Page 1 of 76xx/7200/7400 Utility Interface Box User's Manual

Manual · Sick

76xx/7200/7400 Utility Interface Box User's Manual

Manual29 pagesPDF 259 KB

User's manual for the SICK 76xx/7200/7400 utility interface box that powers and connects CiMAX-76xx and CiPro-7200/7400 scanners.

Download the PDF259 KB

Filed with · 11 models

Also filed with these models on the old site

Summary

What is in it

The user's manual for the SICK 76xx/7200/7400 Utility Interface Box, in AC/DC (A1-63207-2) and DC/DC (A1-63207-3) versions. The box is a circuit board on a cover plate that fits a quad utility box, powers a CiMAX-76xx, CiPro-7200 or CiPro-7400 scanner and brings out its inputs, outputs and communications. The manual covers input power wiring, connecting the scanner, the main and auxiliary ports, presence sensor and LED jumpers, scanner setup for master/slave and pass through configurations, technical specifications and mechanical assembly.

Its parts

  1. Introduction
  2. Making Connections
  3. Scanner Setup
  4. Technical Specifications
  5. Mechanical Assembly

From the manual · read page by page

Key facts from this manual

Each line names its page in the PDF.

User's manual (EM-63217-2E, Rev E) for the 76xx/7200/7400 Utility Interface Box from SICK Auto Ident, in its AC/DC version A1-63207-2 and DC/DC version A1-63207-3. The box powers a CiMAX-76xx, CiPro-7200 or CiPro-7400 scanner and brings out its inputs, outputs and serial ports. It shows how to wire power and sensors, set the jumpers, scan in a verifier code and build master/slave or pass-through scanner networks.

What it is
Circuit board on a cover plate that fits a quad utility box; powers the scanner and gives easy access to its inputs, outputs and communications p. 8
Versions
A1-63207-2 AC/DC Utility Interface Box; A1-63207-3 DC/DC Utility Interface Box p. 5
Scanners served
CiMAX-76xx, CiPro-7200 and CiPro-7400 p. 8
AC input power
A1-63207-2: 100-240VAC source on terminal block TB1 p. 8
DC input power
A1-63207-3: 18-36 VDC source on terminal block TB3 p. 9
Scanner connector
DB25 plug on the cover plate; mates with the DB25 socket on the CiPro-7200 and CiPro-7400 scanner cable p. 10
CiMAX-76xx cables
A1-63345-1 or A1-63345-2, 8 foot; A1-63345-2 makes no communication connections to the scanner p. 10
Main port
DB9F plug-in connector, RS232 or RS485 p. 6
Auxiliary port
DB9M plug-in connector, RS232 p. 6
Inputs
One presence sensor input, NPN or PNP (CiPro-7200/7400); three inputs (CiMAX-76xx); +12VDC for sensor power p. 25
Outputs
Three outputs: No Read, Match and No Match; +12VDC for relay power p. 25
Status LEDs
Three LEDs driven by scanner outputs 1, 2, 3 through jumpers JH1, JH2, JH3, set to OFF by default p. 16
Scanner networks
One master and up to 5 slaves on a multi-drop RS485 network, or a pass-through (daisy chain) of scanners p. 21, 23
Setup software
CiWINSET, over a straight through 9-pin male/female cable from the Main DB9F to a PC serial port p. 18

What this manual walks you through

  • Wiring AC or DC input power to the terminal block p. 8, 9
  • Connecting the scanner to the box through the DB25 p. 10, 11, 12
  • Pinouts of the Main and Auxiliary DB9 ports p. 12, 13, 14
  • Wiring the presence sensor and scanner outputs on TB2 p. 14, 15
  • Setting the LED output and presence sensor jumpers p. 16, 17
  • Scanning in a CiPro-7200/7400 verifier code p. 18, 19, 20
  • Setting up a master/slave scanner network p. 21, 22
  • Wiring a pass-through (daisy chain) configuration p. 23, 24

Good to know

  • The box is meant only for installation in an electrical junction box, by a qualified electrician. p. 5
  • On the DC version, do not connect input ground to earth ground; earth ground is for shielding. p. 9
  • The LEDs are pulled up to +12V and should be used only when nothing is connected to the TB2 outputs. p. 16
  • Inputs and outputs are opto-isolated at the CiPro-7200/7400 scanner but single ended on the box's terminal strip. p. 14
  • Scanning in the verifier label saves the whole scanner configuration to EEPROM, so all parameters must be correct first. p. 18

Questions this manual answers

What input voltage does the 76xx/7200/7400 utility box take?

The AC/DC version A1-63207-2 takes 100-240VAC on terminal block TB1; the DC/DC version A1-63207-3 takes 18-36 VDC on TB3. p. 8, 9

Which cable connects a CiMAX-76xx scanner to the utility box?

An 8 foot A1-63345-1 or A1-63345-2 cable. The A1-63345-2 makes no communication connections, so communications go to the scanner itself. p. 10

How do I set the utility box jumpers for an NPN presence sensor?

For a CiPro-7200/7400 with an NPN sensor, put one shunt over J2 pins 1 and 2 and the other over pins 3 and 4; presence is active on a low signal at P-. p. 16

How many scanners can share one presence sensor in a master/slave setup?

One master and up to 5 slaves, linked on a multi-drop RS485 network through their Main ports, with the presence inputs jumpered together to a single sensor. p. 21

How do I program a CiPro-7200/7400 scanner through the utility box?

Connect a straight through 9-pin male/female cable from the box's Main DB9F to a PC serial port and set the parameters with the CiWINSET program. p. 18

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. 76xx/7200/7400 Utility Interface Box User’s Manual1
    1. CHAPTER 1 Setup and Use 13
    2. Index 254
  2. Introduction5
    1. Features6
    2. Description8
    3. AC Input Power (A1-63207-2 only)8
    4. DC Input Power (A1-63207-3 only)9
  3. Making Connections10
    1. Scanner to Utility Interface Box10
    2. Main and Auxiliary Communications Ports12
    3. Presence Sensor Input and Scanner Outputs14
    4. Setting LED Output Jumpers16
    5. Setting Presence Sensor Jumpers16
  4. Scanner Setup18
    1. Setting Scanner Parameters18
    2. Setting Up for Master/Slave Configurations21
    3. Setting Up for Pass Through Configurations23
  5. Technical Specifications25
    1. Electrical25
    2. Inputs25
    3. Outputs25
    4. Communications26
    5. Cables26
  6. Mechanical Assembly27
    1. Printed Circuit Board28

From the PDF’s own bookmarks.

The whole text · 5 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. 76xx/7200/7400 Utility Interface Box User’s Manual1-4
  2. Introduction5-9
  3. Making Connections10-17
  4. Scanner Setup18-24
  5. Pages 25 to 2925-29

The file

Revision and size

RevisionEM-63217-2E Rev E, February 2002
PublisherSICK Auto Ident, Inc.
Pages29
PDF259 KB
TextText from the PDF itself.

The first pages · 3 of 29

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 29
Page 2
Page 2of 29
Page 3
Page 3of 29