2 Installation & Setup
2 Installation & Setup
CHAPTER 2
This chapter provides you with an overview of the CiMAX 75xxA/76xx scanner hardware installation and setup. It also describes the procedure for mounting the scanner and interconnections to the interface unit, photoeyes and tachometer.
Unpacking & Inspection Unpack the scanner and any accessories ordered. Depending on what you ordered, the equipment may have been shipped in more than one carton. Remove the packing list from the pocket on each carton. Verify that you have received all of the items shown on the packing lists. Inspect the equipment for shipping damage and, if you see any damage, notify both the carrier and SICK Auto Ident, Inc. immediately. Store the original packing material inside each carton, and store the cartons in a safe place. If the scanner or any accessories need to be repaired, upgraded or modified in the future, return them to SICK Auto Ident, Inc. in the original cartons with the original packing material. Refer to “Product Warranty” on page xix and “Return-to-Factory Instructions” on page xviii for more information.
Installation Checklist •
Plan and schedule complete installation
•
Identify and include personnel responsible for:
•
Rev F, February 2002
–
Scanning system
–
Data system
–
Control or conveyor system
–
Maintenance
–
Installation
Review plan with SICK Auto Ident, Inc. Field Service Engineer - Confirm schedule two weeks prior to engineer arriving on site for functional checkout CiMAX 75xxA/76xx Scanner Technical Reference Manual
2-1
Page 34
Chapter
2
Installation & Setup
Site Preparation Refer to the keysheet. •
Scanner
•
AC power to Interface Unit. Ensure AC power is connected to an earth ground.
•
AC power (convenience outlets) for local PC, CRT, modem, oscilloscope. Ensure AC power is connected to an earth ground.
•
Structure for mechanically installing scanner
•
Interface unit
•
Tachometer, if used, including custom mounting brackets and flexible shaft coupling for required mechanical isolation
•
Photoeyes –
Presence
–
Height-sensing, if used, including mounting brackets
•
Setup/Diagnostic Terminal - CiMAX 1400, local CRT, or PC running serial communications software program, i.e., Microsoft Windows Terminal, ProComm or Telix.
•
Telephone for support
•
Telephone line for support modem
•
Verify conveyor speeds and width
•
Verify box height variations
•
Verify label symbology, dimensions and quality
•
Verify all parts, mounting brackets, cables, connectors, and personnel available
Physical Installation •
Supporting structure for scanner with provisions for exact positioning
•
Interface Unit
•
Hex Interface Unit, if installed
•
Tachometer. brackets and shaft isolation, provided by installer, are important.
•
Photoeyes - Exact Positioning Is Critical!
•
2-2
–
Presence
–
Height-sensing
Modem
CiMAX 75xxA/76xx Scanner Technical Reference Manual
Rev F, February 2002
Page 35
Installation Checklist
Electrical Connections
•
2
To Scanner –
Network (if used)
–
I/O cable to interface unit (DC power)
Installation & Setup
•
To Interface Unit –
Grounded AC power
–
I/O cable to scanner
–
Presence photoeyes
–
Tachometer (installer provides cable)
–
Height-sensing photoeyes
–
Communication cable(s) provided by installer
–
Any special digital I/O connections
–
Modem and cables, provided by installer
On Site Testing On site testing with SICK Auto Ident, Inc. Field Service Engineer or SICK Auto Ident, Inc.Certified Installer. Plan for one day per scanner plus 1/2 day for training. •
Review operational requirements
•
Review mechanical and electrical installation
•
Functional Reading Tests –
Diagnostics
–
Read Labels -
Known good from SICK Auto Ident, Inc.
-
Customer labels
-
Field Service Diagnostic Test Kit
-
Basic Tests
-
Over extremes of label placement
•
Set or verify photoeye placement parameters
•
Run Tachometer Diagnostic - automatically sets some setup parameters
•
Verify communications and special I/O circuits –
Rev F, February 2002
To customer device CiMAX 75xxA/76xx Scanner Technical Reference Manual
2-3
Page 36
Chapter
2
Installation & Setup
–
If necessary, transmit to known good device (PC running communications software program)
–
Through modem to remote site for support
–
Ethernet, if used, directly to scanner connector
•
Test application
•
Repeat with spare equipment
Operation Instruction Instruct user personnel in operation of product. •
Manual with keysheet
•
LED Displays
•
Operation
•
Setup parameters
•
Diagnostics
•
Troubleshooting
•
Label quality
•
Communications and special I/O circuits
•
Modem
•
Selected support plan
•
Other support alternatives
Final Approval •
User/customer sign-off on installation checklist. Copy and file.
•
Update keysheet or other documentation as necessary for future reference
Site Preparation Power When installed, the Interface Unit will require a dedicated AC outlet. You should provide additional 115 VAC outlets near the Interface Unit for setup and diagnostic test equipment. +12VDC and +5VDC regulated DC power is provided by the Standard/Hex Interface Unit. +12VDC regulated DC power is provided by the Basic Interface Unit.
2-4
CiMAX 75xxA/76xx Scanner Technical Reference Manual
Rev F, February 2002
Page 37
Site Preparation
Setup In addition to the components illustrated in Figure 1–1, “Typical Configuration - CiMAX 7500A/7600” on page 1-1, you should have one of the following: CiMAX 1400 hand-held terminal
•
PC computer with terminal emulation software and cable
•
RS-232 ASCII terminal
Installation & Setup
•
2
Communications wiring to the host is necessary.
Photoeyes & Tachometer Installation Follow the installation directions only if your system requires presence photoeyes, height-detecting photoeyes and a tachometer.
Installing the Tachometer A tachometer is required to measure conveyor movement for gap tracking. Refer to “Gap Tracking” on page 4-11 for more information. Gap tracking is required when there is the possibility that more than one box may be in the scanning zone at the same time. You must provide a custom bracket to mount the tachometer securely to your conveyor. Connect the tachometer to a driven roller or other driven rotational part of your conveyor using a flexible shaft coupling or a belt and pulley drive as shown in Figure 2–1. FIGURE 2–1. Tachometer Driver by Flexible Shaft Coupling
Tachometer Housing
Shaft Coupling
Note: You must use an appropriate flexible shaft coupling or belt and pulley drive to provide mechanical isolation of the tachometer from your conveyor. Without such isolation, the tachometer is subject to misalignment, roller shaft wobble and consequent wear to the tachometer's precision bearings. Alternatively, a friction wheel can be used, to couple the tachometer to the surface of a belted conveyor. Friction drives have the potential to slip and cause tracking errors over time, but may be suitable for your application. A suitable measuring wheel (P/N 16002070215) with a 12" circumference, a white rubber surface and an inside diameter compatible with the standard SICK Auto Ident, Inc. tachometer, and a universal tracking mounting base (P/N 14005750000), can be purchased from:
Rev F, February 2002
CiMAX 75xxA/76xx Scanner Technical Reference Manual
2-5
Page 38
Chapter
2
Installation & Setup
Danaher Controls 1675 Delany Road Gurnee, IL 60031 The CiMAX 75xxA/76xx scanner requires inputs from a tachometer that produces a conveyor travel resolution finer than 0.20 inches per pulse with a pulse rate of no more than 1 kHz. Lower resolution will affect position accuracy but may provide enough accuracy for your application. The examples in Table 2–1 display conveyor travel per pulse if a 300-pulses/revolution tachometer is driven directly from conveyor rollers of the diameters indicated. The speeds listed produce 1 kHz pulse rates. TABLE 2–1. Conveyor Travel per Pulse
Roller diameter:
2 inches
3 inches
4 inches
Resolution:
0.021 inches
0.031 inches
0.042 inches
Conveyer Speed:
21 inches/sec
31 inches/sec
42 inches/sec
105 ft/min.
157.5 ft/min.
210 ft/min.
If you use higher conveyor speeds, connect the tachometer directly to a larger diameter driven roller or use a belt and pulley system to achieve slower tachometer rotation, as shown in Figure 2–2. Optionally, use a tachometer that generates fewer pulses per revolution. Figure 2–2 displays a pulley arrangement providing a speed reduction of 3 to 1 and a 33% decrease in tachometer resolution. FIGURE 2–2. Pulley Arrangement
Conveyor Conveyor Roller 1”Dia.
3”Dia.
Tach Drive Pulley
The speed reduction will be proportional to the ratio of the pulley diameters, with the tachometer connected to the larger diameter pulley. The resolution will decrease in inverse proportion to the ratio of the diameters.
Mounting Presence Photoeyes The photoeye positions for your application are specified on your keysheet.
Mounting Photoeye Tree Bracket The bracket supports the height-detecting photoeyes on one side of the conveyor. A second bracket supports reflectors for each photoeye on the other side of the conveyor. Mount the height-detecting photoeyes immediately upstream of the inzone photoeye. Dimensions of the bracket available from SICK Auto Ident, Inc. are listed in “Photoeye Tree Bracket” on page C-9.
2-6
CiMAX 75xxA/76xx Scanner Technical Reference Manual
Rev F, February 2002
Page 39
Site Preparation
Scanner Installation
Connecting CiMAX Scanner & Basic/Standard/Hex Interface Unit 1.
Remove AC power at the circuit breaker.
2.
Connect the AC power cord to line power from the Basic/Standard/Hex Interface Unit.
3.
Connect the 25-pin connector to In/Out PWR and secure it.
4.
Connect the 9-pin female connector to the Host and secure it.
5.
Verify that the Interface Unit power switch is in the Off position.
It is preferable but not necessary to use the SICK Auto Ident, Inc. Basic/Standard/Hex Interface Unit(s) with the scanner. When you use an Interface Unit, you will obtain all I/O connections, except Ethernet, at the Interface Unit. Do not attempt to connect directly to the scanner without contacting SICK Auto Ident, Inc. Inside the Standard/Hex Interface Unit, use terminal block 1 (TB1) to make low power I/O connections. Use terminal block 2 (TB2) to make connections to relays. Refer to Chapter 3, “Controls, Connectors, & Indicators” for connection information. WARNING! IF YOU ARE USING OPTO-22 MODULES FOR INPUTS AND OUTPUTS, AC VOLTAGES MAY BE PRESENT IN THE INTERFACE UNIT. YOU SHOULD MAKE SURE THAT ALL EXTERNAL POWER IS REMOVED FROM THE INTERFACE UNIT’S INPUTS AND OUTPUTS BEFORE PERFORMING ANY MAINTENANCE. THE ON-OFF SWITCH ON THE SCANNER DOES NOT CONTROL THESE VOLTAGES.
On-Off Switch SICK Auto Ident, Inc. recommends that you supply AC power, with a ground wire, to either the Interface Unit or to user-supplied DC power supplies through an external, fused control switch meeting all local electrical codes.
Rev F, February 2002
CiMAX 75xxA/76xx Scanner Technical Reference Manual
2-7
2 Installation & Setup
Mount the scanner on a supporting structure next to the conveyor such that it can be exactly positioned as detailed on your keysheet. The scanner should not be subject to shock or vibration from the conveyor.