The text of a manual · part 25 of 44
EZ Match Imager User Manual, pages 241 to 250
Pages 241 to 250 of 431
The original document is the PDF (3.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan EZ Match
Page 241
I/O Parameters
Image Mode Definition: Serial Cmd: Default: Options:
Determines which read cycle condition triggers image file output. <K757,status,comm port,image mode,image format,JPEG quality,object info output,grade output,color> Disabled 0 = Disabled 1 = Good Read 2 = No Read 3 = No Read and Good Read 4 = Mismatch
Good Read Outputs the first Good Read image in the read cycle. The image file will immediately follow the symbol data.
No Read Outputs the first No Read image in the read cycle. The image file will immediately follow the symbol data. Note: If two symbols are present in the same image capture and one of them is successfully decoded, no image will be output.
No Read and Good Read Outputs the first No Read or Good Read image in the read cycle.
Mismatch Outputs the image of the first mismatch condition.
EZ Match User Manual
8-57
Page 242
EZ Trax Output
Image Format Definition: Serial Cmd: Default: Options:
Selects the format of the image output file. <K757,status,comm port,image mode,image format,JPEG quality,object info output,grade output,color> Compressed 0 = Lossless 1 = Compressed
Lossless A “lossless” image is one that is in a high resolution format, and that will not lose resolution even when manipulated and saved multiple times. When Lossless is enabled, the JPEG Quality setting has no effect.
Compressed Outputs the image in JPEG format. Image quality is determined by the JPEG Quality setting.
JPEG Quality Definition:
Serial Cmd: Default: Options:
Sets the amount of JPEG image compression. A value of 1 represents the highest compression and lowest image quality, and 100 represents the lowest compression and highest image quality. <K757,status,comm port,image mode,image format,JPEG quality,object info output,grade output,color> 90 1 to 100 (percent)
Object Info Output Definition: Serial Cmd: Default: Options:
If a symbol is decoded during an image capture, the symbol type and other supplementary symbol information is also included. <K757,status,comm port,image mode,image format,JPEG quality,object info output,grade output,color> Disabled 0 = Disabled 1 = Enabled
Grade Output Definition: Serial Cmd: Default: Options: 8-58
Symbol quality information will be output in the form of an abbreviated identifier for each read cycle. <K757,status,comm port,image mode,image format,JPEG quality,object info output,grade output,color> Disabled 0 = Disabled 1 = Enabled EZ Match User Manual
Page 243
I/O Parameters
Color Definition: Serial Cmd: Default: Options:
The imager will generate and send a color image. <K757,status,comm port,image mode,image format,JPEG quality,object info output,grade output,color> Disabled 0 = Disabled 1 = Enabled
EZ Match User Manual
8-59
Page 244
EZ Trax Output
8-60
EZ Match User Manual
Page 245
9 Symbol Quality Contents Symbol Quality by ESP................................................................................................................. 9-2 Symbol Quality Serial Commands ................................................................................................ 9-3 Overview of Symbol Quality.......................................................................................................... 9-4 Symbol Quality Separator / Data Matrix Output Mode.................................................................. 9-5 ISO/IEC 16022 Symbol Quality Output......................................................................................... 9-7 ISO/IEC 16022 Symbol Quality Output by ESP............................................................................ 9-9 Microscan Symbol Quality Output .............................................................................................. 9-10 Microscan Symbol Quality Output by ESP ................................................................................. 9-13
This section describes how to configure and format symbol quality evaluation parameters.
EZ Match User Manual
9-1
Page 246
Symbol Quality by ESP
Symbol Quality by ESP
Click the Parameters button and then the Symbol Quality tab.
To open nested options, single-click the +.
To change a setting, double-click the setting and use your cursor to scroll through the options.
9-2
EZ Match User Manual
Page 247
Symbol Quality
Symbol Quality Serial Commands Symbol Quality Separator/ Data <K708,symbol quality separator,data matrix output mode> Matrix Output Mode ISO/IEC 16022 Symbol Quality <K709,symbol contrast,print growth,axial non-uniformity, unused ECC> Output <K710,percent cell damage,total read time,capture Microscan Symbol Quality Output time,locate time,decode time,pixels per element,ECC level,matrix size,quiet zone,symbol angle>
EZ Match User Manual
9-3
Page 248
Overview of Symbol Quality
Overview of Symbol Quality Information about symbol quality and timing can be appended to symbol data by enabling specific evaluation parameters. The order in which these values are appended corresponds directly to the order in which they appear in ESP‘s Symbol Quality tree control. Symbol Quality parameters are separated into ISO/IEC 16022 Symbol Quality Output and Microscan Symbol Quality Output. Total Read Time, Symbol Quality Separator, and Output Mode are common to both ISO/IEC 16022 and Microscan Grading Parameters.
The enabled Symbol Quality parameters are appended to symbol data output in the order that they appear in the tree control.
If you enable the outputs shown above, they will be returned in this order: Symbol Data
Locate Time (Microscan Grading)
Symbol Contrast (ISO/IEC 16022)
Decode Time (Microscan Grading)
0123456789abcdefghijklmnopqrstuv 256 A 30 210 3 17 Total Read Time
Pixels Per Element (Microscan Grading)
Capture Time (Microscan Grading)
9-4
EZ Match User Manual
Page 249
Symbol Quality
Symbol Quality Separator / Data Matrix Output Mode Symbol Quality Separator applies to both Symbol Quality groups: ISO/IEC 16022 Symbol Quality Output and Microscan Symbol Quality Output.
Symbol Quality Separator Definition: Serial Cmd: Default: Options:
Inserts a separator between each enabled field of the symbol quality output. <K708,symbol quality separator,output mode> <SP> (space character) Any ASCII character.
Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K708h,3C> For >: <K708h,3E> For , : <K708h,2C> See ASCII Character Entry Modifier on page 4-33 for a detailed explanation of how to enter ASCII characters as hex values.
Symbol Quality Separator by ESP
When you double-click on the default separator SP, the Symbol Quality Separator Calculator appears. Use the calculator keypad for one-click separator configuration.
EZ Match User Manual
9-5
Page 250
Symbol Quality Separator / Data Matrix Output Mode
Data Matrix Output Mode Note: Output Mode applies to ISO/IEC 16022 symbol quality parameters. Definition: Serial Cmd: Default: Options:
Output Mode specifies how the four output parameters, if enabled, are formatted. <K708,symbol quality separator,output mode> Grade 0 = Grade 1 = Value
Grade If in Grade Mode, a grade (A,B,C,D) is appended to the symbol data.
Value If in Value Mode, the calculated value for the given parameter is appended to the symbol data.
9-6
EZ Match User Manual