Page 81
Reading Barcodes
FIGURE 4–23. 10X Quiet Zones on All Sides
FIGURE 4–24. With Human Readable Text Outside of 10X Quiet Zone
If this spacing is not possible, then the quiet zone should be located outside of this text data, with the text limited to only one line, as shown in Figure 4–25. The scanner can usually accommodate this extraneous text if it has been programmed to expect such a pattern, and if the amount of such text is minimal. The amount of this text must be relatively small when compared to the real barcode scanned in any given scan.
Rev F, February 2002
CiMAX 75xxA/76xx Scanner Technical Reference Manual
4 Introduction to Scanning
In some cases, codes include human readable alphanumeric text next to the code. This text allows people to manually read the barcode. When this human-readable text is necessary, it is better to have the quiet zone between the barcode and the human readable text as shown in Figure 4–24.
4-17
Page 82
Chapter
4
Introduction to Scanning
FIGURE 4–25. One Line of Human Readable Text Within 10X Quiet Zone
Other printing along the edge of a code, such as the bearer bars used with codes printed on corrugated boxes in the UPC Shipping Container Code, for instance, may also be accommodated. To accommodate these bearer bars, there must be a quiet zone outside of the printing. The printed area should also be relatively small when compared to the code area scanned in the same scan as the printing. Other human-readable printing or identifying marks on the label should be printed outside of the quiet zone surrounding the barcode, as shown in Figure 4–26. FIGURE 4–26. With Small Bearer Bars Within 10X Quiet Zone
Figure 4–27, Figure 4–28, and Figure 4–29 are examples of barcodes that may not read reliably. FIGURE 4–27. Reduced Performance Barcode - Example 1
4-18
CiMAX 75xxA/76xx Scanner Technical Reference Manual
Rev F, February 2002
Page 83
Reading Barcodes
FIGURE 4–28. Reduced Performance Barcode - Example 2
4 Introduction to Scanning
FIGURE 4–29. Reduced Performance Barcode - Example 3
Processing Barcode Data After potential barcode data has been framed between leading and trailing quiet zones, it is exported to the selected decode software routines in the scanner for further analysis and possible decoding. The scanner then attempts to match the data with one of the user-defined decode format strings. For maximum decoding efficiency, the decode format string should contain only the symbologies and label lengths you want to decode. In scanning applications where a variable number of ASCII characters are encoded in each barcode, the Minimum Label Length and Maximum Label Length parameters should be set. Pre-sorting of fixed-length barcodes occurs in much the same way. Any barcode that does not meet the length restrictions will be rejected before decoding is attempted.
Data Transmission Decoded barcode data is transmitted to the host computer or to C program control in a standard format or presentation. The output message sent from the scanner has the following format: prefix DATA suffix 1 suffix 2
Rev F, February 2002
CiMAX 75xxA/76xx Scanner Technical Reference Manual
4-19
Page 84
Chapter
4
Introduction to Scanning
The prefix, suffix 1 and suffix 2 characters are optional. They may be selected by setup parameters to be any ASCII characters. A typical message might look like this: 123456CRLF where: 123456 - Decoded data from a six-digit barcode (no prefix character has been selected) CR - The single ASCII character for Carriage Return (suffix 1) LF - The single ASCII character for Line Feed (suffix 2). The scanner's reading can be controlled by a presence signal from a photocell or other control device. If presence control has been selected and no barcode was read during the presence cycle, then the output message will be sent with a single ASCII ? character as the data field. (? means no label.) A no label and a no read message (variable length codes) for the above example would be: ?CRLF If you have selected reading fixed length codes, then the number of ? will equal the number of characters you selected to read. For example, if you selected six characters, then the no read message will be: ??????CRLF The default no-read character ? can be changed to any other ASCII character, using parameter 056. Refer to the Scanner Parameters Reference Guide for more information.
When Output Message is Sent You can select setup parameters to send the output message at any one of three times in the reading cycle. 1.
If the scanner's reading is controlled by a presence signal from a photocell or other control device, the output message can be sent at the end of the presence cycle. This is the normal and preferred method. It has the advantages of control of the reading cycle, scanning of the entire labeled object before output message transmission and transmitting only one message per box for synchronization and counting by the receiving device.
2.
If presence control is not possible, the output message can be sent after the barcode is no longer under the scanning beam, allowing it to be scanned and decoded as many times as possible, to provide reading redundancy and reliability. This method may cause problems with multiple transmissions per label.
3.
The output message can be sent after a selectable minimum number, or threshold, of decodes have occurred. This technique is least preferred because it forces transmission prior to decoding all possible scans of the label. It should only be used when an immediate response is required. For example, it allows an operator holding a box such that its barcode is under the scanner to move the box and set it down as soon as the barcode is decoded.
4-20
CiMAX 75xxA/76xx Scanner Technical Reference Manual
Rev F, February 2002
Page 85
Introduction to Scan Tunnel Applications
Introduction to Scan Tunnel Applications A scan tunnel consists of a group of barcode scanners arranged in an array around a conveyor such that a barcode located on any surface of a box moving on the conveyor can be read. In this explanation, we call the objects moving on the conveyor boxes, but they could just as well be suitcases, parcels, trays or other objects with barcode labels on them or on attached tags. Some of the variables which must be considered when designing a scan tunnel are: size and shape of boxes; speed of conveyor; number of box sides to be scanned; barcode characteristics; and distance limitations, if any, on scanner placement.
Either CiMAX 7800 scanner, with CIX technology enabled, can be used to read barcodes located on the tops and sides of the boxes, depending upon the requirements of the specific application. CiMAX 7850 scanners, usually installed at the main conveyor's induction lanes, and with CIX technology enabled, can be used to read barcodes located on the bottoms of boxes. The scanners are mounted below the induction lane conveyors and scan the bottoms of the boxes as the boxes move across the gap between conveyors. In the following sections, two uses of the CiMAX 7800 and one use of the CiMAX 7850 are illustrated. The illustrations are provided as examples only - each scan tunnel must be individually designed after evaluating the user's specific requirements.
CiMAX 7800 Scanning Front/Back Boxes Figure 4–30 illustrates how CiMAX 7800 scanners can be mounted. It shows the areas each can scan when used to read barcodes in a scan tunnel. FIGURE 4–30. Scanning Front & Back of Box location 7 location 6 back of scan tunnel location 3 f r o n t b top of a box c k location 2 front of scan tunnel location 5 location 4
The conveyor moves from right to left when viewed from the front of the scan tunnel.
Rev F, February 2002
CiMAX 75xxA/76xx Scanner Technical Reference Manual
4-21
4 Introduction to Scanning
CiMAX 7800 scanners with auto-focusing capability can be used to read barcodes on the ends of boxes as the boxes approach and leave the scan zone. Both vertical and horizontal scanning is implemented such that, with CIX technology enabled, barcodes oriented in any direction on the ends of the boxes can be read.
Page 86
Chapter
4
Introduction to Scanning
Locations 2 and 3 may have two scanners, mounted one above the other. The upper scanner in location 3 scans the upper area of the front of the box. The lower scanner in location 3 scans the lower area of the front of the box. Locations 5 and 7 are also divided. The scanner in location 5 scans the right-hand area of the front of the box. The scanner in location 7 scans the left-hand area of the front of the box. The horizontal laser beams overlap the vertical beams. Figure 4–31 shows the sections of the box fronts covered by scanners 7, 3 and 5. Scanners 6, 2 and 4 cover the box backs in the same way. All mounting angles are shown as 45° skew, 0° pitch and 0° tilt. Other skew angles are possible, with appropriate adjustments of parameter 727 TUNNEL MTG ANGLE. FIGURE 4–31. Scanner Coverage Identification
Front of Box
Front of Box
Location 3 Upper scanner (Horizontal beams)
Location 7 Scanner
Location 3 Lower scanner
Location 5 Scanner
(Vertical beams)
Figure 4–32 shows, in more detail, the mounting geometry of a typical scanner relative to the conveyor. FIGURE 4–32. Mounting Geometry of Typical Scanner a. Conveyor to scanner distance b. Tunnel mounting angle c. Inzone minus Center d. Outzone minus Center e. Minimum focus f. Maximum focus e f a photoeye b
900 photoeye
Conveyor Surface Outzone d c
Center
Inzone
Whenever a scanner is mounted to read at other than 90°, as illustrated in Figure 4–32, it must have parameter 700 TRACKING set correctly to see barcodes. Refer to parameter 700 TRACKING in the Scanner Parameters Reference Guide for more information. Parameter 728 FRONT/BACK ONLY can be set such that scanners setup to read barcodes on the fronts and backs of boxes will reject barcodes read on the top and sides. 4-22
CiMAX 75xxA/76xx Scanner Technical Reference Manual
Rev F, February 2002
Page 87
Introduction to Scan Tunnel Applications
CiMAX 7800 Scanning Front, Back, Top & Side Boxes Figure 4–33 illustrates how CiMAX 7800 scanners can be mounted to read barcodes on the tops and sides, as well as the fronts and backs, of boxes in a scan tunnel. Slaves 004 and 007 are set up to read the sides, slaves 005 and 006 to read the tops, slaves 002 and 003 to read the fronts and slave 001 and master 000 to read the backs. FIGURE 4–33. Scanning Front, Back, Top and Side of Box x007 - Slave 7 x006 - Slave 6 x003 - Slave 3 x001 - Slave 1
4 x002 - Slave 2 x005 - Slave 5
Introduction to Scanning
Direction Of Travel x000 - Master x004 - Slave 4
CiMAX 7850 Scanning Bottoms of Boxes Figure 4–34 illustrates how a CiMAX 7850 scanner can be mounted to scan the bottom of boxes as they move across an induction line conveyor gap. The gap is shown oversize for clarity. If the orientation of the barcodes on the boxes can not be controlled, the same barcode must be printed both vertically and horizontally on each label (and on both sides, if a baggage tag) such that, with CIX technology enabled, barcodes oriented in any direction on the bottoms of the boxes can be read by the scanner. FIGURE 4–34. Scanner Viewing Bottom of Box
Laser Beam Box
Direction Of Travel
Scanner
Conveyor
Rev F, February 2002
CiMAX 75xxA/76xx Scanner Technical Reference Manual
4-23
Page 88
Chapter
4
Introduction to Scanning
Scan Tunnel Control The scan tunnel software runs in a PC under Windows NT, for its real-time processing speed. It coordinates communication among all of the scanners, collects the transmissions from the group and transmits the data associated with each specific box to a host computer. The data is transmitted to the host at a time determined by an input signal from the scanner system, to allow the host to associate each data transmission with a specific box located at a specific position on the moving conveyor. The tunnel software also provides diagnostic capability for the scanners and real-time monitoring of scanner performance.
Interface Units Interface Units, which provide power and interface connections for up to six scanners, are available, to reduce the amount of system wiring required.
Additional Information For additional information about specific scan tunnel applications, consult your Keysheet or contact SICK Auto Ident, Inc. directly.
4-24
CiMAX 75xxA/76xx Scanner Technical Reference Manual
Rev F, February 2002