Page 10

Making Connections

Making Connections Scanner to Utility Interface Box The DB25 plug on the Utility Box cover plate mates with the DB25 socket that terminates the CiPro-7200 and CiPro-7400 scanner cable. When connecting the CiMAX-76xx scanner, you must use either (A1-63345-1) or (A1-63345-2) 8 foot cables. All power, communications, input, and output signals are present on the DB25. The A1-63345–2 cable makes no communication connections to the CiMAX-76xx scanner, so communications must be made to the scanner itself. The (A1-63345-1 rev B) and (A1-63345-2 rev C) have the additional input 3 connection, if required. Previous revisions of these cables do not. TABLE 3. Utility Box DB25 Pin Assignments

CiPro-7200/7400 Scanners

CiMAX-76xx Scanner

Pin

Name

Function

Name

Function

1

CHASSIS

Chassis ground

CHASSIS

Chassis ground

2

TX232/TX485+

Main port

Host TXD

Host port

3

RX232/RX485+

Main port

Host RXD

Host port

6

76xx/7200/7400 Utility Interface Box

Rev E, February 2002

Page 11

Making Connections TABLE 3. Utility Box DB25 Pin Assignments (Continued)

4

RTS232/TX485-

Main port

NC

No connect

5

CTS232/RX485-

Main port

NC

No connect

6

NC

No connect

IN3

Input 3

7

SGND

Signal ground

SGND

Signal ground

8

NO READ +

‘No Read’ output

OUT1

Output 1

9

VS

Presence supply

+12V

Power supply voltage

10

NC

No connect

NC

No connect

11

RIGHT+

‘Right’ output

OUT2

Output 2

12

RIGHT-

‘Right’ output

SGND

Signal ground

13

VS

Power supply

+12V

Power supply voltage

14

WRONG+

‘Wrong’ output

OUT3

Output 3

15

WRONG-

‘Wrong’ output

SGND

Signal ground

16

NC

No connect

NC

No connect

17

NC

No connect

NC

No connect

18

PS+

Presence sensor

IN1

Input 1

Rev E, February 2002

76xx/7200/7400 Utility Interface Box

7

Page 12

Making Connections TABLE 3. Utility Box DB25 Pin Assignments (Continued)

19

PS-

Presence sensor

IN2

Input 2

20

RXAUX

Auxiliary port

TERMRXD

Terminal port

21

TXAUX

Auxiliary port

TERMTXD

Terminal port

22

NO READ-

‘No Read’ output

NC

No connect

23

CTSAUX

Auxiliary port

NC

No connect

24

RTSAUX

Auxiliary port

NC

No connect

25

SGND

Signal ground

NC

No connect

Main and Auxiliary Communications Ports The Main DB9 socket on the cover plate is for access to the Main/Host communications port. Use a straight through 9-pin male/female cable to connect the Utility Box DB9 to a PC serial port to program the scanner and receive data.

8

76xx/7200/7400 Utility Interface Box

Rev E, February 2002

Page 13

Making Connections TABLE 4. Main DB9F Pin Out

Pin

Name

Function

1

MAINRTS/TX485-

Main port (output)

2

MAINTX232/TX485+

Main port (output)

3

MAINRX232/RX485+

Main port (input)

4

MAINCTS/RX485-

Main port (input)

5

SGND

Signal ground

6,7,8,9

NC

No connect

The AUX DB9 plug on the cover plate is for access to the AUX communications port. Use a straight through 9-pin male/female cable to connect the Utility Box DB9M to an additional standard utility box, if that scanner is set up in pass through mode. The Auxiliary port is also used in CiPro-7200/7400 verifier mode.

Rev E, February 2002

76xx/7200/7400 Utility Interface Box

9

Page 14

Making Connections TABLE 5. Auxiliary DB9M Pin Assignments

Pin

Name

Function

1

AUXCTS

Auxiliary port handshake (input)/Verifier Mode

2

AUXRX232

Auxiliary port RS232 (input)

3

AUXTX232

Auxiliary port RS232 (output)

4

AUXRTS

Auxiliary port handshake (output)/Verifier Mode

5

SGND

Signal ground

6,7,8,9

NC

No connect

Presence Sensor Input and Scanner Outputs The terminal block TB2 on the printed circuit board is used to access scanner inputs and outputs, and provides +12V for Presence sensor and/or relays. Note: Although the input and outputs are opto-isolated at the CiPro-7200/7400 scanner, they are single ended (referenced to Signal ground) on the Utility Box terminal strip.

10

76xx/7200/7400 Utility Interface Box

Rev E, February 2002

Page 15

Making Connections TABLE 6. TB2 Pin Out

Pin

Name

CiPro-7200/7400 function

CiMAX-76xx function

1 2

GND

Signal ground

Signal ground

+12V

Power for presence sensor, relays

Power for presence sensor, relays

3

O1

Scanner output: No Read

Output 1: No Read Led

4

O2

Scanner output: Right

Output 2: Match Led

5

O3

Scanner output: Wrong

Output 3: No Match Led

6

GND

Signal ground

Signal ground

7

I1/P+

+ Input from presence sensor (PNP)

Input 1

8

I2/P-

- Input from presence sensor (NPN)

Input 2

9

I3

Not used

Input 3

10

GND

Signal ground

Signal ground

Rev E, February 2002

76xx/7200/7400 Utility Interface Box

11

Page 16

Making Connections

Setting LED Output Jumpers The jumpers JH1, JH2, JH3 are used to connect outputs 1, 2, 3 to the LEDs respectively. These are set to OFF in the default position. The LEDs are pulled up to +12V and should be used only if no output connections are made to TB2.

Setting Presence Sensor Jumpers The jumper header J2 is used to configure the interface box for various types of input configurations. The factory default jumper positions are for a CiMAX-76xx scanner. •

For a CiPro-7200/7400 NPN presence sensor, place one shunt over pins 1 and 2, and the other shunt over pins 3 and 4. Presence will be active when a low signal is placed on the P- input.

•

For a CiPro-7200/7400 PNP presence sensor, place one shunt over pins 2 and 3, and the other shunt over pins 4 and 5. Presence will be active when a high signal is placed on the P+ input.

•

For a CiMAX-76xx scanner, place one shunt over pins 2 and 3, and the other shunt over pins 6 and 7. Inputs will be active when a low signal is placed on any of the three inputs.

12

76xx/7200/7400 Utility Interface Box

Rev E, February 2002

Page 17

Making Connections FIGURE 2. Presence Sensor Jumper Settings

Position for CiPro-7200/7400

Position for CiPro-76xx

PNP sensor

NPN sensor

J2

J2

+12 V

76xx/7200/7400 Utility Interface Box

GND +12 V

TB2

Rev E, February 2002

GND

TB2

+12 V

TB2

GND

J2

13