Page 5
Introduction CHAPTER 1
Setup and Use
Introduction This manual describes the functionality and use of the following products: •
A1-63207-2: 76xx/7200/7400 AC/DC Utility Interface Box
•
A1-63207-3: 76xx/7200/7400 DC/DC Utility Interface Box
WARNING! THIS PRODUCT IS INTENDED ONLY FOR INSTALLATION IN AN ELECTRICAL JUNCTION BOX, AND SHOULD BE INSTALLED ONLY BY A QUALIFIED ELECTRICIAN.
Rev E, February 2002
76xx/7200/7400 Utility Interface Box
1
Page 6
Introduction
Features The main features of the Utility Boxes are: •
1 Presence input connection for CiPro-7200/7400, NPN or PNP presence sensor
•
3 input connections for CiMAX-76xx
•
3 output connections
•
Main plug-in connector for RS232 or RS485 communication (DB9F)
•
Auxiliary plug-in connector for RS232 communication (DB9M)
•
Three LEDs controlled by the scanner’s output signals (Jumper selectable)
The top plate with the connectors and components must be mounted onto the junction box, as shown in Figure 1.
2
76xx/7200/7400 Utility Interface Box
Rev E, February 2002
Page 7
Introduction FIGURE 1. 76xx/7200/7400 AC/DC Utility Interface Box
Note: Lead all wiring through the large knockout holes in the junction box, using proper bushing hardware.
Rev E, February 2002
76xx/7200/7400 Utility Interface Box
3
Page 8
Introduction
Description The 76xx/7200/7400 AC/DC Utility Interface Box (A1-63207-2) (‘AC Utility Box’) and the 76xx/7200/ 7400 DC/DC Utility Interface Box (A1-63207-3) (‘DC Utility Box’) consist of a printed circuit board, mounted on a cover plate, which is intended to fit within a quad utility box. These utility boxes provide power to a CiMAX-76xx, CiPro-7200, or a CiPro-7400 scanner, and allow easy connection to scanner inputs, outputs, and communications signals.
AC Input Power (A1-63207-2 only) The terminal block TB1 on the printed circuit board is used to connect a 100-240VAC source. TABLE 1. AC Input Power
Pin
Name
Function
1
LINE
100-240VAC Line (Brown)
2
NEUT
100-240VAC Neutral (Blue)
3
CHG
100-240VAC Ground (Green/Yellow)
4
76xx/7200/7400 Utility Interface Box
Rev E, February 2002
Page 9
Introduction
DC Input Power (A1-63207-3 only) The terminal block TB3 on the printed circuit board is used to connect an 18-36 VDC source. Note: Do not connect Input Ground to Earth Ground. Earth Ground is used for shielding purposes. TABLE 2. DC Input Power
Pin
Name
Function
1
DCIN+
DC Input + Voltage
2
DCIN-
DC Input Ground
3
CHG
Earth Ground
Rev E, February 2002
76xx/7200/7400 Utility Interface Box
5