Page 81

Communications

Transparent Mode Usage: Definition:

A common application, in conjunction with handheld imagers, is one that employs an auxiliary readout to detect misapplied symbols. In Transparent Mode, data is passed between the auxiliary port and the host. The imager buffers data from the auxiliary port and echoes the keyed data on the auxiliary port. • Auxiliary port data is passed through to the host whenever a return key is pressed at the auxiliary port or whenever symbol data is sent. If sent with symbol data, it is processed on a first-in/first-out basis. • Auxiliary port data to the host is always sent with a preamble and postamble. • If the imager is in a polling mode with the host, auxiliary port data will still pass through.

Aux. Port

Host

Imager

Data Originating from the Imager

• Transmission to the auxiliary port occurs immediately upon a Good Read. • Data sent to the auxiliary port does not include a preamble or a postamble. • Communications with the auxiliary port is always in Point-to-Point protocol, even if the host is in a polled protocol mode.

Aux. Port

Host

Imager

Data Originating from the Host

• All host data is echoed to the auxiliary port in unpolled mode.

Aux. Port

Host

Imager

Serial Cmd: Options:

<K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain i.d. status,daisy chain i.d.> 1 = Transparent

EZ Match User Manual

4-13

Page 82

Auxiliary Port Connections

Half Duplex Mode Usage: Definition:

Useful when the user wants symbol data displayed on an auxiliary menu close to the imager. In Half Duplex Mode all auxiliary port data and symbol data is sent directly to the host. Symbol data is displayed on the auxiliary port menu at the same time the data is sent to the host.

Data Originating from the Auxiliary Port • Auxiliary port data to the host is ignored if the imager is in a polled mode. • Auxiliary port data or read data is sent to the host whenever it is received. • Auxiliary port data is not echoed. • Auxiliary port data to the host is always sent without a preamble or postamble.

Aux. Port

Host

Imager

Data Originating from the Imager

• Data is transmitted to the auxiliary port at the same time it is transmitted to the host. • Data transmission conforms with all parameters specified in the configuration menu (e.g. Preamble, Postamble, End of Read Cycle).

Aux. Port

Host

Imager

Data Originating from the Host

• All host data is echoed to the auxiliary port in unpolled mode.

Aux. Port

Host

Imager

Serial Cmd. Options:

4-14

<K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain i.d. status,daisy chain i.d.> 2 = Half Duplex

EZ Match User Manual

Page 83

Communications

Full Duplex Mode Usage: Definition:

When communication to and from the auxiliary port is required. In Full Duplex Mode all auxiliary port data and symbol data is sent directly to the host. Symbol data is not displayed on the auxiliary port menu.

Data Originating from the Auxiliary Port

• Auxiliary port data to the host is ignored if the imager is in a polled mode. • Auxiliary port data or read data is sent to the host whenever it is received. • Auxiliary port data is not echoed. • Auxiliary port data to the host is always sent without a preamble or postamble.

Aux. Port

Host

Imager

Data Originating from the Imager

• Data is not sent to the auxiliary port.

Aux. Port

Host

Imager

Data Originating from the Host

• All host data is echoed to the auxiliary port in unpolled mode.

Aux. Port

Host

Imager

Serial Cmd: Options:

<K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain i.d. status,daisy chain i.d.> 3 = Full Duplex

EZ Match User Manual

4-15

Page 84

Auxiliary Port Connections

Daisy Chain Mode Usage:

Definition:

Serial Cmd: Options: Function:

Useful in applications where: • More than one symbol type is present. • A symbol may be present on multiple sides of a package. • Symbols are presented at different depths. In a daisy chain application, readers are connected in tandem or a “daisy chain” and decoded data is relayed from one reader to another until the data reaches the host. A primary reader has its host port linked to the host computer and its auxiliary port linked to the host port of the first secondary reader in the chain. Thereafter, each secondary reader’s auxiliary port is linked to the host port of the secondary reader that is farther from the host in the daisy chain. Each reader in the chain can be assigned an ID that accompanies any data that it sends. <K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain i.d. status,daisy chain i.d.> 4 = Daisy Chain Before the primary reader times out, it checks its auxiliary port for data. It should be set to wait at least 30 ms for each secondary reader in the daisy chain. If no data is received within the read cycle timeout, the primary reader sends a No Read message to the host. Otherwise the complete data is sent. If, for example, the primary reader is set to timeout in 120 ms, the first secondary reader reader downstream might be set to 90 ms, the next to 30 ms, and so forth, thus assuring that at least 30 ms elapses between transmissions.a Daisy-chained readers can send a series of symbols by enablingMultisymbol and a common multisymbol separator. If the primary reader does not receive the expected number of symbols, No Read messages are appended to the data string to make up the difference between the number of symbols enabled in Multisymbol and the number of symbols read. For example, a primary and two secondary readers have Number of Symbols set to 3 and Multisymbol Separator defined as %. If the primary and the first secondary reader do not find symbols, but the next secondary reader registers a Good Read, the transmitted results would be: symbol data % No Read % No Read a. The above example assumes a best-case scenario. Other factors, such as baud rate, number of characters in a given symbol, and the number of secondary readers in the daisy chain can affect timing and may need to be included in your calculations for complete accuracy.

4-16

EZ Match User Manual

Page 85

Communications

Command Processing Mode Usage: Definition:

Serial Cmd: Options:

Allows a user to send configuration settings from the host port to the auxiliary port. When enabled, Command Processing Mode allows commands to be entered via the auxiliary port and direct externally triggered read cycle data in one of two ways: • Symbol data, including the serial trigger (if used), will be transmitted to the last port from which a command was sent. • If the last command came from the host port, then externally triggered read cycle data will only be output to the host port. <K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain i.d. status,daisy chain i.d.> 5 = Command Processing

EZ Match User Manual

4-17

Page 86

Daisy Chain ID Status Usage: Definition: Serial Cmd: Default: Options:

Used in a daisy chain setup in cases where the host needs to know which reader in the chain sent the data. Each reader in a daisy chain can be assigned a one or two character ID that will appear in front of decoded data and identify its source. <K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain i.d. status, daisy chain i.d.> Disabled 0 = Disabled 1 = Enabled

Note: Enable/disable and length must be the same in all readers.

Daisy Chain ID Usage: Definition: Serial Cmd: Default: Options:

Used in a daisy chain setup in cases where the host needs to know which reader in the chain sent the data. A one or two character prefix which identifies the particular daisy chain reader from which the data is being sent to the host. <K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain i.d. status,daisy chain i.d.> 1/ Any one or two ASCII characters.

Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K101h,,,,,,,3C> For >: <K101h,,,,,,,3E> For , : <K101h,,,,,,,2C> See ASCII Character Entry Modifier on page 4-33 for a detailed explanation of how to enter ASCII characters as hex values.

4-18

EZ Match User Manual

Page 87

Communications

Auxiliary Port System Data Status Definition: Serial Cmd: Default: Options:

When enabled, system data will be routed to the Auxiliary Port. This includes decoded data and diagnostic warning messages. When disabled, system data will not be routed to the Auxiliary Port. <K146,aux port system data status> Disabled 0 = Disabled 1 = Enabled

EZ Match User Manual

4-19

Page 88

Daisy Chain Autoconfigure

Daisy Chain Autoconfigure Usage: Definition:

Serial Cmd:

For quick setup and configuration of your daisy chain network. The command to autoconfigure the daisy chain is sent to the primary imager and the software responds in the following ways: • Counts the number of secondary readers in the daisy chain. • Assigns an internal ID number (1...n) to each secondary reader, where the first secondary reader is number 1 (the primary reader’s ID being a 0). • Propagates the communications settings and the relevant operating modes of the primary imager to the host and auxiliary ports of each secondary reader. • Resets each secondary reader. • Confirms that each secondary reader has acquired the new settings. <K150DAISY>

Note: All secondary readers must be set to Serial for Daisy Chain to function. When setting up a daisy chain operation, perform the following steps: 1. Set the primary imager (the one connected to the host) to Serial. This sets all the imagers in the chain to Serial when the command is executed. Before Autoconfigure you must set the primary imager to Serial (S): Host

S

Primary Imager

S

Secondary Imager

S

Secondary Imager

2. Send <K150DAISY>. 3. If necessary, set the primary imager to Edge. After Autoconfigure you may set the primary imager to Edge (S), but the other imagers must remain in Serial (S): Host

E

4-20

Primary Imager

S

Secondary Imager

S

Secondary Imager

EZ Match User Manual

Page 89

Communications

Response Timeout Usage:

Definition: Serial Cmd: Default: Options:

Only used when a response is required from the host. While in Multidrop, if the imager does not receive an ACK or NAK from the host after sending polled data, it will act on a fault. The reader can be set to wait indefinitely by setting Response Timeout to zero. The time that the imager will wait before timing out if ACK, NAK, and ETX are enabled, and a host response is expected. <K143,response timeout> 12 (in 1ms increments) 0 to 255 (A zero (0) setting causes an indefinite wait.)

Note: See USB HID Interface on page 4-24 for protocol information relating to USB.

EZ Match User Manual

4-21

Page 90

LRC Status

LRC Status (Longitudinal Redundancy Check) Usage: Definition:

Serial Cmd: Default: Options:

4-22

Used when extra data integrity is required. An error-checking routine that verifies the accuracy of transmissions. It is the exclusive OR of all characters following the STX (start of text) up to and including the ETX (end of text). What this means is that the binary representation of all the characters in a transmission are cumulatively added in a column and each resulting odd integer is assigned a 1 and each even integer a 0 (two 1s = 0, two 0s = 0, a 1 and a 0 = 1). The extra LRC character is then appended to the transmission, and the receiver (usually the host) performs the same addition and compares the results. <K145,status> Disabled 0 = Disabled 1 = Enabled

EZ Match User Manual