Page 173
A Group Setup Strings
A Group Setup Strings
APPENDIX A
This appendix defines the group setup strings that are used to set up the scanner from a host computer. Each string is diagrammed to identify the parameters in the string by their positions. Not all strings apply to all scanners.
Group Setup String Definitions TABLE A–1. Group Setup String Definitions
Region X
Group Y
Parameter
Parameters in Setup String
0
0
SCANNER OPERATION
000-003, 012, 014
0
1
GENERAL DECODING
004-010, 015
0
2
HISTOGRAM
016-018, 056-059
0
3
DECODE FORMAT
020-027
0
4
DECODE FORMAT
028-035
0
5
MATCH STRINGS
040-047
0
6
MATCH STRINGS
048-055
0
7
DSP PARAMETERS
060-069
0
8
DSP PARAMETERS
070-079
0
9
AUTO SETUP
080-095
1
0
HOST SERIAL PORT
100-114
2
0
TERM SERIAL PORT
200-210
4
0
LAN PORT COMMS and MSGS
400-403
4
1
ETHERNET PARAMETERS
405-408,413-414 (75A only)
4
2
ETHERNET PARAMETERS
409-412, 415 (75A only)
4
4
MOTOR SPEED
444
4
5
LASER 1 PROGRAMMABLE POTS
450-459
4
9
JUMPER SETTINGS
495
Rev F, February 2002
CiMAX 75xxA/76xx Scanner Technical Reference Manual
A-1
Page 174
Appendix
A
Group Setup Strings
TABLE A–1. Group Setup String Definitions (continued)
Region X
Group Y
Parameter
Parameters in Setup String
5
0
PRESENCE INPUTS, RELAY TYPES
501,503-506,510-518
5
2
RELAY OUTPUTS
541-543, 553-560
6
0
USER PROGRAM
600-601
6
1
USER VARIABLES
610-625
7
0
GAP TRACKING and TACH
700-709, 726-731
7
1
HEIGHT DETECT
710-719, 725, 732, 733, 743, 744
The region and group number make up the two digit number used in the upload and download commands, as illustrated in Table A–1. A leading 8 invokes an upload command, to set (change) one or more parameter values. A leading 9 invokes a download command, to permit parameter values to be reviewed. When the user wants to download a group of parameters for review, the command ?9XY should be used, where: 9 = get parameters X = 0 through 8 for the general region Y = 0 through 9 for the particular group string in that region.
When the user wants to upload many parameters at once to set or modify their values, as when loading values according to a keysheet, the command ?8XY should be used, where: 8 = set parameters X = 0 through 8 for the general region Y = 0 through 9 for the particular string.
When the user wants to set an individual parameter, the command?XXX should be used, where: XXX = the three-digit parameter number.
Group Setup Parameter String Formats Spaces between characters are for illustration only. Spaces are not used in actual strings, except for the space after the ?nnn number or where otherwise indicated. The default values for parameters are shown in these strings. Your application may require other parameter values. Note: The scanner will reboot automatically when you exit the Setup menu so the newly entered values will take effect.
A-2
CiMAX 75xxA/76xx Scanner Technical Reference Manual
Rev F, February 2002
Page 175
A Group Setup Strings
Group Setup Parameter String Formats
Scanner Operation Parameters Parameters 000-003, 012, 014 (?800) ?800
2
0
0
000
0
001 normal mode report port (add: 1, 2, 16, 64, 128, 256) normal mode report format (0, 1, 2, 3, 4)
iomode (add: 1, 2, 16, 64, 128) opmode (0–Normal, 1–reserved, 2–Master, 3–Slave, 4–Passthru) reserved termdevice (0–Handheld, 1–reserved, 2–Dumb)
General Decoding Parameters Parameters 004-010, 015 (?801) ?801 04 32
01
04
00
0
0000
10
0000 fixed quiet zone mirror count reserved clock rate rd qual thr null count val thresh max label min label
Histogram Parameters Parameters 016-018, 056-059 (?802) ?802
1
0
0
063
044
035 000 box report multiple read character separator character no read character C128 FNC1 character translation no histogram ties histogram weight string (1, 2, or 3 digits, with leading spaces entered if less than three digits entered)
Rev F, February 2002
CiMAX 75xxA/76xx Scanner Technical Reference Manual
A-3
Page 176
Appendix
A
Group Setup Strings
Decode Format Parameters Parameters 020-027 (?803) ?803 SSMMLLASCCC SSMMLLASCCC SSMMLLASCCC SSMMLLASCCC SSMMLLASCCC SSMMLLASCCC SSMMLLASCCC SSMMLLASCCC Parameters 028-035 (?804) ?804 SSMMLLASCCC SSMMLLASCCC SSMMLLASCCC SSMMLLASCCC SSMMLLASCCC SSMMLLASCCC SSMMLLASCCC SSMMLLASCCC
SSMMLLASCCC first two label characters data separator character (default ; ) also send, 00 - No data is added to the barcode for this decode format bin +01 - Add number of decodes label length +02 - Add Read Quality +04 - Add Symbology when to send label data +08 - Add Processor decoded label +16 - Reserved symbology +32 - Append the data instead of prepending the data
Note: The spaces are used as delimiters between the decode formats.
Example The default settings are: ?803 10020000; 20020000; 50020600; 00000000; 00000000; 00000000; 00000000; 00000000; ?804 00000000; 00000000; 00000000; 00000000; 00000000; 00000000; 00000000; 00000000;
Note: CC field values are not entered in the default settings.
Match Strings Parameters Parameters 040-047 (?805) ?805 each string of eight parameters may have a maximum of 60 alphanumeric characters. The total string must be less than 255 characters (127 over Starnode). If a match string is not being used, a NONE should be entered in the string, as illustrated below. NONE NONE NONE NONE NONE NONE NONE NONE Parameters 048-055 (?806)
A-4
CiMAX 75xxA/76xx Scanner Technical Reference Manual
Rev F, February 2002
Page 177
?806 each string of eight parameters may have a maximum of 60 alphanumeric characters. The total string must be less than 255 characters (127 over Starnode). If a match string is not being used, a NONE should be entered in the string, as illustrated below. NONE NONE NONE NONE NONE NONE NONE NONE Note: The spaces are used as delimiters between the match strings.
Decoding Processor (DSP) Parameters Parameters 060-069 (?807) ?807
01280
00012
00015
00003
00431
00020
00195
00018
00004
00000 fixed label length min label length max label length max feature length # segment buffers segment length segment life max end mismatch min overlap timing tolerance
Parameters 070-079 (?808) ?808
00014
00050
00001
0
0
0
00135
00003
00007
0 cix enable cix symbology min x ticks max x ticks hot read mode match overlay discard rate bar count threshold match tolerance divisor min segment length
Rev F, February 2002
CiMAX 75xxA/76xx Scanner Technical Reference Manual
A-5
Group Setup Strings
A
Group Setup Parameter String Formats
Page 178
Appendix
A
Group Setup Strings
DSP Autosetup Parameters Parameters 080-095 (?809) ?809 0 0 15 35 022 080 200 04 16 01000 150 01 003 0 0 0 0 tunnel multi-reads remove C39 subsets track C39 lengths tunnel C39 FIFO symbology (add: 1, 2, 4, 8, 16, 32) lines of text (0 to 99) conveyor speed (0 to 999) ft/min label height (0 to 32767) in mils max label length (0 to 99), # of data characters min label length (0 to 99) # of data characters max distance (024 to 780) in .1” units min distance (024 to 780) in .1” units ratio (000 to 999) in xx.x:1 units max x dimension (00 to 99) in mils min x dimension (00 to 99) in mils reserved autosetup (0 or 1)
A-6
CiMAX 75xxA/76xx Scanner Technical Reference Manual
Rev F, February 2002
Page 179
A Group Setup Strings
Group Setup Parameter String Formats
Host & Terminal Port Serial Communications Parameters Parameters 100-114 (?810), 200-210 (?820) ?810 7 7 0 1 09 255 013 255 128 255 255 000 000 0 0000 ?820 7 7 0 1 09 255 013 255 128 255 255 modbus preset reg com protocol slave no/addr scanner addr error character output suffix2 output suffix1 output prefix input suffix input prefix transmit protocol number of stop bits (1 or 2) parity scheme (0-space, 1-mark, 2-even, 3-odd, 4-none) number of data bits (7 or 8) baud rate (7-9600, 8-19.2k, 9-38.4k)
Lan Port Comms & Messages Parameters Parameters 400-403 (?840) and 405-408, 413, 414 (?841) ?840
0
0000
000
126 message character terminal type terminal number network (0-serial, 1-starnode, 2-tcp/ip, 3-starnode+tcp/ip)
The following parameter applies to CiMAX 7500A only ?841
002
003
126
8510
1
255 enetcr brdcst tsrvprt tmchrl tmsu01 tmpr01
Rev F, February 2002
CiMAX 75xxA/76xx Scanner Technical Reference Manual
A-7
Page 180
Appendix
A
Group Setup Strings
Parameters 409-412, 415 (?842) - CiMAX 75xxA only ?842 000.000.000.000 000.000.000.000 255.255.255.000 000.000.000.000 000000000000 enetaddr dfgate sbnmask tsrvipad ipaddr
Digital Potentiometers (Parameters 444-459) ?844 050 motor speed
The scanner temporarily turns off the power to all laser diodes when any digital potentiometer string is loaded, to prevent current spikes from shortening diode life. ?845
000
000
000
099
000
000
099
072
020
000 opt rcvr gain opt rcvr shift opt rcvr thresh opt rcvr limit raster ampl pot raster freq pot phase laser pwr limit laser power (coarse) laser power (fine)
Digital Jumpers Parameters Parameter 495 (?849) ~?849 00010011~
A-8
CiMAX 75xxA/76xx Scanner Technical Reference Manual
Rev F, February 2002
Page 181
Presence Inputs, Relay Types & Debounce Times Parameters Parameters 501, 503-506, 510-518 (?850) ?850 0 0 0000 xxxxxxx1 xxxxxx1x 042 063 20 20 20 20 20 20 20 20 00000000 debounce type in8 dbnc time in7 dbnc time in6 dbnc time in5 dbnc time in4 dbnc time in3 dbnc time in2 dbnc time in1 dbnc time zone error 2 char (?) zone error 1 char (*) outzone input assignment (x-don’t care, 0-clear, 1-set) inzone input assignment (x-don’t care, 0-clear, 1-set) reserved for future use presence enabled (0-disabled, 1-inzone-outzone, 2-inzone only) reserved for future use
Relay Outputs Parameters Parameters 541-543, 553-560 (?852) ?852 xxxxxxx1 xxxxxx1x xxxxx1xx 0000 0000 0000 0000 0000 0000 0000 0000 rly hold 8 rly hold 7 rly hold 6 rly hold 5 rly hold 4 rly hold 3 rly hold 2 rly hold 1 no read assignment (x-don’t care, 0-clear, 1-set) match assignment (x-don’t care, 0-clear, 1-set) no match assignment (x-don’t care, 0-clear, 1-set)
Rev F, February 2002
CiMAX 75xxA/76xx Scanner Technical Reference Manual
A-9
Group Setup Strings
A
Group Setup Parameter String Formats
Page 182
Appendix
A
Group Setup Strings
User Program Parameters Parameters 600-601 (?860) ?860
02
0032
0 reserved file system size 2kb-1024kb stack size 2kb-32kb
User Variables Parameters Parameters 610-625 (?861) ?861 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 user var. 16 user variable 15 user variable 14 user variable 13 user variable 12 user variable 11 user variable 10 user variable 9 user variable 8 user variable 7 user variable 6 user variable 5 user variable 4 user variable 3 user variable 2 user variable 1
A-10
CiMAX 75xxA/76xx Scanner Technical Reference Manual
Rev F, February 2002
Page 183
Gap Tracking & Tachometer Input Parameters Parameters 700-709, 726-731 (?870) ?870
0
4
000
040
020
240
0170
0170
0
000
0 45
0
020
0170
0170 oz-ctr iz-ctr label tolerance box faces tunnel mtg angle scan delay comp rotation angle endpoint table outzone-center dist inzone-center dist conveyor width box tolerance outzone tolerance mils/tick encoder update rate tracking
Rev F, February 2002
CiMAX 75xxA/76xx Scanner Technical Reference Manual
A-11
Group Setup Strings
A
Group Setup Parameter String Formats
Page 184
Appendix
A
Group Setup Strings
Height Detect Parameters Parameters 710-719, 725, 732, 733, 743, 744 (?871) ?871
030
090
150
210
000
180
000
180
000
000
0
1
1 096 + Box Tolr Sign Array PIC position PIC ser port PIC photoeyes fixed conveyor speed fixed box length max height above conveyor min height above conveyor conveyor to scanner height 5 height 4 height 3 height 2 height 1
Label Tracking Ten parameters can be adjusted to increase the label-tracking accuracy of each scanner installation. These parameters adjust internally calculated label positions such that they more closely approximate actual label positions. Unlike other parameters, these ten parameters are un-numbered and can only be uploaded and downloaded by means of group setup string ?X89, illustrated below with default values. Nondefault values should only be used when the alternate endpoint table is selected (by setting parameter 708 ENDPOINT TBL = 1). The group setup strings have the following format: ?889 +36 -36 +03750 +03750 +03750 +03750 +03750 +03750 +03750 +03750
A-12
•
The first parameter (default = +36 = +36°) is the maximum scan beam angle. This is the angle between a perpendicular drawn from the scan zone origin to the scan beam and a line drawn from the origin to the end of the scan line that is farthest away from the origin, with both lines in the plane of the conveyor.
•
The second parameter (default = -36 = -36°) is the minimum scan beam angle. This is the angle between a perpendicular drawn from the scan zone origin to the scan beam and a line drawn from the origin to the end of the scan line that is nearest to the origin, with both lines in the plane of the conveyor.
•
Parameters 3, 5, 7 and 9 (default = +03750 = +3.75%) are the percentages of scan line offset subtracted from the inward scanning beams. This offset compensates for the error in the actual start-of-scan point caused by the gap between the down mirrors.
CiMAX 75xxA/76xx Scanner Technical Reference Manual
Rev F, February 2002
Page 185
•
Rev F, February 2002
Parameters 4, 6, 8 and 10 (default = +03750 = +3.75%) are the percentages of scan line offset added to the outward scanning beams This offset compensates for the error in the actual endof-scan point caused by the apex of the spinning polygon mirror.
CiMAX 75xxA/76xx Scanner Technical Reference Manual
A-13
Group Setup Strings
A
Group Setup Parameter String Formats
Page 186
Appendix
A-14
A
Group Setup Strings
CiMAX 75xxA/76xx Scanner Technical Reference Manual