configured, the calibration process can have up to 5 steps (Search Pass, Medium Pass, Fine-Tune Pass). Calibration data is shown in a simple table format under 8 category headings, each of which are defined below. Heading Prog Rating Decode Quality Shutter Gain Locate

Definition Progress indicator with a range of 0 - 100. Indicates percent complete. Rating indicator; higher ratings are more favorable. Number of successful decodes for the pass. Quality indicator; higher ratings are more favorable. Shutter setting under operation. Gain setting under operation. Time required to locate symbol, expressed in milliseconds.

Calibration Progress Output Examples (Terminal) Search Pass

The purpose of Search Pass is to decode a symbol in as few configurations as possible during calibration. This process is designed to identify symbology type, and to identify any other image processing parameters that are already calibrated. Running Search Pass

5-14

Prog

Rating

Decode

Quality

Focus

Shutter

Gain

Locate

12 14 16 18

0 0 0 2174

0 0 0 1

0 0 0 72

313 313 313 313

250 250 250 250

0 9 18 27

0 0 0 24

EZ Match User Manual

Page 119

Calibration

Medium Pass

The theory behind Medium Pass is to develop a readable range from which to dial in a decoded symbol. Running Medium Pass Prog

Rating

Decode

Quality

Focus

Shutter

Gain

Locate

51 53 55 57 59 61 63 65 67 69 71 73 75

4216 8436 6336 8448 8456 8464 8472 8488 8504 8512 8528 8584 8644

2 4 3 4 4 4 4 4 4 4 4 4 4

8 20 24 32 40 48 56 72 88 96 112 168 228

386 386 386 386 386 386 386 386 386 386 386 386 386

250 250 250 250 250 250 250 250 250 250 250 250 250

0 4 8 12 16 20 24 28 32 36 40 44 48

5 4 4 4 5 4 5 5 5 5 6 5 5

Rating List (Best): Rating = 8606; Focus = 386; Shutter = 250; Gain = 48 Rating = 8581; Focus = 386; Shutter = 250; Gain = 44 Rating = 8553; Focus = 386; Shutter = 250; Gain = 40 Rating = 8527; Focus = 386; Shutter = 250; Gain = 36 Rating = 8505; Focus = 386; Shutter = 250; Gain = 32 Rating = 8488; Focus = 386; Shutter = 250; Gain = 28 Rating = 8476; Focus = 386; Shutter = 250; Gain = 24

EZ Match User Manual

5-15

Page 120

Initiating Calibration

Fine-Tune Pass

The theory behind Fine-Tune Pass is to dial in a decoded symbol based on the range supplied by the Medium Pass. Running Fine Tune Pass Prog

Rating

Decode

Quality

Focus

Shutter

Gain

Locate

77 79 81 84 86 88 90 93 95 97 100

6416 6424 6424 6432 6448 6464 6476 6488 6506 6524 6538

3 3 3 3 3 3 3 3 3 3 3

104 112 112 120 136 152 164 176 194 212 226

386 386 386 386 386 386 386 386 386 386 386

250 250 250 250 250 250 250 250 250 250 250

38 39 40 41 42 43 44 45 46 47 48

7 6 6 6 5 5 5 5 6 5 6

Rating List (Best): Rating = 6527; Focus = 386; Shutter = 250; Gain = 48 Rating = 6517; Focus = 386; Shutter = 250; Gain = 47 Rating = 6505; Focus = 386; Shutter = 250; Gain = 46 Rating = 6491; Focus = 386; Shutter = 250; Gain = 45 Rating = 6476; Focus = 386; Shutter = 250; Gain = 44 Rating = 6462; Focus = 386; Shutter = 250; Gain = 43 Rating = 6449; Focus = 386; Shutter = 250; Gain = 42 Calibration PASSED.

5-16

EZ Match User Manual