Manual · Sick
76xx/7200/7400 Utility Interface Box User's Manual
Manual29 pagesPDF 259 KB
User's manual for the SICK 76xx/7200/7400 utility interface box that powers and connects CiMAX-76xx and CiPro-7200/7400 scanners.
Filed with · 11 models
Also filed with these models on the old site
RVSI CiMatrix 7555ADecoded fixed-mount laser barcode scanner from$1,295.0013 in stock
Sick 7555ADecoded fixed-mount laser barcode scanner from$1,295.0013 in stock
RVSI CiMatrix 7655Decoded fixed-mount laser barcode scanner from$1,295.001 in stock
RVSI CiMatrix 7800Decoded fixed-mount laser barcode scanner from$1,995.0016 in stock
Siemens 7555ADecoded fixed-mount laser barcode scanner Call for availability
Siemens 7655Decoded fixed-mount laser barcode scanner Call for availability
Siemens 7800Decoded fixed-mount laser barcode scanner Call for availability Summary
What is in it
The user's manual for the SICK 76xx/7200/7400 Utility Interface Box, in AC/DC (A1-63207-2) and DC/DC (A1-63207-3) versions. The box is a circuit board on a cover plate that fits a quad utility box, powers a CiMAX-76xx, CiPro-7200 or CiPro-7400 scanner and brings out its inputs, outputs and communications. The manual covers input power wiring, connecting the scanner, the main and auxiliary ports, presence sensor and LED jumpers, scanner setup for master/slave and pass through configurations, technical specifications and mechanical assembly.
Its parts
- Introduction
- Making Connections
- Scanner Setup
- Technical Specifications
- Mechanical Assembly
From the manual · read page by page
Key facts from this manual
Each line names its page in the PDF.
User's manual (EM-63217-2E, Rev E) for the 76xx/7200/7400 Utility Interface Box from SICK Auto Ident, in its AC/DC version A1-63207-2 and DC/DC version A1-63207-3. The box powers a CiMAX-76xx, CiPro-7200 or CiPro-7400 scanner and brings out its inputs, outputs and serial ports. It shows how to wire power and sensors, set the jumpers, scan in a verifier code and build master/slave or pass-through scanner networks.
- What it is
- Circuit board on a cover plate that fits a quad utility box; powers the scanner and gives easy access to its inputs, outputs and communications p. 8
- Versions
- A1-63207-2 AC/DC Utility Interface Box; A1-63207-3 DC/DC Utility Interface Box p. 5
- Scanners served
- CiMAX-76xx, CiPro-7200 and CiPro-7400 p. 8
- AC input power
- A1-63207-2: 100-240VAC source on terminal block TB1 p. 8
- DC input power
- A1-63207-3: 18-36 VDC source on terminal block TB3 p. 9
- Scanner connector
- DB25 plug on the cover plate; mates with the DB25 socket on the CiPro-7200 and CiPro-7400 scanner cable p. 10
- CiMAX-76xx cables
- A1-63345-1 or A1-63345-2, 8 foot; A1-63345-2 makes no communication connections to the scanner p. 10
- Main port
- DB9F plug-in connector, RS232 or RS485 p. 6
- Auxiliary port
- DB9M plug-in connector, RS232 p. 6
- Inputs
- One presence sensor input, NPN or PNP (CiPro-7200/7400); three inputs (CiMAX-76xx); +12VDC for sensor power p. 25
- Outputs
- Three outputs: No Read, Match and No Match; +12VDC for relay power p. 25
- Status LEDs
- Three LEDs driven by scanner outputs 1, 2, 3 through jumpers JH1, JH2, JH3, set to OFF by default p. 16
- Scanner networks
- One master and up to 5 slaves on a multi-drop RS485 network, or a pass-through (daisy chain) of scanners p. 21, 23
- Setup software
- CiWINSET, over a straight through 9-pin male/female cable from the Main DB9F to a PC serial port p. 18
What this manual walks you through
- Wiring AC or DC input power to the terminal block p. 8, 9
- Connecting the scanner to the box through the DB25 p. 10, 11, 12
- Pinouts of the Main and Auxiliary DB9 ports p. 12, 13, 14
- Wiring the presence sensor and scanner outputs on TB2 p. 14, 15
- Setting the LED output and presence sensor jumpers p. 16, 17
- Scanning in a CiPro-7200/7400 verifier code p. 18, 19, 20
- Setting up a master/slave scanner network p. 21, 22
- Wiring a pass-through (daisy chain) configuration p. 23, 24
Good to know
- The box is meant only for installation in an electrical junction box, by a qualified electrician. p. 5
- On the DC version, do not connect input ground to earth ground; earth ground is for shielding. p. 9
- The LEDs are pulled up to +12V and should be used only when nothing is connected to the TB2 outputs. p. 16
- Inputs and outputs are opto-isolated at the CiPro-7200/7400 scanner but single ended on the box's terminal strip. p. 14
- Scanning in the verifier label saves the whole scanner configuration to EEPROM, so all parameters must be correct first. p. 18
Questions this manual answers
What input voltage does the 76xx/7200/7400 utility box take?
The AC/DC version A1-63207-2 takes 100-240VAC on terminal block TB1; the DC/DC version A1-63207-3 takes 18-36 VDC on TB3. p. 8, 9
Which cable connects a CiMAX-76xx scanner to the utility box?
An 8 foot A1-63345-1 or A1-63345-2 cable. The A1-63345-2 makes no communication connections, so communications go to the scanner itself. p. 10
How do I set the utility box jumpers for an NPN presence sensor?
For a CiPro-7200/7400 with an NPN sensor, put one shunt over J2 pins 1 and 2 and the other over pins 3 and 4; presence is active on a low signal at P-. p. 16
How many scanners can share one presence sensor in a master/slave setup?
One master and up to 5 slaves, linked on a multi-drop RS485 network through their Main ports, with the presence inputs jumpered together to a single sensor. p. 21
How do I program a CiPro-7200/7400 scanner through the utility box?
Connect a straight through 9-pin male/female cable from the box's Main DB9F to a PC serial port and set the parameters with the CiWINSET program. p. 18
Contents
Chapters and sections
Each line opens the PDF at its page.
The whole text · 5 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file