Page 7

Contents

CHAPTER 1

Overview & Maintenance

1–1

Overview 1–1 Typical Physical Setup 1-1 CiMAX 7500A/7600 Laser Scanner 1-2 CiMAX 7550A/7650 Laser Scanner 1-2 CiMAX 7555A/7655 Laser Scanner 1-3 Keysheet 1-3 Software Updates 1-3

Specifications 1–4 Scanner 1-4 Configuration 1–4 Physical 1–4 Method of Illumination 1–5 Scan Rates 1–5 Power 1–5 Construction 1–5 Environmental 1–5 LED Status Indicators 1–5 Communications 1–6 Inputs 1–6 Outputs 1–6 Basic Interface Unit 1-6 Physical 1–6 AC Power 1–7 Inputs 1–7 Outputs 1–7 Standard Interface Unit 1-7 Physical 1–7 AC Power 1–7 Inputs 1–7 Outputs 1–7 Optional Solid-State Input/Output Modules 1–7 Electro-Mechanical Output Relay 1–8 Hex Interface Unit 1-8 Physical 1–8 AC Power 1–8 Inputs 1–8 Outputs 1–8 Optional Solid-State Input/Output Modules 1–8 Electro-Mechanical Output Relay 1–9

Maintenance

Rev F, February 2002

1–9

CiMAX 75xxA/76xx Scanner Technical Reference Manual vii

Page 8

Contents CHAPTER 2

Installation & Setup

2–1

Unpacking & Inspection 2–1 Installation Checklist 2–1 Site Preparation 2-2 Physical Installation 2-2 Electrical Connections 2-3 On Site Testing 2-3 Operation Instruction 2-4 Final Approval 2-4

Site Preparation 2–4 Power 2-4 Setup 2-5 Photoeyes & Tachometer Installation 2-5 Installing the Tachometer 2–5 Mounting Presence Photoeyes 2–6 Mounting Photoeye Tree Bracket 2–6 Scanner Installation 2-7 Connecting CiMAX Scanner & Basic/Standard/Hex Interface Unit 2-7 On-Off Switch 2–7

CHAPTER 3

Controls, Connectors, & Indicators Scanner

3–1

3–1

LED Display 3-1 Setup 3–2 Presence 3–2 Decode 3–2 Xmit/Rcv 3–2 I/O 3–2 Pwr/Laser On (green) 3–2

Interface Units

3–2

Basic Interface Unit 3-2 I/O Panel Inputs & Outputs 3–4 Scanner Connection 3-4 Connection to a Host 3-5 Standard Interface Unit 3-5 Hex Interface Unit 3-5 Standard Interface Connections 3-6 AC Power 3-6 Hex Interface Connections 3-7 Control Input Connections 3-8 Interface Unit Inputs 3–8 Programmable Interface Controller Inputs 3–9 Optional Input Relay Modules 3–9 Control Output Connections 3-9 Special Inputs & Outputs 3-9 Laser Control 3–9 Beeper 3–10 Communications Inputs & Outputs 3–10 DC Power Outputs 3–10 Solid State Input & Output Circuits 3–10 viii

CiMAX 75xxA/76xx Scanner Technical Reference Manual

Rev F, February 2002

Page 9

Contents Standard Interface Unit Circuit Board 3-12 Hex Interface Unit Circuit Board 3-13 Programmable Interface Controller Board 3-14 Relays in the Interface Units 3-14 Standard Interface Unit 3–14 Hex Interface Unit 3–15 Typical Relay Wiring Examples 3-15 Interface Unit I/O Connections 3-17 Expansion Board Input Connections 3-18 Photoeye & Tachometer Connections 3-19 Connectors on Scanner I/O Connector Panel 3-19 I/O Connector Panel 3-20 Host Connector 3–21 Starnode Setup Connector 3–22 Optional Network Connectors - CiMAX 75xxA only 3–22 Electrical Test Points 3–22

CHAPTER 4

Introduction to Scanning Introduction 4–1 Reading Barcodes

4–1

4–1

The X Dimension 4-1 Measuring Barcodes 4-2 Quiet Zone 4-2 Quiet Zones for Stitching 4-3 Optical Considerations 4-3 Depth of Field 4–4 Optical Throw 4–4 Reading Range 4–4 Height of Scan 4–4 Scan Angle 4–4 Barcode Orientation 4-5 Ladder 4–5 Picket Fence 4–6 Tilt 4–7 Pitch 4–8 Skew 4–8 Number of Scans per Barcode 4-8 Presence Detection 4-9 Single Presence 4–9 Zone Presence 4–10 Gap Tracking 4-11 Additional Inputs 4–13 X & Y Coordinates 4–15 CIX Technology & Barcode Requirements 4-16 Processing Barcode Data 4-19 Data Transmission 4–19 When Output Message is Sent 4–20

Introduction to Scan Tunnel Applications 4–21 CiMAX 7800 Scanning Front/Back Boxes 4-21 CiMAX 7800 Scanning Front, Back, Top & Side Boxes 4–23

Rev F, February 2002

CiMAX 75xxA/76xx Scanner Technical Reference Manual ix

Page 10

Contents CiMAX 7850 Scanning Bottoms of Boxes Scan Tunnel Control 4–24 Interface Units 4–24 Additional Information 4–24

CHAPTER 5

Startup & Operation

4-23

5–1

Serial Communications Ports 5–1 Power Up 5-1 Status Messages 5–1 Power-Up With Factory Default Values 5–4 Power-Up After Memory Failure 5–4 Memory Error Detection, Response & Reporting 5–4 Power-Up With Customized Values 5–5 Power-Up After Automatic Reboot 5–5 User Interface - Parameters & Diagnostics 5-5 Operating Modes 5-5 Normal Mode 5–6 Setup & Diagnostic Modes 5–6 Resetting to Default Parameters 5–6 Terminal Types 5-7 Non-Intelligent ASCII Terminal 5-7 Setup Menu on the ASCII Terminal 5–7 Data Entry through Setup Menu on the ASCII Terminal 5–8 Diagnostics Menu Display on the ASCII Terminal 5–9 CiMAX 1400 Hand-Held Terminal 5-10 CiMAX 1400 Hand-Held Terminal Function Keys 5–11 Special-Use Alpha Keys on the CiMAX 1400 Hand-Held Terminal 5–11 Using the Hand-Held Terminal as a Real Time Display 5–12

CiMenu32 for Windows Utility (Optional)

5–12

CiMenu32 Features 5-13 System Requirements 5-13

CHAPTER 6

Host Commands & Downloads Introduction 6–1 Control Commands from the Host

6–1

6–1

ASCII 4 Command - Requesting a Diagnostic String 6-3 ASCII 5 Command - Requesting Status Information 6-4 Status String Digit Explanations 6–4 ASCII ; Command - Rebooting Scanner 6-7 ASCII < Command - Clearing Diagnostic Count 6-8 ASCII = Command - Enabling Relay Control Outputs 6-9 ASCII > Command - De-Energizing Relay Control Outputs 6-10 ASCII ? Command - Setup 6-11 Downloading Individual Parameters 6–11 Downloading Groups of Parameters 6–12 Uploading Groups of Parameters 6–12 Uploading All Group Setup Strings at Once 6–13 Set Time & Date Command 6–13 ASCII A or Greater Command - User Program Data 6-14 x

CiMAX 75xxA/76xx Scanner Technical Reference Manual

Rev F, February 2002

Page 11

Contents ~TOTAL~ Command 6-15 ~DATA~ Command 6-16 ~TOT00~ Command 6-17 ~!~ & ~$~ Commands 6-18 ~LASxx~ Command 6-19 ~QSNDx~, ~QGETx~ & ~QFLS~ Commands ~VER~ Command 6-21 Gap Tracking Diagnostic Commands 6-22

6-20

C Program Control Commands 6–23 Upload C Programs to the Host Computer (ASCII 91) Command 6-23 Erase C Program (ASCII 92) Command 6-23 Stop C Program (ASCII 93) Command 6-23 Suspend C Program (ASCII 94) Command 6-23 Resume C Program (ASCII 95) Command 6-24

C Programming Considerations

6–24

Compiling C Programs for Download 6-24 Installing C Programming Platform 6–24 Downloading C Programs (.sef) 6–24 Downloading C Programs via Starnode (.LAN) 6–26 Downloading .LAN Files - Starnode Asynchronous Controller MUX Interface 6–29

Data Detection by C 6–29 Polling 6-29 Event Manager 6-30

CHAPTER 7

Communication Modes

7–1

OPMODE Parameter 7–1 Scale Mode 7–2 Starnode Usage 7–2 RS-422 Mode 7–2

CHAPTER 8

Diagnostics

8–1

Introduction 8–1 Initiating Diagnostics Tests from a Terminal 8-1 Diagnostics Menu 8-2 Diagnostic Tests & Procedures 8-3 Stopping Diagnostic Tests 8–3 Read Speed Test 8–3 Read Quality Test 8–4 Read Efficiency Test 8–5 Minimum/Maximum Bar Test 8–6 Motor Speed Test 8–7 Input/Output (IOPRTS) Test 8–8 Label Position Test 8–8 Tachometer Status Test 8–9 Tachometer Calibration Procedure 8–9 Set Digital Potentiometers 8–11 Decoder Processor Test (CIDSP DIAGS) 8–12 Can Diagnostics (75xxA Only) 8–12 Exhaustive RAM Test 8–13

Rev F, February 2002

CiMAX 75xxA/76xx Scanner Technical Reference Manual xi

Page 12

Contents Flash Operating System Download 8–14 Restore Keysheet 8–17 Restore C Program 8–18 Set Clock Procedure 8–20 7555A/7655 Frequency Adjustment 8-21

Gap Tracking Diagnostics

8–22

Scanner Model Notification 8-22 Gap Tracking Parameters 8-22 Setting Up for Gap Tracking Diagnostics 8–23 Unsolicited Messages Sent to the Setup Port 8–23 Host Commands 8-24 ~TRACK~ 8–24 ~TRAKS~ 8–27 ~TRAKN~ 8–27 ~TRUNC~ 8–27 ~TIMES~ 8–27 ~TOLER~ 8–27 ~TOTAL~ 8–28 ~DATA~ 8–28 ~TOT00~ 8–29 NORMMD_RPT Data Reports & Formats 8–29 Position Accuracy Factors 8–32

CIX Troubleshooting 8–34 Host Commands 8-34 Recording 8-34 Playback 8-35

APPENDIX A

Group Setup Strings

A–1

Group Setup String Definitions A–1 Group Setup Parameter String Formats

A–2

Scanner Operation Parameters A-3 General Decoding Parameters A-3 Histogram Parameters A-3 Decode Format Parameters A-4 Match Strings Parameters A-4 Decoding Processor (DSP) Parameters A-5 DSP Autosetup Parameters A-6 Host & Terminal Port Serial Communications Parameters A-7 Lan Port Comms & Messages Parameters A-7 Digital Potentiometers (Parameters 444-459) A-8 Digital Jumpers Parameters A-8 Presence Inputs, Relay Types & Debounce Times Parameters A-9 Relay Outputs Parameters A-9 User Program Parameters A-10 User Variables Parameters A-10 Gap Tracking & Tachometer Input Parameters A-11 Height Detect Parameters A-12 Label Tracking A-12 xii

CiMAX 75xxA/76xx Scanner Technical Reference Manual

Rev F, February 2002

Page 13

Contents APPENDIX B

ASCII Equivalence

B–1

ASCII Equivalence Table B–1

APPENDIX C

Dimension Diagrams

C–1

CiMAX 7500A Scanner C–1 CiMAX 7555A Scanner C–2 CiMAX 7600 Scanner C–3 CiMAX 7650/7655 Scanner C–4 Standard Interface Unit C–5 Hex Interface Unit C–6 Basic Interface Unit C–7 Photoeye C–7 Photoeye Tree Bracket C–9 Photoeye Tree Hardware C–10 Tachometer Assembly C–11 CiMAX 1400 Hand-Held Terminal C–12

Index

Rev F, February 2002

Index–1

CiMAX 75xxA/76xx Scanner Technical Reference Manual xiii

Page 14

Contents xiv

CiMAX 75xxA/76xx Scanner Technical Reference Manual

Rev F, February 2002