Page 23

1 Overview & Maintenance

1 Overview & Maintenance

CHAPTER 1

This chapter provides you with an overview of a typical CiMAX 75xxA/76xx scanner application product specifications.

Overview Typical Physical Setup CiMAX 75xxA/76xx scanners may be used with other equipment including photoeyes, tachometer, Standard Interface Unit, and a Hex Interface Unit. Figure 1–1 shows the CiMAX 7500A scanner in a typical scan tunnel configuration with accessory components. However, your application may not have the same requirements. Specific cable connections, pinouts and wiring diagrams are provided in Chapter 3, “Controls, Connectors, & Indicators”. FIGURE 1–1. Typical Configuration - CiMAX 7500A/7600

B o x M o vin g o n C o n ve y o r

R e fle c to r Reflector C iM A X 7500A S c anner

Photoeye P ho to e ye (upstream of scanner)

(up s tre a m o f s c a nne r )

Inte rfa cUnit e U nit Interface

Rev F, February 2002

CiMAX 75xxA/76xx Scanner Technical Reference Manual

1-1

Page 24

Chapter

1

Overview & Maintenance

CiMAX 7500A/7600 Laser Scanner The 75xxA/76xx scanners are intelligent fixed-position laser scanners designed for high reading rates, local or network processing and control and user C programmability. Optionally, it can be configured with SICK Auto Ident, Inc. CIX (Code Information eXtraction) technology to permit barcodes rotated as much as 60° from the scan beam to be read. A network option (Ethernet, SDS, or DeviceNet) is also available with 75xxA scanners. The dual processor architecture uses an independent Digital Signal Processor (DSP), to translate barcode data for the 32-bit main processor. The CiMAX 75xxA/76xx scanners can be configured with up to 1MB of non-volatile program and data memory. The CiMAX 75xxA/76xx scanners have eight inputs and eight outputs for use in box presence and height detection, timing, diverter control, and alarming. The Standard Interface Unit provides power for one scanner; or two, when operated in Master/Slave mode. The Basic Interface Unit only provides power for one CiMAX 76xx, or one CiMAX 75xxA without the Ethernet option installed. The CiMAX 7600 scanner is operationally identical to the 7500A except that the network option is not available. The CiMAX 7600 case is an inch narrower (3.32" vs. 4.33") than that of the CiMAX 7500A, so the CiMAX 7600 can be mounted in more physically restricted spaces.

CiMAX 7550A/7650 Laser Scanner The CiMAX 7550A/7650 scanners are electrically and operationally identical to the CiMAX 7500A/7600. The housing of the CiMAX 7550A/7650 is physically longer than the CiMAX 7500A to accommodate a 90° deflection mirror, which permits the laser beam to output from the side instead of the front of the case, as shown in Figure 1–2. FIGURE 1–2. CiMAX 7650 Scan Sweep

This design allows for a flatter installation. For example, it can be installed under a conveyor to scan labels on the bottom of a box. It is sometimes used to scan picket-fence orientation barcodes or the bottom of boxes as they pass over a break in the conveyor. The cable connectors may be positioned to face up or down, and the mounting screws are located on the side of the unit.

1-2

CiMAX 75xxA/76xx Scanner Technical Reference Manual

Rev F, February 2002

Page 25

CiMAX 7555A/7655 Laser Scanner The CiMAX 7555A/7655 emits a horizontal beam that is swept back and forth in a sweep raster scanning pattern as shown in Figure 1–3. FIGURE 1–3. Sweep Raster Scan Pattern of the CiMAX 7555A/7655

Scan Height

Sweep Height

The CiMAX 7555A/7655 sweep raster scanner provides a moving, visible red laser beam that sweeps repeatedly across a barcode in a regular sinusoidal wave pattern. The CiMAX 7555A/7655 has the same housing as the CiMAX 7550A/7650, but the laser beam is deflected in a sweep raster pattern for increased coverage. Refer to Appendix C, “Dimension Diagrams” for mechanical drawings of the CiMAX 7500A, the CiMAX 7550A, the CiMAX 7600, and the CiMAX 7650/7655. Except where specifically noted, all information in this manual applies to the CiMAX 7500A/7550A/7555A/7600/7650/7655 Scanners.

Keysheet The Keysheet specifies the details of your scanner setup. It is based on information you provided to SICK Auto Ident, Inc. about your scanner application. The keysheet has been carefully developed from the results of a questionnaire you filled out about your conveyor system. The information in the keysheet customizes the CiMAX 75xxA/76xx scanner hardware and software setup for your site. Do not deviate from the keysheet or otherwise change the configuration without consulting SICK Auto Ident, Inc.

Software Updates Software updates from SICK Auto Ident, Inc. can include changes and improvements in the following: •

Rev F, February 2002

Operating System

CiMAX 75xxA/76xx Scanner Technical Reference Manual

1-3

1 Overview & Maintenance

Overview

Page 26

Chapter

1

Overview & Maintenance

•

CIX Technology

•

Network

•

File Memory

•

C code

•

Decoded Symbologies

Software updates will be provided to you by SICK Auto Ident, Inc. as your application requires. These updates can be uploaded into your scanner from your PC, with the software available from SICK Auto Ident, Inc. on a diskette. The scanner uses flash memory to allow complete re-programming in the field.

Specifications Scanner Configuration Depth of Field (DOF)/Diodes •

Fixed focus: 4”, 8”, 14”, 18”, 26.5”, 28”, 36”

Memory •

256K (approx. 100K for user C programs and data)

•

1M (approx. 800K for user C programs and data)

Network - 75xxA only •

Without

•

Ethernet 10 base 2

•

Ethernet 10 base T

•

SDS

•

DeviceNet

Physical For mechanical drawings with dimensions, refer to Appendix C, “Dimension Diagrams”.

CiMAX 7500A

1-4

•

5.71 x 4.33 x 4.55 inches (145 x 110 x 115 mm)

•

3.5 pounds (1.6 kilograms)

CiMAX 75xxA/76xx Scanner Technical Reference Manual

Rev F, February 2002

Page 27

CiMAX 7550A/7555A •

5.70 x 4.78 x 6.85 inches (145 x 121 x 174 mm)

•

4.0 pounds (1.8 kilograms)

CiMAX 7600 •

5.71 x 3.32 x 4.55 inches (145 x 85 x 115 mm)

•

3.0 pounds (1.4 kilograms)

CiMAX 7650/7655 •

5.71 x 3.32 x 6.08 inches (145 x 85 x 155 mm)

•

3.5 pounds (1.6 kilograms)

Method of Illumination Laser diodes, wavelength 670 nanometers (visible red light)

Scan Rates •

Application dependent - Refer to your keysheet

•

400-1200 scans per second @ 60o scan angle

Power •

Input –

Power required from external Basic Interface Unit. Regulated +12 VDC, 1.2A max.

–

Power required from Standard/Hex Interface Unit. +12 VDC, 1.0A, +5 VDC, 250 mA., max.

Construction Single integrated package consisting of aluminum enclosure fully gasketed and mounted on 1/2-inch (12.7 mm) aluminum base plate.

Environmental •

NEMA 12 (IP 65) dust-tight and drip-proof

•

Operating Temperature - 32° to 122° F. (0o to 50o C)

•

Humidity - 5% to 95% non-condensing

LED Status Indicators Six LEDs on a single display monitor operations and communications

Rev F, February 2002

CiMAX 75xxA/76xx Scanner Technical Reference Manual

1 Overview & Maintenance

Specifications

1-5

Page 28

Chapter

1

Overview & Maintenance

Communications Four independent communications ports •

1 asynchronous serial Host port (RS-232 or RS-422)

•

1 asynchronous serial Terminal port (RS-232)

•

1 RS-485 LAN port with Starnode protocol

•

1 Network port (optional) - CiMAX 75xxA only

Inputs •

Fifteen total, active low when <1.0 VDC –

•

Eight standard inputs –

– •

Maximum input 30 VDC intermittent, 27 VDC continuous

Normal default input assignments -

Two presence (Inzone, Outzone)

-

One tachometer - 0.2 inches per pulse minimum resolution at up to 1000 pulses per second, max

-

Up to five height-sensing inputs

Inputs not used for presence, tachometer and height-sensing are available for general purpose use under user C program control

Seven optional inputs - For use only for height-sensing with Programmable Interface Controller

Outputs •

Eight total, open collector solid state - 30 VDC at 150 mA, max

•

Normal default output assignments –

Output 1 - No Read

–

Output 2 - Match

–

Output 3 - No Match

Basic Interface Unit Physical Refer to Appendix C, “Dimension Diagrams” for more information.

1-6

•

3.64 H x 4.13 W x 1.39 D inches (93 x 105 x 35 mm)

•

1.6 lbs (0.73 kg) with attached cable CiMAX 75xxA/76xx Scanner Technical Reference Manual

Rev F, February 2002

Page 29

•

Scanner-interface cable length - 6.5 feet (2 meters)

•

Power cord length - 15 feet (4.6 meters)

AC Power 115/230 ±10% VAC @ 0.4/0.2A, 50/60 Hz.

Inputs Basic - One solid state, active low when <1.0 VDC, 30 VDC max, 27 VDC continuous (This input is an extension of scanner input 1, default INZONE PRESENCE signal)

Outputs •

Basic - One open collector solid state, 30 VDC at 150 mA, max. (This output is an extension of scanner output 1, default NO READ signal)

•

+12 VDC and ground to operate external photoeye

•

RS-232 serial communications link to host computer

Standard Interface Unit Physical Refer to Appendix C, “Dimension Diagrams” for more information. •

13.25 H x 13.00 W x 2.98 D inches (337 x 330 x 76 mm)

•

13.5 lbs (6.1 kg) with attached cable

•

Scanner-interface cable length - 6.5 feet (2 meters)

AC Power 115/230 ±10% VAC @ 0.8/0.4A, 50/60 Hz.

Inputs Standard - Eight solid state, active low when <1.0 VDC, 30 VDC max, 27 VDC continuous (These inputs are extensions of the eight solid state scanner inputs)

Outputs Standard - Eight open collector solid state, 30 VDC at 150 mA, max. (These outputs are extensions of the eight solid-state scanner outputs)

Optional Solid-State Input/Output Modules Optically isolated Opto–22 style modules may be installed as inputs or outputs. They are controlled by standard input/output signals. •

Input Modules –

Rev F, February 2002

Type - AC Input

CiMAX 75xxA/76xx Scanner Technical Reference Manual

1 Overview & Maintenance

Specifications

1-7

Page 30

Chapter

1

Overview & Maintenance

–

•

Voltage Range - 90-140 VAC -

6 mA at minimum voltage

-

10 mA at max. voltage

Output Modules –

Type - AC Output

–

Load Current Over Load Voltage Range - 0.02 - 3 A at 24 - 140 VAC

Electro-Mechanical Output Relay One Form C (SPDT) relay operated by scanner output eight.

Hex Interface Unit Physical For dimensions, refer to Appendix C, “Dimension Diagrams”. •

21 H x 18.5 W x 4.25 D inches (533 x 470 x 108 mm)

•

50.5 lbs (22.9 kg) with attached cable

•

Scanner-interface cable length - 6.5 feet (2 meters)

AC Power 115/230 VAC +10% @ 3.0/1.5A, 50/60 Hz.

Inputs Standard - Eight solid state, active low when <1.0 VDC, 30 VDC max, 27 VDC continuous (These inputs are extensions of the eight solid state scanner inputs)

Outputs •

Standard - Eight open collector solid state, 30 VDC at 150 mA, max. (These outputs are extensions of the eight solid-state scanner outputs).

Optional Solid-State Input/Output Modules Optically isolated Opto–22 style modules may be installed as inputs or outputs. They are controlled by standard input/output signals. •

1-8

Input Modules –

Type - AC Input

–

Voltage Range - 90-140 VAC -

6 mA at minimum voltage

-

10 mA at max. voltage

CiMAX 75xxA/76xx Scanner Technical Reference Manual

Rev F, February 2002

Page 31

•

Output Modules –

Type - AC Output

–

Load Current Over Load Voltage Range - 0.02 - 3 A at 24 - 140 VAC

Electro-Mechanical Output Relay One Form C (SPDT) relay operated by scanner output eight.

Maintenance The scanner requires no special preventive maintenance when operated in an environment free from extremes of temperature, humidity, shock, and vibration. The following tasks should be performed once a month to keep the scanner clean and to inspect it for mechanical damage. 1.

Remove DC power and disconnect all cables before cleaning.

2.

Clean dirt and dust from the scanner's window and from the LED display, using a soft, lint-free cloth and a non-abrasive liquid cleaner. DO NOT use an abrasive cleaner.

3.

Check all cables for signs of abrasion.

4.

Check that all cable connections are secure after maintenance.

Caution: The scanner's internal components do NOT require preventive maintenance. Opening the scanner with power applied can expose the operator to electrical and mechanical hazards, which can cause bodily injury. If internal maintenance is required, return the scanner to SICK Auto Ident, Inc. for service.

Rev F, February 2002

CiMAX 75xxA/76xx Scanner Technical Reference Manual

1 Overview & Maintenance

Maintenance

1-9

Page 32

Chapter

1-10

1

Overview & Maintenance

CiMAX 75xxA/76xx Scanner Technical Reference Manual

Rev F, February 2002