The text of a manual · part 4 of 5
76xx/7200/7400 Utility Interface Box User's Manual: Scanner Setup
Pages 18 to 24 of 29, from 76xx/7200/7400 Utility Interface Box User's Manual
The original document is the PDF (259 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the RVSI CiMatrix 7555A, Sick 7555A, RVSI CiMatrix 7600, RVSI CiMatrix 7655, RVSI CiMatrix 7800, Sick 7850, Siemens 7555A, Sick 7600, and 3 more models
Page 18
Scanner Setup
Scanner Setup Setting Scanner Parameters To set the CiPro-7200/7400 scanner parameters, connect a straight through type 9-pin male/female cable between the Utility Box Main DB9F and a PC serial port. Then, use the CiWINSET Windows-based program to set scanner parameters as desired. Scanning in the CiPro-7200/7400 Verifier Code The CiPro-7200/7400 scanner can scan in a code, which will be used as the Verifier code. The Utility Box provides an easy method to use this feature. The procedure requires setting parameters from CiWINSET, and installing a hardware jumper. Note: Scanning in the Verifier label saves the full scanner configuration (all parameter settings, including the scanned-in Verifier code) to the scanner’s memory (EEPROM). Make sure ALL parameters have the correct values before performing this procedure. 1.
Set the Multi label parameter to ‘Disabled.’
2.
Set the group of parameters under ‘Code 1’ (Type, Digit Number, etc.), for the Verifier label to be scanned.
14
76xx/7200/7400 Utility Interface Box
Rev E, February 2002
Page 19
Scanner Setup 3.
Set the Auxiliary Interface Mode parameter to ‘Disabled.’
4.
Set the Operating Mode parameter to any value except ‘Test’.
Note: It is recommended that you set this parameter to ‘Automatic’ (label is scanned automatically when the scan line falls on it). 5.
Set the Code Verifier parameter to ‘Enabled.’
6.
Set the Store verifier HW parameter to ‘Enabled.’
7.
Jumper the RTSAUX pin to the CTSAUX pin; do this by removing any cable connected to the AUX port and jumper pins 1 and 4 of the Utility Box DB9M plug on the Standard Utility Box.
8.
Scan the Verifier label. If the Operating Mode parameter is set to ‘Automatic’, simply present the label to the scanner.
9.
Remove the jumper, and restore any cabling previously removed.
10.
From the CiWINSET Device Control panel, press the Get button. The scanned-in Verifier label should appear in the Verifier Code Values parameter.
Rev E, February 2002
76xx/7200/7400 Utility Interface Box
15
Page 20
Scanner Setup 11.
Set the Store verifier HW parameter to ‘Disabled.’
12.
Set the Auxiliary Interface Mode parameter to the desired value.
13.
Set the Operating Mode parameter to the desired value.
14.
From the CiWINSET Device Control panel, press the RAM/EEPROM button until EEPROM is displayed, then press the Send button.
15.
Press the RAM/EEPROM button until the desired value is displayed.
16
76xx/7200/7400 Utility Interface Box
Rev E, February 2002
Page 21
Scanner Setup
Setting Up for Master/Slave Configurations Omni-directional reading systems with a single Master and up to 5 Slaves can be assembled using the Utility Boxes. Each scanner is connected to a multi-drop RS485 network via its Main port. This requires creating a 3-wire cable with multiple male DB9 connectors (one for each scanner), connecting to pins 2 (TX485+), 1 (TX485-), and 5 (GND). The DB9s are then plugged into each scanner Utility Box. The Presence inputs are jumpered together on all Utility Boxes and connected to the single Presence sensor. The Master scanner can communicate with the PC host over the AUX port of the Standard Utility Box (DB9M). Setting up a Master/Slave configuration requires setting scanner multi-drop addresses and setting software parameters. Refer to the CiPro-7200/7400 User Manuals for specific information.
Rev E, February 2002
76xx/7200/7400 Utility Interface Box
17
Page 22
Scanner Setup FIGURE 3. Master/Slave Configuration Setup
1 2 5 MAIN DB9F
1 2 5 MAIN DB9F
1 2 5 MAIN DB9F
Utility Box
Utility Box
Utility Box
DB25F TB2 DB9M AUX
SLAVE 2 Scanner
DB25F TB2 DB9M
SLAVE 1 Scanner
DB25F TB2 DB9M
AUX
Presence Sensor
18
MASTER Scanner
AUX
Host PC
76xx/7200/7400 Utility Interface Box
Rev E, February 2002
Page 23
Scanner Setup
Setting Up for Pass Through Configurations Pass through (daisy chain) mode also requires custom cabling. The first scanner in the chain is connected to the PC host via its Main port, using a straight through 9-pin male/female cable from Utility Box #1 to the PC serial port. Scanner #1 AUX port is connected to Scanner #2 Main port using a straight through cable. Scanner #2 AUX port is connected to Scanner #3 Main port using a straight through cable, and so on down the line. Each scanner has its own Presence sensor. Wire each scanner-to-scanner cable as follows: Scanner (n) AUX port (Utility Box terminal strip)
Scanner (n+1) Main port (Utility Box DB9)
TXAUX (DB9M Pin 3)
to
RX232 (DB9F pin 3)
RXAUX (DB9M Pin 2)
to
TX232 (DB9F pin 2)
GND (DB9M Pin 5)
to
GND (DB9F pin 5)
RTSAUX (DB9M Pin 4) to
CTS (DB9F pin 4)
CTSAUX (DB9M Pin 1) to
RTS (DB9F pin 1)
Rev E, February 2002
76xx/7200/7400 Utility Interface Box
19
Page 24
Scanner Setup Setting up a Pass-through configuration requires setting software parameters. Refer to the CiPro-7200/7400 User Manuals for specific information. FIGURE 4. Pass Through Configuration Setup
Host PC DB9F Utility Box #3 DB25 TB2 DB9M
DB9F
DB9F scanner #3
Utility Box #2 DB25 scanner #2
TB2 DB9M aux port
Presence Sensor
20
Presence Sensor
76xx/7200/7400 Utility Interface Box
Utility Box #1 DB25 scanner #1
TB2 DB9M aux port Presence Sensor
Rev E, February 2002