For the Microscan EZ Match

Page 221

I/O Parameters

ISO/IEC 16022 Symbol Quality Output 1 Note: Output On under Output 1 Parameters must be set to Symbol Quality (as shown below) for this output to function.

Under Output 1 Parameters, expand the Symbol Quality (ISO/IEC 16022) line.

Output on Symbol Contrast Usage: Definition: Serial Cmd: Default: Options:

Lets the user know if symbol quality is less than acceptable. If enabled, toggles Output 1 to an active state when Symbol Contrast Threshold is met. <K800,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity,axial non-uniformity threshold,output on unused ECC,unused ECC threshold> Disabled 0 = Disabled 1 = Enabled

Output on Print Growth Usage: Definition: Serial Cmd: Default: Options:

Lets the user know if symbol quality is less than acceptable. If enabled, toggles Output 1 to an active state when Print Growth Threshold is met. <K800,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity,axial non-uniformity threshold,output on unused ECC,unused ECC threshold> Disabled 0 = Disabled 1 = Enabled

EZ Match User Manual

8-37

Page 222

ISO/IEC 16022 Symbol Quality Output 1

Output on Axial Non-Uniformity Usage: Definition: Serial Cmd: Default: Options:

Lets the user know if symbol quality is less than acceptable. If enabled, toggles Output 1 to an active state when Axial Non-Uniformity Threshold is met. <K800,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity,axial non-uniformity threshold,output on unused ECC,unused ECC threshold> Disabled 0 = Disabled 1 = Enabled

Output on Unused Error Correction Usage: Definition: Serial Cmd: Default: Options:

Lets the user know if symbol quality is less than acceptable. If enabled, toggles Output 1 to an active state when Unused ECC Threshold is met. <K800,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity,axial non-uniformity threshold,output on unused ECC,unused ECC threshold> Disabled 0 = Disabled 1 = Enabled

Symbol Contrast Threshold Usage: Definition: Serial Cmd: Default: Options:

8-38

Lets the user set the acceptable level of symbol quality. Conforms to ISO/IEC 16022 symbol quality grading (A,B,C,D). <K800,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity,axial non-uniformity threshold,output on unused ECC,unused ECC threshold> Grade C 0 = Grade A 1 = Grade B 2 = Grade C 3 = Grade D

EZ Match User Manual

Page 223

I/O Parameters

Print Growth Threshold Usage: Definition: Serial Cmd: Default: Options:

Lets the user set the acceptable level of symbol quality. Conforms to ISO/IEC 16022 symbol quality grading (A,B,C,D). <K800,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity,axial non-uniformity threshold,output on unused ECC,unused ECC threshold> Grade C 0 = Grade A 1 = Grade B 2 = Grade C 3 = Grade D

Axial Non-Uniformity Threshold Usage: Definition: Serial Cmd: Default: Options:

Lets the user set the acceptable level of symbol quality. Conforms to ISO/IEC 16022 symbol quality grading (A,B,C,D). <K800,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity,axial non-uniformity threshold,output on unused ECC,unused ECC threshold> Grade C 0 = Grade A 1 = Grade B 2 = Grade C 3 = Grade D

Unused Error Correction Threshold Usage: Definition: Serial Cmd: Default: Options:

Lets the user set the acceptable level of symbol quality. Conforms to ISO/IEC 16022 symbol quality grading (A,B,C,D). <K800,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity,axial non-uniformity threshold,output on unused ECC,unused ECC threshold> Grade C 0 = Grade A 1 = Grade B 2 = Grade C 3 = Grade D

EZ Match User Manual

8-39

Page 224

Diagnostics Output 1

Diagnostics Output 1 Note: Output On under Output 1 Parameters must be set to Diagnostic Warning (as shown below) for this output to function.

Under Output 1 Parameters, expand the Diagnostics line.

Serial Cmd: Default: Options:

<K790,unused 1,service unit> 0 0 = Disabled

Service Unit When Diagnostic Warning is enabled, the Output On configuration has no effect. The output will remain active as long as one of the diagnostic warning conditions is met. The output will become inactive once it detects that there are no diagnostic warning conditions. Definition:

Serial Cmd: Default: Options:

8-40

Allows the user to set up the output to toggle to active when the service timer has expired. This condition will only be held for one service timer click. Note: This feature cannot be used if the imager is in a Continuous Read mode. <K790,unused 1,service unit> 0 0 = Disabled 1 = Enabled

EZ Match User Manual

Page 225

I/O Parameters

Tube/Cap Detection Output 1 Note: Output On under Output 1 Parameters must be set to Tube/Cap Detection (as shown below) for this output to function.

Under Output 1 Parameters, expand the Tube/Cap Detection line. Important: The Tube/Cap Detection Output 1 default setting for Output On is Presence.

Output # 1 2 3

Mode 1 = Cap Detection 1 = Cap Detection 1 = Cap Detection

Output On Presence Unknown Absence

Detection Mode Definition: Serial Cmd: Default: Options:

Detection Mode determines the type of operation to be evaluated by the imager. <K860,mode,output on> Cap Detection 0 = Tube Detection 1 = Cap Detection

Tube Detection Output On fields will show Tube Detection results.

Cap Detection Output On fields will show Cap Detection results.

EZ Match User Manual

8-41

Page 226

Tube/Cap Detection Output 1

Output On Definition: Serial Cmd: Default: Options:

Output On selects the type of condition in which to output. <K860,mode,output on> Presence 0 = Presence 1 = Absence 2 = Unknown*

*Important: There is no “Unknown” condition for Tube Detection. “Unknown” is not a valid selection for Output On if Detection Mode is set to Tube Detection.

Presence Based on the mode selected (Tube Detection or Cap Detection), the output will be asserted if the read cycle results in a Presence condition.

Absence Based on the mode selected (Tube Detection or Cap Detection), the output will be asserted if the read cycle results in an Absence condition.

Unknown Since there is no “Tube Unknown” condition, the output will be asserted if the read cycle results in an Absence condition and if the Tube/Cap Detection mode is set to Tube Detection. If Tube/Cap Detection mode is set to Cap Detection, the Unknown condition will output normally.

8-42

EZ Match User Manual

Page 227

I/O Parameters

Configurable Output 2 Note: Output 2 has the same parameters and default settings as Output 1.

Serial Cmd:

<K811,output on,output state,pulse width,output mode>

Trend Analysis Output 2 Note: Output On under Output 2 Parameters must be set to Trend Analysis (as shown below) for this output to function.

Serial Cmd:

<K781,trend analysis mode,trigger evaluation period,number to output on,decodes/trigger threshold>

ISO/IEC 16022 Symbol Quality Output 2 Note: Output On under Output 2 Parameters must be set to Symbol Quality (as shown below) for this output to function.

Serial Cmd:

<K801,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity,axial non-uniformity threshold,output on unused ECC,unused ECC threshold>

Diagnostics Output 2 Note: Output On under Output 2 Parameters must be set to Diagnostic Warning (as shown below) for this output to function.

Serial Cmd:

<K791,unused 1,service unit>

EZ Match User Manual

8-43

Page 228

Tube/Cap Detection Output 2

Tube/Cap Detection Output 2 Note: Output On under Output 2 Parameters must be set to Tube/Cap Detection (as shown below) for this output to function.

Serial Cmd:

<K861,mode,output on>

Under Output 2 Parameters, expand the Tube/Cap Detection line. Important: The Tube/Cap Detection Output 2 default setting for Output On is Unknown.

Presence Based on the mode selected (Tube Detection or Cap Detection), the output will be asserted if the read cycle results in a Presence condition.

Absence Based on the mode selected (Tube Detection or Cap Detection), the output will be asserted if the read cycle results in an Absence condition.

Unknown Since there is no “Tube Unknown” condition, the output will be asserted if the read cycle results in an Absence condition and if the Tube/Cap Detection mode is set to Tube Detection. If Tube/Cap Detection mode is set to Cap Detection, the Unknown condition will output normally.

8-44

EZ Match User Manual

Page 229

I/O Parameters

Configurable Output 3 Note: Output 3 has the same parameters and default settings as Output 1 and Output 2.

Serial Cmd:

<K812,output on,output state,pulse width,output mode>

Trend Analysis Output 3 Note: Output On under Output 3 Parameters must be set to Trend Analysis (as shown below) for this output to function.

Serial Cmd:

<K782,trend analysis mode,trigger evaluation period,number to output on,decodes/trigger threshold>

ISO/IEC 16022 Symbol Quality Output 3 Note: Output On under Output 3 Parameters must be set to Symbol Quality (as shown below) for this output to function.

Serial Cmd:

<K802,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity,axial non- uniformity threshold,output on unused ECC,unused ECC threshold>

Diagnostics Output 3 Note: Output On under Output 3 Parameters must be set to Diagnostic Warning (as shown below) for this output to function.

Serial Cmd:

<K792,unused 1,service unit>

EZ Match User Manual

8-45

Page 230

Tube/Cap Detection Output 3

Tube/Cap Detection Output 3 Note: Output On under Output 3 Parameters must be set to Tube/Cap Detection (as shown below) for this output to function.

Serial Cmd:

<K862,mode,output on>

Under Output 3 Parameters, expand the Tube/Cap Detection line. Important: The Tube/Cap Detection Output 3 default setting for Output On is Absence.

Presence Based on the mode selected (Tube Detection or Cap Detection), the output will be asserted if the read cycle results in a Presence condition.

Absence Based on the mode selected (Tube Detection or Cap Detection), the output will be asserted if the read cycle results in an Absence condition.

Unknown Since there is no “Tube Unknown” condition, the output will be asserted if the read cycle results in an Absence condition and if the Tube/Cap Detection mode is set to Tube Detection. If Tube/Cap Detection mode is set to Cap Detection, the Unknown condition will output normally.

8-46