The text of a manual · part 3 of 5
76xx/7200/7400 Utility Interface Box User's Manual: Making Connections
Pages 10 to 17 of 29, from 76xx/7200/7400 Utility Interface Box User's Manual
The original document is the PDF (259 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the RVSI CiMatrix 7555A, Sick 7555A, RVSI CiMatrix 7600, RVSI CiMatrix 7655, RVSI CiMatrix 7800, Sick 7850, Siemens 7555A, Sick 7600, and 3 more models
Page 10
Making Connections
Making Connections Scanner to Utility Interface Box The DB25 plug on the Utility Box cover plate mates with the DB25 socket that terminates the CiPro-7200 and CiPro-7400 scanner cable. When connecting the CiMAX-76xx scanner, you must use either (A1-63345-1) or (A1-63345-2) 8 foot cables. All power, communications, input, and output signals are present on the DB25. The A1-63345–2 cable makes no communication connections to the CiMAX-76xx scanner, so communications must be made to the scanner itself. The (A1-63345-1 rev B) and (A1-63345-2 rev C) have the additional input 3 connection, if required. Previous revisions of these cables do not. TABLE 3. Utility Box DB25 Pin Assignments
CiPro-7200/7400 Scanners
CiMAX-76xx Scanner
Pin
Name
Function
Name
Function
1
CHASSIS
Chassis ground
CHASSIS
Chassis ground
2
TX232/TX485+
Main port
Host TXD
Host port
3
RX232/RX485+
Main port
Host RXD
Host port
6
76xx/7200/7400 Utility Interface Box
Rev E, February 2002
Page 11
Making Connections TABLE 3. Utility Box DB25 Pin Assignments (Continued)
4
RTS232/TX485-
Main port
NC
No connect
5
CTS232/RX485-
Main port
NC
No connect
6
NC
No connect
IN3
Input 3
7
SGND
Signal ground
SGND
Signal ground
8
NO READ +
‘No Read’ output
OUT1
Output 1
9
VS
Presence supply
+12V
Power supply voltage
10
NC
No connect
NC
No connect
11
RIGHT+
‘Right’ output
OUT2
Output 2
12
RIGHT-
‘Right’ output
SGND
Signal ground
13
VS
Power supply
+12V
Power supply voltage
14
WRONG+
‘Wrong’ output
OUT3
Output 3
15
WRONG-
‘Wrong’ output
SGND
Signal ground
16
NC
No connect
NC
No connect
17
NC
No connect
NC
No connect
18
PS+
Presence sensor
IN1
Input 1
Rev E, February 2002
76xx/7200/7400 Utility Interface Box
7
Page 12
Making Connections TABLE 3. Utility Box DB25 Pin Assignments (Continued)
19
PS-
Presence sensor
IN2
Input 2
20
RXAUX
Auxiliary port
TERMRXD
Terminal port
21
TXAUX
Auxiliary port
TERMTXD
Terminal port
22
NO READ-
‘No Read’ output
NC
No connect
23
CTSAUX
Auxiliary port
NC
No connect
24
RTSAUX
Auxiliary port
NC
No connect
25
SGND
Signal ground
NC
No connect
Main and Auxiliary Communications Ports The Main DB9 socket on the cover plate is for access to the Main/Host communications port. Use a straight through 9-pin male/female cable to connect the Utility Box DB9 to a PC serial port to program the scanner and receive data.
8
76xx/7200/7400 Utility Interface Box
Rev E, February 2002
Page 13
Making Connections TABLE 4. Main DB9F Pin Out
Pin
Name
Function
1
MAINRTS/TX485-
Main port (output)
2
MAINTX232/TX485+
Main port (output)
3
MAINRX232/RX485+
Main port (input)
4
MAINCTS/RX485-
Main port (input)
5
SGND
Signal ground
6,7,8,9
NC
No connect
The AUX DB9 plug on the cover plate is for access to the AUX communications port. Use a straight through 9-pin male/female cable to connect the Utility Box DB9M to an additional standard utility box, if that scanner is set up in pass through mode. The Auxiliary port is also used in CiPro-7200/7400 verifier mode.
Rev E, February 2002
76xx/7200/7400 Utility Interface Box
9
Page 14
Making Connections TABLE 5. Auxiliary DB9M Pin Assignments
Pin
Name
Function
1
AUXCTS
Auxiliary port handshake (input)/Verifier Mode
2
AUXRX232
Auxiliary port RS232 (input)
3
AUXTX232
Auxiliary port RS232 (output)
4
AUXRTS
Auxiliary port handshake (output)/Verifier Mode
5
SGND
Signal ground
6,7,8,9
NC
No connect
Presence Sensor Input and Scanner Outputs The terminal block TB2 on the printed circuit board is used to access scanner inputs and outputs, and provides +12V for Presence sensor and/or relays. Note: Although the input and outputs are opto-isolated at the CiPro-7200/7400 scanner, they are single ended (referenced to Signal ground) on the Utility Box terminal strip.
10
76xx/7200/7400 Utility Interface Box
Rev E, February 2002
Page 15
Making Connections TABLE 6. TB2 Pin Out
Pin
Name
CiPro-7200/7400 function
CiMAX-76xx function
1 2
GND
Signal ground
Signal ground
+12V
Power for presence sensor, relays
Power for presence sensor, relays
3
O1
Scanner output: No Read
Output 1: No Read Led
4
O2
Scanner output: Right
Output 2: Match Led
5
O3
Scanner output: Wrong
Output 3: No Match Led
6
GND
Signal ground
Signal ground
7
I1/P+
+ Input from presence sensor (PNP)
Input 1
8
I2/P-
- Input from presence sensor (NPN)
Input 2
9
I3
Not used
Input 3
10
GND
Signal ground
Signal ground
Rev E, February 2002
76xx/7200/7400 Utility Interface Box
11
Page 16
Making Connections
Setting LED Output Jumpers The jumpers JH1, JH2, JH3 are used to connect outputs 1, 2, 3 to the LEDs respectively. These are set to OFF in the default position. The LEDs are pulled up to +12V and should be used only if no output connections are made to TB2.
Setting Presence Sensor Jumpers The jumper header J2 is used to configure the interface box for various types of input configurations. The factory default jumper positions are for a CiMAX-76xx scanner. •
For a CiPro-7200/7400 NPN presence sensor, place one shunt over pins 1 and 2, and the other shunt over pins 3 and 4. Presence will be active when a low signal is placed on the P- input.
•
For a CiPro-7200/7400 PNP presence sensor, place one shunt over pins 2 and 3, and the other shunt over pins 4 and 5. Presence will be active when a high signal is placed on the P+ input.
•
For a CiMAX-76xx scanner, place one shunt over pins 2 and 3, and the other shunt over pins 6 and 7. Inputs will be active when a low signal is placed on any of the three inputs.
12
76xx/7200/7400 Utility Interface Box
Rev E, February 2002
Page 17
Making Connections FIGURE 2. Presence Sensor Jumper Settings
Position for CiPro-7200/7400
Position for CiPro-76xx
PNP sensor
NPN sensor
J2
J2
+12 V
76xx/7200/7400 Utility Interface Box
GND +12 V
TB2
Rev E, February 2002
GND
TB2
+12 V
TB2
GND
J2
13