Page 57
Interface Units
Interface Unit I/O Connections Table 3–2 shows the Interface Unit I/O connections at Terminal Block TB1. Default assignments are indicated in parentheses. TABLE 3–2. Interface Unit I/O Connections - TB1
Signal
In/Out Pwr DB-25
1
Output 1 (NO READ)
9
2
Input 1 (INZONE PRESENCE)
1
3
Output 2 (MATCH)
10
4
Input 2 (OUTZONE PRESENCE)
2
5
Output 3 (NO MATCH)
11
6
Input 3 (TACHOMETER)
3
7
Output 4 (BEEPER)
12
8
Input 4 (HEIGHT SENSOR 1)
4
9
Output 5
13
10
Input 5 (HEIGHT SENSOR 2)
5
11
Output 6
14
12
Input 6 (HEIGHT SENSOR 3)
6
13
Output 7
15
14
Input 7 (HEIGHT SENSOR 4)
7
15
Output 8
16
16
Input 8 (HEIGHT SENSOR 5)
8
18
Beep
12
19
+12 VDC
19
Host DB-9
3
Controls, Connectors, & Indicators
TB1
17
20
Ground
21
+5 VDC
22
Ground
23
Ground
24
+12 VDC
24 5 20
25 26
Host TXD
3
27
Host RXD
2
Host T422+
1
28 29 30 31 32 33 34
Rev F, February 2002
CiMAX 75xxA/76xx Scanner Technical Reference Manual
3-17
Page 58
Chapter
3
Controls, Connectors, & Indicators
TABLE 3–2. Interface Unit I/O Connections - TB1 (continued)
In/Out Pwr DB-25
Host DB-9
TB1
Signal
35
Host T422-
6
36
Host R422+
7
37
Host R422-
9
39
Setup TXD
8
40
Setup RXD
4
41
+5 VDC
25
42
Laser control
17
46
Ground
21
47
Ground
22
48
Ground
23
Frame Ground
18
38
43 44 45
49 50
Expansion Board Input Connections Table 3–3 shows the Expansion Board Input connection at Terminal Block J2. TABLE 3–3. Expansion Board Input Connections
3-18
J2 Marked
Assignment
1 (INZ)
Height Input 1
2 (ANG)
Height Input 2
3 (TACH)
Height Input 3
4 (HT1)
Height Input 4
5 (HT2)
Height Input 5
6 (HT3)
Height Input 6
7 (HT4)
Height Input 7
8 (HT5)
Inzone Presence (connect to TB1-2)
9 +5V
+5V
10 GND
GND
11 CTSOUT
CTSOUT (RS-232)
12 CTSIN
CTSIN (TTL)
CiMAX 75xxA/76xx Scanner Technical Reference Manual
Rev F, February 2002
Page 59
Interface Units
Photoeye & Tachometer Connections Note: Connections shown here are for SICK Auto Ident, Inc. parts only. Use TB3, TB4 and TB5 instead of TB1 for complete opto-isolation. Refer to Table 3–2, “Interface Unit I/O Connections - TB1,” on page 3-17 for TB1 assignments.
3
Controls, Connectors, & Indicators
FIGURE 3–19. Photoeye & Tachometer Connections Brown +12V 24 Gnd
Inzone photoeye 935-0018-1
Black
23 Input 1
Blue White (not used)
2 Gnd 20
Brown
+12V 24 Gnd
Outzone photoeye 935-0018-1
Black Blue White (not used)
23 Input 2 4 Gnd 20
Brown
+12V 49
Height sensor 1 photoeye
Gnd Black Blue White (not used)
48 Input 4 8 Gnd 20
Gray/White Tachometer 950-0003-1
Brown/White Green/White
Input 3 6 +5V 45 Gnd 47
Interface Unit
Connectors on Scanner I/O Connector Panel Refer to Table 3–2, Table 3–3, and Table 3–4 for connector and signal specification for the Scanner I/O connector. TABLE 3–4. I/O Connections
Pin
Host
Set/Star
1
Host T422+
LAN+ (blue wire)
2
Host RXD
TERM DETECT
3
Host TXD
LAN- (white wire)
4
Host DTR
Ground
5
Ground
Frame Ground (cable shield)
Rev F, February 2002
CiMAX 75xxA/76xx Scanner Technical Reference Manual
3-19
Page 60
Chapter
3
Controls, Connectors, & Indicators
TABLE 3–4. I/O Connections (continued)
Pin
Host
Set/Star
6
Host T422-
Ground
7
Host R422+
TERM RXD
8
Host CTS
TERM TXD
9
Host R422-
+5 VDC, 500 mA max
I/O Connector Panel FIGURE 3–20. I/O Connector Panel - CiMAX 75xxA
Test Points
Optional Network connector
3-20
CiMAX 75xxA/76xx Scanner Technical Reference Manual
Rev F, February 2002
Page 61
Interface Units
FIGURE 3–21. I/O Connector Panel - CiMAX 7600/7650/7655
Test Points
Controls, Connectors, & Indicators
3
Host Connector Host Connections are also available on TB1 in the Standard and Hex Interface Unit and are brought to the scanner through the I/O Connections connector. The Host Connector provides an asynchronous serial I/O port that can be used to connect to a host computer or to other serial, ASCII devices (such as printer, display terminals, external keyboards, etc.). Control of data flow, baud rates, etc., are determined by parameters you can set. Refer to the Scanner Parameters Reference Guide for more information. This port can use RS-232, RS-422 or full modem protocols. Pins 2, 3, and 5 are always used for RS-232 communication. Pins 1, 5, 6, 7, and 9 are used for RS-422 communication. Your host may require using other pins or making other connections in order to send and receive data. The Host Connector contains two asynchronous serial I/O communication ports, Host and Terminal. The Host Port is used to connect the CiMAX 75xxA/76xx Scanner to a host computer or controller to transfer barcode data for processing.
Rev F, February 2002
CiMAX 75xxA/76xx Scanner Technical Reference Manual
3-21
Page 62
Chapter
3
Controls, Connectors, & Indicators
The SETUP Port is used to connect the scanner to another scanner or to a printer, display terminal or computer. Control of data flow, baud rates, communications protocols, etc., from both ports can be set by means of parameters and software jumpers (parameters 100-199, 200-299, and 495). Refer to the Scanner Parameters Reference Guide for more information. The Host port can be programmed to use either RS-232 or RS-422 conventions, or both. The SETUP port uses only RS-232.
Starnode Setup Connector The Starnode Connector allows the CiMAX 75xxA/76xx Scanner to be connected to an EIA-485 Starnode local area network (LAN). This network connection is not implemented in the Interface Unit. You must attach your network cable directly to the connector on the rear panel of the scanner. Refer to Table 3–4, “I/O Connections,” on page 3-19.
Setup Port Functionality on Starnode Connector The SETUP connector is provided as an input port for a local terminal. You can connect a CiMAX 1400 hand-held terminal, an ASCII terminal or a PC running a terminal emulation program. This port uses RS-232 conventions and runs at 9600 baud. Refer to Table 3–4, “I/O Connections,” on page 3-19. Setup connections are also available on TB1 in the Standard and Hex Interface Units and are connected to the scanner through the I/O Connections connector. A terminal can be used to display and change parameters values and run diagnostic tests. These functions are described in other chapters in this manual. Most terminals only require connection to pins 6, 7 and 8. The CiMAX 1400 terminal also uses pins 2 and 9. A cable with the necessary connections is provided with the terminal. Some terminals may require connecting to or jumpering other pins.
Optional Network Connectors - CiMAX 75xxA only A BNC coaxial connector (standard) for 10 Base 2 thinnet or an RJ-45 connector for 10 base T twisted pair is provided with an Ethernet option. A 4-pin SDS or 5-pin DeviceNet connector is provided with a CAN option. No network connections are available in the Standard or Hex Interface Units. If your scanner has the network option installed, you must attach your network cable directly to the connector on the I/O Connector panel of the scanner.
Electrical Test Points Six electrical test points, mounted on the printed circuit board, can be accessed by removing the round plug located in the upper right corner of the scanner I/O panel. Test point information is included in this manual for completeness. The test points are for use by factory personnel during setup and adjustment. The test point signals are:
MOD1 - Laser Modulation An analog input signal that can be used to compensate for the lower laser power at the beginning and end of each scan line.
3-22
CiMAX 75xxA/76xx Scanner Technical Reference Manual
Rev F, February 2002
Page 63
Interface Units
LSR1 - Laser Current A voltage which, when divided by the laser diode resistance, provides an estimate of the diode current.
ANA1 - Analog Signal The analog voltage from the detector before it is digitized. This signal is used to adjust the polarizing filter in the scanner.
Digitized bar code signals used to adjust the phase and mechanical position of the polygon mirror.
SOS1 - Start Of Scan A sync signal used when viewing waveforms on an oscilloscope.
GND1 - Ground A ground connection for equipment connected to the test points.
Rev F, February 2002
CiMAX 75xxA/76xx Scanner Technical Reference Manual
3-23
Controls, Connectors, & Indicators
3
BAR1 - Barcode Signal
Page 64
Chapter
3-24
3
Controls, Connectors, & Indicators
CiMAX 75xxA/76xx Scanner Technical Reference Manual
Rev F, February 2002