The text of a manual · part 6 of 23
CiMAX 75xxA/76xx Scanner Technical Reference Manual: CHAPTER 3 Controls, Connectors, & Indicators, pages 41 to 48
Pages 41 to 48 of 206, from CiMAX 75xxA/76xx Scanner Technical Reference Manual
The original document is the PDF (3.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the RVSI CiMatrix 7500, RVSI CiMatrix 7555A, Sick 7555A, RVSI CiMatrix 7600, RVSI CiMatrix 7655, Siemens 7500, Siemens 7555A, Sick 7600, and 2 more models
Page 41
3 Controls, Connectors, & Indicators
CHAPTER 3
This chapter describes the physical layout, controls, connectors and indicators on the CiMAX 75xxA/76xx Scanner, the Basic Interface Unit, Standard Interface Unit, and the Hex Interface Unit.
Scanner LED Display There are six status indicators on the rear panel of the CiMAX 75xxA/76xx Scanner, as shown in Figure 3–1. FIGURE 3–1. LED Display
Setup
Presence yellow
Decode
XMIT/RCV
I/O green
Rev F, February 2002
PWR/Laser ON
CiMAX 75xxA/76xx Scanner Technical Reference Manual
3-1
Controls, Connectors, & Indicators
3
Page 42
Chapter
3
Controls, Connectors, & Indicators
Setup The SETUP LED indicates that the scanner is in either the Setup or Diagnostics mode rather than in the normal operating mode. When this LED is On, the CiMAX 75xxA/76xx Scanner is not running application software.
Presence The PRESENCE LED shows the status of the scan zone presence detect photoeyes. If the scanner is configured to use presence, the LED lights when an object is in the scan zone.
Decode The DECODE LED lights when the scanner is decoding a barcode.
Xmit/Rcv The XMIT/RCV LED will blink whenever the scanner is sending or receiving data. This includes messages to and from all sources that are sent via the Host, Setup and Starnode ports. The Ethernet port is not monitored. This LED helps to verify correct wiring and confirms that the scanner is receiving communications from any source.
I/O The I/O LED shows the state of all inputs and outputs (1 through 8) combined. That is, if any of the inputs or outputs are activated, this LED will be on. To view the status of each input or output, the user must run the Inputs/Outputs test of the Diagnostics Program. The user may also observe which relays are active in the Interface Unit.
Pwr/Laser On (green) This LED indicates that power to the scanner is On. When power is first applied to the scanner, the scanning motor starts and the on-board computer performs internal diagnostics. After the diagnostics tests are completed, the laser is turned on and normal operation begins.
Interface Units Basic Interface Unit The Basic Interface Unit allows you to make I/O and relay connections at a more convenient location than at the scanner itself. The scanner is connected directly to the 15-pin D-type connector on the Basic Interface Unit, as shown in Figure 3–2. A two-meter cable is provided with the interface for this purpose.
3-2
CiMAX 75xxA/76xx Scanner Technical Reference Manual
Rev F, February 2002
Page 43
Interface Units
FIGURE 3–2. Basic Interface Unit - Block Diagram
DB-9 Starnode Setup CiMAX 7600 I/O Power, GND
DB-25 Inputs Outputs Power DB-9 Host Slave to Host computer
Basic Interface Unit DB-15 Connector
RS-232 Serial Comms
TXD, RXD, GND to relay
Output
Digital Output
AC in
PRES, +12V, GND to Presence Photoeye
The basic interface provides six screw-down I/O connections, identified by silk-screened labels on the outside of the case. The DB-15 and screw-down connectors are shown in Figure 3–3. FIGURE 3–3. Basic Interface Unit - I/O Panel SCANNER CONNECTION
SERIAL COMM.
OUTPUT
PRESENCE PHOTOEYE
. . . . . .
DB-15
GND (also used
RXD TXD OUTPUT
+12VDC for serial com ground)
PRESENCE
Note: The Basic Interface Unit provides +12VDC ±5% only and is designed for use with the optionally configured CiMAX 75xxA/76xx Scanner, without Ethernet option.
Rev F, February 2002
CiMAX 75xxA/76xx Scanner Technical Reference Manual
3-3
Controls, Connectors, & Indicators
3
Page 44
Chapter
3
Controls, Connectors, & Indicators
I/O Panel Inputs & Outputs RXD Terminal connector for RXD signal on an RS-232 communications link with Host computer.
TXD Terminal connector for TXD signal on an RS-232 communications link with Host computer.
Output Terminal connection for scanner's solid state Output 1, by default, the NO READ signal.
Presence Terminal connector for presence signal from an inzone detecting photoeye.
+12VDC Terminal connector for +12 VDC power for an inzone detecting photoeye (50 mA maximum).
GND Terminal connector for common grounds for a photoeye and the RS-232 communications link.
Scanner Connection D-type connector for scanner power, serial communications, inputs and outputs, as shown in Figure 3–4. The pins assignments of the DB-15 connector are shown in Table 3–1. FIGURE 3–4. DB-15 Connector
1
8
15
DB-15
9
TABLE 3–1. DB-15 Pin Assignments
3-4
Pin
Description
1
Not used
2
Host RXD (data from Host)
3
Host TXD (data to Host)
4
Output 1
5
Not Used
6
Presence Input
7
Signal Ground
8
Frame Ground
9
+12 VDC ±5%, 1.2A
10-15
Not Used
CiMAX 75xxA/76xx Scanner Technical Reference Manual
Rev F, February 2002
Page 45
Interface Units
Connection to a Host You can connect the Basic Interface Unit to a PC that will act as a Host. This is a three-wire connection (RXD, TXD, and GND). On a typical 25-pin RS-232 connector on a host computer, RXD is pin 2, TXD is pin 3, and GND is pin 7.
Standard Interface Unit
FIGURE 3–5. Standard Interface Unit - Interconnection Block Diagram Scanner Terminal or PC DB-9 CiMAX 7500A
STARNODE SETUP
Connect to scanner or at interface unit
DB-25 INPUTS OUTPUTS POWER DB-9 HOST SLAVE
Standard Interface Unit
J3
DB-9 SET-UP
TB 2 & 6
TB 1 relays RS-232 Host computer Presence and height photoeyes
Hex Interface Unit The Hex Interface Unit is a special box that allows more than one scanner to be used in a tunnel type application. You can have up to six scanners attached to one interface unit. This allows most of the common signals to be connected to more than one scanner without additional wiring. It also allows for a quicker and more reliable installation. Because of the specialized nature of these applications, this box must be specific to the application.
Rev F, February 2002
CiMAX 75xxA/76xx Scanner Technical Reference Manual
3-5
3
Controls, Connectors, & Indicators
The Standard Interface Unit allows you to make most CiMAX 75xxA/76xx Scanner connections at a more convenient location than at the scanner itself, which may be mounted where it is not easily accessible. The Standard Interface Unit can usually be mounted at the side of the conveyor, allowing easy access from the floor. Figure 3–5 illustrates how the scanner and the Standard Interface Unit are interconnected.
Page 46
Chapter
3
Controls, Connectors, & Indicators
Starnode drop cables can be directly connected to TB7 and TB8. These terminal blocks can be an extension of any Starnode network branch. All Starnode rules still apply in the layout of Starnode network (refer to the Starnode Installation & Site Planning Guide). This allows a common connect for the Starnode drop cables and eliminates the need for individual T-TAP boxes.
Standard Interface Connections The Standard Interface Unit is connected to the scanner by the cables provided with the system. The cables connect DC power to the scanner and all of the scanner input, output and communications signals, to the interface unit. You must connect the network cables directly to the scanner. You can connect a PC, running terminal software, to the SETUP port in the SET/STAR connector on the scanner. However, it may be more convenient to connect it to the SETUP connector inside the Standard Interface Unit. The SETUP connector in the Standard Interface Unit does not support the CiMAX 1400 HandHeld terminal.
AC Power 115/230 VAC (auto selected) ±15%, 50/60 Hz, 40 W max power is required by the Standard Interface Unit. This supplies DC power to itself, to the scanner, and provides AC voltage for relays controlling AC-operated devices. The AC Power Cable is fed into the interface through a punch-out hole in the case. The AC line connections are made at TB7, using the screws labeled NEUT and LINE. The ground wire must be connected directly to the case, as shown Figure 3–6. FIGURE 3–6. AC Power Connection
TB 7
LINE
NEUT
GROUND
CASE AC LINE IN
Toggle switch S1 on the circuit board is an AC ON/OFF switch. Because the cover of the interface will normally be closed, AC power should be supplied to the interface through an external, fused switch.
3-6
CiMAX 75xxA/76xx Scanner Technical Reference Manual
Rev F, February 2002
Page 47
Interface Units
Hex Interface Connections The Hex Interface Unit requires its own AC power. There is a 4 A 250 VAC, 3AG fuse located in the fuse compartment above the power switch. To access the fuse, open the fuse compartment with a small screwdriver.
The Hex Interface Unit provides six setup connectors, one for each scanner. In some applications, scanner A is acting as a master scanner using its host port to communicate over a sub-system RS422 multi drop connection to other scanners in the system. This master's setup port is used to communicate to a host computer using RS-232 on TB1 pins 39 and 40. If Switch 1 (S1) is in the normal position, scanner A setup port is also connected to a RS-232 to RS-422 converter. The RS-422 host connection will be made on TB9 pins 1 - 4. Switch 2 is a dipswitch that may be used to connect a number of scanners setup port receive data lines together. This may be used when data from the Programmable Interface Controller must be sent to all of the scanners. SICK Auto Ident, Inc. cable (A1-63397-1) will be connected between Programmable Interface Controller J1 and Hex Interface Box J18. Make sure that the cable end with pin 8 is connected to the Programmable Interface Controller. Switch 2 positions are as follows: •
If all scanners are to receive the same data on the Setup Port, S2 should be set (11111xxx), where: –
1=On
–
0=Off
– x= don’t care
•
Position 5 - F (BCDEFxxx) Position 5 must be set to On to connect data to any other scanners. Scanner F gets data directly from J18.
•
Scanner A requires that S1 be in the setup position to receive data.
When the CiMAX 75xxA/76xx Scanner is connected to the Hex Interface Unit, ensure the correct switch is On for that scanner. Those scanners must use the SETUP port to receive data from the Programmable Interface Controller. If you wish to use this port for setup or diagnostics, set the applicable switch to Off temporarily, during testing.
Rev F, February 2002
CiMAX 75xxA/76xx Scanner Technical Reference Manual
3-7
3
Controls, Connectors, & Indicators
If you position the Hex Interface Unit with the scanner cables exiting on your left side, scanner A is the cable closest to the slide Starnode door. The scanners are labeled A through F, with scanner F located closest to the corner of the box.
Page 48
Chapter
3
Controls, Connectors, & Indicators
FIGURE 3–7. S1 & S2 Connection Diagram
Normal S1 (A) TXD
J3-8
(A) RXD
RS-232/422 Converter
J3-7 Setup S2
J6 J9 J12 J15 J18
Scanner (B) RXD Scanner (C) RXD Scanner (D) RXD Scanner (E) RXD Scanner (F) RXD
1 2 3 4 5 6 7 8
Another use of these switches is when you wish to update the operating system of more than one scanner at the same time. If you wish to upgrade the OS, communication to a scanner must be made to that scanner’s setup port through one of the six connectors in the Hex Interface Unit. Each connector is used for each individual scanner. For example, if you have two CiMAX 75xxA Scanners or two CiMAX 76xx Scanners attached to positions C and D, connect the computer to J9 or J12. Set S1 to normal and S2 to 01100000 (0=off, 1=on).
Control Input Connections Interface Unit Inputs All standard solid state control input connections to the Interface Unit(s) are available at terminal block TB1, as shown in Figure 3–10, “Standard Interface Unit Circuit Board” on page 3-12, and Figure 3–11, “Hex Interface Unit Circuit Board” on page 3-13. Connector assignments are listed in Table 3–2, “Interface Unit I/O Connections - TB1,” on page 3-17. Eight low-voltage DC solid state control inputs are provided and are, by default, assigned to accept inzone and outzone presence, tachometer and five height sensor signals, as specified in Table 3–2, “Interface Unit I/O Connections - TB1,” on page 3-17. The assignments are shown in parentheses in the table. A custom C program or the Setup parameters may be used to override the default assignments. 3-8
CiMAX 75xxA/76xx Scanner Technical Reference Manual
Rev F, February 2002