Page 1 of CiMAX 75xxA/76xx Scanner Technical Reference Manual

Manual · Sick

CiMAX 75xxA/76xx Scanner Technical Reference Manual

Manual206 pagesPDF 3.4 MB

Technical reference manual for the CiMAX 7500A, 7550A, 7555A, 7600, 7650 and 7655 fixed-position laser barcode scanners.

Download the PDF3.4 MB

Covers · 10 models

The models it covers

Summary

What is in it

Technical reference manual for the CiMAX 75xxA/76xx family of intelligent fixed-position laser scanners (7500A, 7550A, 7555A, 7600, 7650 and 7655) and their Basic, Standard and Hex Interface Units. It gives specifications, installation and site preparation steps, photoeye and tachometer mounting, controls, connectors and indicators, an introduction to barcode scanning and scan tunnels, startup and operation, host commands and downloads, communication modes and diagnostics, plus setup strings, an ASCII table and dimension diagrams.

Its parts

  1. Overview & Maintenance
  2. Installation & Setup
  3. Controls, Connectors, & Indicators
  4. Introduction to Scanning
  5. Startup & Operation
  6. Host Commands & Downloads
  7. Communication Modes
  8. Diagnostics

From the manual

Key facts from this manual

Each line names its page in the PDF.

The Rev F (February 2002) SICK Auto Ident technical reference manual for the CiMAX 75xxA/76xx fixed-position laser scanners: the 7500A, 7550A, 7555A, 7600, 7650 and 7655. It gives the specifications, installation planning, connectors and status lights of the scanners and of the Basic, Standard and Hex Interface Units, then startup, host commands and diagnostic tests.

Read for this summary: pages 1 to 3, 23 to 31, 33 to 35, 41 to 46, 89 to 90, 106 and 141 to 142 of 206.

Device
Fixed-position laser scanner for high read rates, with a DSP plus a 32-bit main processor and user C programming p. 24
Ports
Host port (RS-232 or RS-422), Terminal port (RS-232), RS-485 Starnode LAN port; network port optional on 75xxA only p. 28
Power
Regulated +12 VDC, 1.2 A max from the Basic Interface Unit; or +12 VDC 1.0 A and +5 VDC 250 mA from the Standard/Hex Interface Unit p. 27
Memory
256K (about 100K for user C programs and data) or 1M (about 800K) p. 26
Scan rate
400 to 1200 scans per second at a 60 degree scan angle, depending on the application p. 27
Laser
Laser diodes, 670 nanometers, visible red p. 27
Depth of field
Fixed focus at 4, 8, 14, 18, 26.5, 28 or 36 inches p. 26
Inputs and outputs
15 inputs (8 standard, 7 optional for height sensing), active low under 1.0 VDC; 8 open-collector outputs, 30 VDC at 150 mA max p. 28
Operating range
32 to 122 F (0 to 50 C); humidity 5% to 95% non-condensing p. 27
Size, 7500A and 7600
7500A: 5.71 x 4.33 x 4.55 in, 3.5 lb; 7600: 5.71 x 3.32 x 4.55 in, 3.0 lb p. 26, 27
Size, side-exit models
7550A/7555A: 5.70 x 4.78 x 6.85 in, 4.0 lb; 7650/7655: 5.71 x 3.32 x 6.08 in, 3.5 lb p. 27
Network option
75xxA only: Ethernet 10 base 2 or 10 base T, SDS, or DeviceNet; not offered on the 7600 p. 24, 26
Standard Interface Unit
115/230 VAC; 8 inputs, 8 outputs, optional Opto-22 style AC I/O modules, one Form C relay; powers one scanner, or two in Master/Slave p. 24, 29, 30
Enclosure
Gasketed aluminum enclosure on an aluminum base plate; the manual states NEMA 12 (IP 65), dust-tight and drip-proof p. 27

What this manual walks you through

  • Planning the installation and preparing the site p. 33, 34, 35
  • Monthly cleaning and inspection of the scanner p. 31
  • Reading the six status LEDs on the scanner p. 41, 42
  • Wiring the Basic Interface Unit I/O panel and DB-15 scanner connector p. 43, 44
  • Connecting a host PC to the Basic Interface Unit p. 45
  • Wiring AC power to the Standard Interface Unit p. 46
  • Powering up and reading the startup messages on the Setup port p. 89, 90
  • Requesting the 17-character status string from a host p. 106
  • Testing the motor speed and the eight inputs and outputs p. 141, 142

Good to know

  • Internal parts need no preventive maintenance; opening the scanner with power applied can expose electrical and mechanical hazards. p. 31
  • The Basic Interface Unit supplies +12 VDC only and is meant for a scanner without the Ethernet option. p. 43
  • The SETUP connector inside the Standard Interface Unit does not work with the CiMAX 1400 hand-held terminal. p. 46
  • If the motor does not reach a stable speed within one minute, the scanner runs without turning the laser on. p. 90
  • The setup follows a site keysheet; the manual says not to change the configuration without consulting SICK Auto Ident. p. 25

Questions this manual answers

What power does the CiMAX 7600 scanner need?

Regulated +12 VDC at 1.2 A max from the Basic Interface Unit, or +12 VDC at 1.0 A and +5 VDC at 250 mA from the Standard or Hex Interface Unit. p. 27

What is the difference between the CiMAX 7600 and the 7500A?

They work the same, but the 7600 has no network option and its case is an inch narrower (3.32 in against 4.33 in). p. 24

How does the CiMAX 7555A or 7655 scan?

It sweeps a horizontal beam back and forth in a sinusoidal sweep raster for more coverage, in the same housing as the 7550A/7650. p. 25

What are the DB-15 pins on the CiMAX Basic Interface Unit?

Pin 2 Host RXD, pin 3 Host TXD, pin 4 Output 1, pin 6 presence input, pin 7 signal ground, pin 8 frame ground, pin 9 +12 VDC at 1.2 A. p. 44

How do I read the CiMAX scanner status from a host?

Send the ASCII 5 command; the scanner returns its software version and a 17-character status string, whose last position flags a laser diode failure. p. 106

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. CiMAX 75xxA/76xx Scanner Technical Reference Manual1
  2. Warning!3
  3. CHAPTER 1 Overview & Maintenance23
    1. Overview23
    2. Specifications26
    3. Maintenance31
  4. CHAPTER 2 Installation & Setup33
    1. Unpacking & Inspection33
    2. Installation Checklist33
    3. Site Preparation36
  5. CHAPTER 3 Controls, Connectors, & Indicators41
    1. Scanner41
    2. Interface Units42
  6. CHAPTER 4 Introduction to Scanning65
    1. Introduction65
    2. Reading Barcodes65
    3. Introduction to Scan Tunnel Applications85
  7. CHAPTER 5 Startup & Operation89
    1. Serial Communications Ports89
    2. CiMenu32 for Windows Utility (Optional)100
  8. CHAPTER 6 Host Commands & Downloads103
    1. Introduction103
    2. Control Commands from the Host103
    3. C Program Control Commands125
    4. C Programming Considerations126
    5. Data Detection by C131
  9. CHAPTER 7 Communication Modes133
    1. OPMODE Parameter133
    2. Scale Mode134
    3. Starnode Usage134
    4. RS-422 Mode134
  10. CHAPTER 8 Diagnostics135
    1. Introduction135
    2. Gap Tracking Diagnostics156
    3. CIX Troubleshooting168
  11. APPENDIX A Group Setup Strings173
    1. Group Setup String Definitions173
    2. Group Setup Parameter String Formats174
  12. APPENDIX B ASCII Equivalence187
15 more lines, from page 187 on
  1. ASCII Equivalence Table187
  2. APPENDIX C Dimension Diagrams191
    1. CiMAX 7500A Scanner191
    2. CiMAX 7555A Scanner192
    3. CiMAX 7600 Scanner193
    4. CiMAX 7650/7655 Scanner194
    5. Standard Interface Unit195
    6. Hex Interface Unit196
    7. Basic Interface Unit197
    8. Photoeye197
    9. Photoeye Tree Bracket199
    10. Photoeye Tree Hardware200
    11. Tachometer Assembly201
    12. CiMAX 1400 Hand-Held Terminal202
  3. Index203

From the PDF’s own bookmarks.

The whole text · 23 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 61-6
  2. Contents, pages 7 to 147-14
  3. Contents, pages 15 to 2215-22
  4. CHAPTER 1 Overview & Maintenance23-32
  5. CHAPTER 2 Installation & Setup33-40
  6. CHAPTER 3 Controls, Connectors, & Indicators, pages 41 to 4841-48
  7. CHAPTER 3 Controls, Connectors, & Indicators, pages 49 to 5649-56
  8. CHAPTER 3 Controls, Connectors, & Indicators, pages 57 to 6457-64
  9. CHAPTER 4 Introduction to Scanning, pages 65 to 7265-72
  10. CHAPTER 4 Introduction to Scanning, pages 73 to 8073-80
  11. CHAPTER 4 Introduction to Scanning, pages 81 to 8881-88
  12. CHAPTER 5 Startup & Operation89-102
  13. CHAPTER 6 Host Commands & Downloads, pages 103 to 112103-112
  14. CHAPTER 6 Host Commands & Downloads, pages 113 to 122113-122
  15. CHAPTER 6 Host Commands & Downloads, pages 123 to 132123-132
  16. Pages 133 to 142133-142
  17. Pages 143 to 152143-152
  18. Pages 153 to 162153-162
  19. Pages 163 to 172163-172
  20. APPENDIX A Group Setup Strings173-186
  21. APPENDIX B ASCII Equivalence187-190
  22. APPENDIX C Dimension Diagrams191-202
  23. Index203-206

The file

Revision and size

Part no.EM-63165-1F
RevisionRev F, February 2002
PublisherSICK Auto Ident, Inc.
Pages206
PDF3.4 MB