Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 2 of 5

76xx/7200/7400 Utility Interface Box User's Manual: Introduction

Pages 5 to 9 of 29, from 76xx/7200/7400 Utility Interface Box User's Manual

The original document is the PDF (259 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the RVSI CiMatrix 7555A, Sick 7555A, RVSI CiMatrix 7600, RVSI CiMatrix 7655, RVSI CiMatrix 7800, Sick 7850, Siemens 7555A, Sick 7600, and 3 more models

Page 5

Introduction CHAPTER 1

Setup and Use

Introduction This manual describes the functionality and use of the following products: •

A1-63207-2: 76xx/7200/7400 AC/DC Utility Interface Box

•

A1-63207-3: 76xx/7200/7400 DC/DC Utility Interface Box

WARNING! THIS PRODUCT IS INTENDED ONLY FOR INSTALLATION IN AN ELECTRICAL JUNCTION BOX, AND SHOULD BE INSTALLED ONLY BY A QUALIFIED ELECTRICIAN.

Rev E, February 2002

76xx/7200/7400 Utility Interface Box

1

Page 6

Introduction

Features The main features of the Utility Boxes are: •

1 Presence input connection for CiPro-7200/7400, NPN or PNP presence sensor

•

3 input connections for CiMAX-76xx

•

3 output connections

•

Main plug-in connector for RS232 or RS485 communication (DB9F)

•

Auxiliary plug-in connector for RS232 communication (DB9M)

•

Three LEDs controlled by the scanner’s output signals (Jumper selectable)

The top plate with the connectors and components must be mounted onto the junction box, as shown in Figure 1.

2

76xx/7200/7400 Utility Interface Box

Rev E, February 2002

Page 7

Introduction FIGURE 1. 76xx/7200/7400 AC/DC Utility Interface Box

Note: Lead all wiring through the large knockout holes in the junction box, using proper bushing hardware.

Rev E, February 2002

76xx/7200/7400 Utility Interface Box

3

Page 8

Introduction

Description The 76xx/7200/7400 AC/DC Utility Interface Box (A1-63207-2) (‘AC Utility Box’) and the 76xx/7200/ 7400 DC/DC Utility Interface Box (A1-63207-3) (‘DC Utility Box’) consist of a printed circuit board, mounted on a cover plate, which is intended to fit within a quad utility box. These utility boxes provide power to a CiMAX-76xx, CiPro-7200, or a CiPro-7400 scanner, and allow easy connection to scanner inputs, outputs, and communications signals.

AC Input Power (A1-63207-2 only) The terminal block TB1 on the printed circuit board is used to connect a 100-240VAC source. TABLE 1. AC Input Power

Pin

Name

Function

1

LINE

100-240VAC Line (Brown)

2

NEUT

100-240VAC Neutral (Blue)

3

CHG

100-240VAC Ground (Green/Yellow)

4

76xx/7200/7400 Utility Interface Box

Rev E, February 2002

Page 9

Introduction

DC Input Power (A1-63207-3 only) The terminal block TB3 on the printed circuit board is used to connect an 18-36 VDC source. Note: Do not connect Input Ground to Earth Ground. Earth Ground is used for shielding purposes. TABLE 2. DC Input Power

Pin

Name

Function

1

DCIN+

DC Input + Voltage

2

DCIN-

DC Input Ground

3

CHG

Earth Ground

Rev E, February 2002

76xx/7200/7400 Utility Interface Box

5