One-page Microscan configuration sheet for the EZ Match imager. It shows four basic setups (USB at 5V, stand-alone at 10-28V, stand-alone with an MS-Connect 210 box, and daisy chain) and lists the part numbers of the imager, power supplies, interface boxes, sensors and cables used in them.
- Imager
- EZ Match, part number FIS-0004-100XG; 1-megapixel B&W, 3-megapixel color option p. 1
- Setups
- USB (5V); Stand-Alone (10-28V); Stand-Alone with MS-Connect 210 (10-28V); Daisy Chain (10-28V) p. 1
- 5V power supply
- 97-000002-02: 90-264 VAC in, +5VDC out p. 1
- 24V power supply
- 97-100004-15: 90-264 VAC in, 24VDC out, USA/Euro plug p. 1
- Voltage converter
- IC-332 (FIS-0001-0035G), voltage converter to 10-28V p. 1
- Interface box
- IB-131, part number 99-000018-01 p. 1
- Connectivity box
- MS-Connect 210, part number FIS-0210-000XG p. 1
- Object detectors
- Visible NPN photo sensors: 99-000017-01 (Dark On), 99-000017-02 (Light On), 99-000019-01 (Light On) p. 1
- USB breakout cable
- 61-000151-01: USB breakout cable with flying leads, 3 ft p. 1
- Communication cable
- 61-300026-03: 25-pin plug to 9-pin socket p. 1
- Reader cable
- 61-000127-01: EZ Match to MS-Connect 210, 6 ft p. 1
- Host cable
- 61-000105-01: MS-Connect 210 to host, user-stripped to 9-pin p. 1
- Daisy chain cable
- 61-100029-03: IB-131 to IB-131, 1 ft p. 1
- Sheet part number
- P/N 83-200044 Rev C p. 1
What this manual walks you through
- Connecting one EZ Match directly to a host computer by USB p. 1
- Setting up one EZ Match stand-alone on 10-28 volts p. 1
- Setting up an EZ Match with an MS-Connect 210 connectivity box p. 1
- Linking several imagers in a daisy chain to one host p. 1
Questions this manual answers
What is the part number of the Microscan EZ Match imager?
FIS-0004-100XG, a 1-megapixel black and white imager with a 3-megapixel color option. p. 1
How are several EZ Match imagers connected together?
In a daisy chain: a primary imager links to the host, secondary imagers send their data through it, and IB-131 boxes are joined with cable 61-100029-03. p. 1
What cable connects an EZ Match to an MS-Connect 210?
Reader cable 61-000127-01, 6 ft long. p. 1
What power supplies are listed for the EZ Match setups?
Power supply 97-000002-02 (90-264 VAC, +5VDC) and power supply 97-100004-15 (90-264 VAC, 24VDC, USA/Euro plug). p. 1
The file
Size and text
Every page · 1
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 1
Open in the PDF
The text of page 1, from the PDF itself
EZ Match - CONFIGURATION USB (5V)
This is the basic setup for a single USB EZ Match Imager. The EZ Match is connected directly to a host computer.
Stand-Alone (10-28V) System Matrix
To 5V trigger or stripped cable (eight flying leads). Default Output 1 Output 2 Output 3 Trigger +5VDC Ground New Master
System Matrix Product
Part Number
This is the basic 10-28-volt setup for a single EZ Match Imager.
ProductPart NumberDescription(1) EZ MatchFIS-0004-100XG
1-Megapixel B&W or 3-Megapixel Color option available
(2) IC-332
FIS-0001-0035G
Voltage converter (to 10-28V)
(3) IB-13199-000018-01Interface Box(4) Power Supply97-100004-15
90-264 VAC, 24VDC, USA/Euro plug
(5) Object Detector
99-000017-01
Photo Sensor, Visible, NPN, Dark On
(6) Communication Cable
61-300026-03
25-pin plug to 9-pin socket
Description
(1) EZ Match
FIS-0004-100XG 1-Megapixel B&W or 3-Megapixel Color option available
(2) Power Supply97-000002-0290-264 VAC, +5VDC
(3) Object Detector (optional)
99-000019-01
Photo Sensor, Visible, NPN, Light On
(4) Breakout Cable
61-000151-01
Cable, USB, Breakout, Flying Leads, 3 ft.
Stand-Alone with MS-Connect 210 (10-28V) This is the basic setup for a single EZ Match Imager and an MS-Connect 210 Connectivity Box.
Daisy Chain (10-28V) A primary imager is linked directly to the host. Secondary imagers are linked in tandem. Data is sent from each secondary imager to the primary imager, and from the primary imager to the host.
System MatrixSystem MatrixProductPart NumberDescriptionProductPart NumberDescription(1) EZ MatchFIS-0004-100XG
1-Megapixel B&W or 3-Megapixel Color option available
(1) EZ Match
FIS-0004-100XG
1-Megapixel B&W or 3-Megapixel Color option available
(2) IC-332
FIS-0001-0035G
Voltage converter (to 10-28V)
(2) MS-Connect 210FIS-0210-000XGConnectivity Box(3) IB-13199-000018-01Interface Box(3) IC-332FIS-0001-0035G
Voltage converter (to 10-28V)
(4) Power Supply
97-100004-15
90-264 VAC, 24VDC, USA/Euro plug
(4) Reader Cable
61-000127-01
EZ Match to MS-Connect 210 cable, 6 ft.
(5) Object Detector
99-000017-01
Photo Sensor, Visible, NPN, Dark On
(5) Power Supply
97-100004-15
90-264 VAC, 24VDC, USA/Euro plug
(6) Daisy Chain Cable
61-100029-03
IB-131 to IB-131, 1 ft.
(6) Object Detector
99-000017-02
Photo Sensor, Visible, NPN, Light On
(7) Communication Cable
61-300026-03
25-pin plug to 9-pin socket
(7) Host Cable
61-000105-01
MS-Connect 210 to host, user-stripped to 9-pin (included)
Copyright ©2015 Microscan Systems, Inc. Specifications subject to change. P/N 83-200044 Rev C