Page 381

Appendices Tube/Cap Detection Output 3 Symbol Quality Symbol Quality Separator/ Data Matrix Output Mode ISO/IEC 16022 Symbol Quality Output Microscan Symbol Quality Output

<K862,mode,output on> <K708,symbol quality separator,data matrix output mode> <K709,symbol contrast,print growth,axial non-uniformity,unused ECC> <K710,percent cell damage,total read time,capture time,locate time,decode time,pixels per element,ECC level,matrix size,quiet zone,symbol angle>

Matchcode Matchcode Type Number of Master Symbols New Master Pin Enter Master Symbol Data Request Master Symbol Data Delete Master Symbol Data Match Replace Mismatch Replace Camera and IP Setup IP Timeout IP Threshold Mirrored Image Window of Interest Hollow Mode Number of Symbols in Field of View Damaged Symbol Focal Distance (Read-Only) Focal Distance Table (Read-Only) IP Mode Tube/Cap Mode Illumination Brightness Skew Correction Camera Parameters Pixel Sub-Sampling Color Filter (EZ Match Color Only) Color Detection (EZ Match Color Only) IP Database Number of Active Indexes

EZ Match User Manual

<K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on No Read,sequence on mismatch> <K224,number of master symbols> <K225,status> <K231,master symbol number,master symbol data> <K231?,>[for all] or <K231?,master symbol number> <K231,master symbol number,> <K735,status,match replacement string> <K736,status,mismatch replacement string> <K245,image processing timeout> <K512,threshold mode,fixed threshold value,cycle min,cycle max,cycle step,adaptive contrast percent> <K514,mirrored image> <K516,row pointer,column pointer,row depth,column width> <K517,hollow mode status> <K518,number of symbols in field of view> <K519,damaged symbol status> <K525,focal distance> <K526,number of focal distances,focal distance> <K527,IP Mode,FLM direction> <K533,tube/cap direction,tube/cap rotation,cap unknown qualify, tube/cap presence before output,cap unknown presence before output> <K536,brightness> <K537,line speed,symbol direction> <K541,shutter speed,gain> <K542,sub-sampling> <K543,color filter> <K544,status,color match resolution> <K252,number of active database settings>

A-11

Page 382

Serial Configuration Commands IP Database Status Save Current Settings to Database Load Current Settings from Database Request Selected Index Settings Request All Database Settings Database Mode Output Format Format Extract Format Insert Format Assign Format Status Output Filter Configuration Ordered Output Filter

A-12

<K255,index,shutter speed,gain,sub-sampling,row pointer,column pointer,row depth, column width,threshold mode,fixed threshold value,processing mode, narrow margins, background color,symbology type> <K255+,index> <K255-,index> <K255?,index> <K255?> <K256,switch mode,frame count/time,image process looping,image dimensions> <K740,output index,start location,length> <K741,output index,length,hex string> <K742,symbol number,status> <K743,output format status> <K744,filter number,symbology type,length,wildcard, placeholder, data,unused,database index> <K745,number of filters>

EZ Match User Manual

Page 383

Appendices

Serial Command Format

Serial commands are of two types: utility and configuration.

Rules that apply to both utility and configuration commands • A less than < and greater than > character enclose the commands. • Commands and data are “case sensitive.” That is, characters must be entered as upper or lower case, as specified.

Serial Utility Commands These are sent during operations and are not followed by <A> or <Z>.

Serial Configuration “K” Commands These begin with a single “K” character followed by a 3-digit numeric character, data fields, and an initializing command, as follows: <Knumeric parameter,data,data,...etc.><initializing command> An initializing command <A> or <Z> may follow the command. A <Z> initializes the imager’s memory and saves for power-on; an <A> initializes the imager’s memory but does not save for power-on. For example, to enable UPC and save the change for power-on, send <K473,1><Z>. To change Baud Rate and reset without saving changes for power-on, send <K100,3><A>.

Serial Configuration Command Conventions

• All data fields (except the last) must be followed by a comma (without a space). • NUL cannot be used. The characters <, >, and , can be used, but only if entered as hex pairs (see ASCII Character Entry Modifier on page 4-33). • All fields preceding a modified field must be included. • If there is no change in preceding fields, then commas alone can be entered in these fields. For example, if only the last field in the following command is changing, <K100,4,1,0,0> can be entered as <K100,,,,0>. • All fields following a modified field can be omitted. For example, to change Baud Rate only, send <K100,3>.

EZ Match User Manual

A-13

Page 384

Serial Configuration Commands

Concatenating Configuration Commands Commands can be concatenated (added together) in a single string or data block. For example, <K145,1><K220,1><K450,1><A> enables LRC, sets End of Read Cycle mode to New Trigger, enables Narrow Margins, and resets the data buffers (without saving the changes for power-on).

Serial Command Status Request To ensure that any command was received and accepted, you can send the Show Reader Status command: <?>. The status of a specific serial command can be requested by entering the command followed by a question mark. For example, send <K142?> to request the status of Postamble.

Entering Control Characters in Serial Commands To enter control characters within a serial command, hold down the Ctrl key while typing the desired character. Example: To enter a carriage return and line feed (^M^J), enter <K141,1,CNTL-m CNTL-j>

A-14

EZ Match User Manual

Page 385

Appendices

Appendix D, Communications Protocol Communications Protocol Command Table Protocol Command (Mnemonic displayed on menu)

Control Characters (Entered in menu or serial command)

Hex Value

Effect of Command

RES

^D

04

Reset

REQ

^E

05

Request

EOT

^D

04

Reset

STX

^B

02

Start of Text

ETX

^C

03

End of Text

ACK

^F

06

Acknowledge

NAK

^U

15

Negative Acknowledge

XON

^Q

11

Begin Transmission

XOFF

^S

13

Stop Transmission

EZ Match User Manual

A-15

Page 386

Communications Protocol

ACK / NAK Data Flow Examples Setup 1 RES REQ STX ETX ACK NAK LRC

0x00 (disabled) 0x00 (disabled) 0x00 (disabled) 0x00 (disabled) 0x06 0x15 disabled

Transfer 1 HOST_TX IMAGER_TX

<K141,0> ‘ACK’

Transfer 2 HOST_TX IMAGER_TX IMAGER_TX HOST_TX

<K141?> ‘ACK’ <K141,0> ‘ACK’

Error Condition Transfer 1 IMAGER_TX HOST_TX IMAGER_TX HOST_TX symbol data ‘NAK’ (host rejects) symbol data (resend data) ‘ACK’ (transaction complete)

Transfer 2 HOST_TX <K141?> IMAGER_TX ‘ACK’ IMAGER_TX <K141,0> timeout reached... timeout reached... timeout reached... Timeout Reached transaction aborted, data is flushed

A-16

EZ Match User Manual

Page 387

Appendices

Setup 2 RES REQ STX ETX ACK NAK LRC

0x00 (disabled) 0x00 (disabled) 0x00 (disabled) 0x00 (disabled) 0x06 0x15 enabled

Transfer 1 HOST_TX IMAGER_TX

<K141,0>a ‘ACK’

Transfer 2 HOST_TX IMAGER_TX IMAGER_TX HOST_TX

<K141?>B ‘ACK’ <K141,0>a ‘ACK’

Error Condition Transfer 1 HOST_TX IMAGER_TX HOST_TX IMAGER_TX

EZ Match User Manual

<k141,0>x (BAD LRC) ‘NAK’ <K141,0>a (GOOD LRC) ‘ACK’

A-17

Page 388

Communications Protocol

Setup 3 RES REQ STX ETX ACK NAK LRC

0x00 (disabled) 0x00 (disabled) 0x28 ‘(‘ 0x29 ‘)’ 0x06 0x15 enabled

Transfer 1 HOST_TX IMAGER_TX

(<K141,0>)H ‘ACK’

Transfer 2 HOST_TX IMAGER_TX IMAGER_TX HOST_TX

A-18

(<K141?>)k ‘ACK’ (<K141,^M>)w ‘ACK’

EZ Match User Manual

Page 389

Appendices

Setup 4 RES REQ STX ETX ACK NAK LRC

0x21 ‘!’ 0x3D ‘=’ 0x28 ‘(‘ 0x29 ‘)’ 0x06 0x15 enabled

Transfer 1 HOST_TX IMAGER_TX

(<K141,0>)H ‘ACK’

Transfer 2 HOST_TX IMAGER_TX HOST_TX IMAGER_TX HOST_TX IMAGER_TX

(<K100?>)n ‘ACK’ ‘!’ (<K100,8,0,0,1>)X ‘ACK’ ‘!’

Error Condition Transfer 1 HOST_TX (<K141,0>)H IMAGER_TX ‘ACK’ HOST_TX (<K100?>)n IMAGER_TX ‘ACK’ HOST_TX ‘!’ IMAGER_TX (<K100,8,0,0,1>)X timeout reached... IMAGER_TX ‘=’ timeout reached... IMAGER_TX ‘=’ timeout reached... IMAGER_TX ‘=’ timeout reached... IMAGER_TX ‘!’

EZ Match User Manual

A-19

Page 390

Communications Protocol

Polling Mode Data Flow Examples Setup 1 Address RES REQ STX ETX ACK NAK LRC

0x01 (translates to) Poll Req @ ‘0x1C’, Unit Select @ ‘0x1D’ 0x04 0x05 0x02 0x03 0x06 0x15 disabled

Transfer 1 HOST_TX IMAGER_TX HOST_TX IMAGER_TX HOST_TX

‘RES’ ‘0x1D’ ‘REQ’ (Select Unit 1 to receive data) ‘0x1D’ ‘ACK’ (Unit responds with its address) ‘STX’ <T> ‘ETX’ ‘0x1D’ ‘ACK’ (Unit responds with its address) ‘RES’ (Terminate Transfer 2)

Transfer 2 HOST_TX IMAGER_TX HOST_TX IMAGER_TX

‘RES’ ‘0x1C’ ‘REQ’ (Poll Unit 1 for data) ‘0x1C’ ‘STX’ <T/00000> ‘ETX’ ‘ACK’ ‘RES’ (Terminate Transfer 1)

Starting with a ‘RES’ ensures a clean transaction, without “leftovers” from the previous transaction.

Error Condition 1 HOST_TX ‘RES’ ‘0x1C’ ‘REQ’ (Poll Unit 1 for data) IMAGER_TX ‘0x1C’ ‘STX’ <T/00000> ‘ETX’ HOST_TX ‘Nothing’ (Host should ‘ACK’ here) timeout reached... IMAGER_TX ‘REQ’ (Unit requests an ‘ACK’ again) timeout reached... IMAGER_TX ‘REQ’ (Unit requests an ‘ACK’ again) timeout reached... IMAGER_TX ‘REQ’ (Unit requests an ‘ACK’ again) timeout reached... IMAGER_TX ‘RES’ (Terminate Transfer 1, data is flushed)

A-20

EZ Match User Manual