The text of a manual · part 22 of 23
CiMAX 75xxA/76xx Scanner Technical Reference Manual: APPENDIX C Dimension Diagrams
Pages 191 to 202 of 206, from CiMAX 75xxA/76xx Scanner Technical Reference Manual
The original document is the PDF (3.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the RVSI CiMatrix 7500, RVSI CiMatrix 7555A, Sick 7555A, RVSI CiMatrix 7600, RVSI CiMatrix 7655, Siemens 7500, Siemens 7555A, Sick 7600, and 2 more models
Page 191
C Dimension Diagrams
APPENDIX C
Dimension Diagrams
C CiMAX 7500A Scanner FIGURE C–1. CiMAX 7500A Scanner
Rev F, February 2002
CiMAX 75xxA/76xx Scanner Technical Reference Manual
C-1
Page 192
Appendix
C
Dimension Diagrams
CiMAX 7555A Scanner
3.05
FIGURE C–2. CiMAX 7555A Scanner
4.11
[76.20mm] 3.00 MINIMUM AREA FOR CABLE ACCESS
[173.99mm] 6.85
[121.51mm] 4.78 [49.62mm] 1.954
[144.78mm] 5.70
[72.21mm] 2.84
CAPTIVE BOLTS 1/4-20 UNF x 1.00 Lg. 2 SUPPLIED
C-2
[140.33mm] 5.52 MAX ADJUSTABLE
CiMAX 75xxA/76xx Scanner Technical Reference Manual
[54.58mm] 2.15
Rev F, February 2002
Page 193
CiMAX 7600 Scanner
CiMAX 7600 Scanner FIGURE C–3. CiMAX 7600 Scanner
Dimension Diagrams
C
Rev F, February 2002
CiMAX 75xxA/76xx Scanner Technical Reference Manual
C-3
Page 194
Appendix
C
Dimension Diagrams
CiMAX 7650/7655 Scanner FIGURE C–4. CiMAX 7650/7655 Scanner
[76.20] 3.00 Min. Area for Cable Access
[96.14] 3.78
[173.99] 6.85
[144.78] 5.70
Captive Bolts 1/4-28 UNF x 1.00 Lg. 2 Supplied
C-4
[140.33] 5.52 Max Adjustable
CiMAX 75xxA/76xx Scanner Technical Reference Manual
[29.20] 1.15
Rev F, February 2002
Page 195
Standard Interface Unit
Standard Interface Unit FIGURE C–5. Standard Interface Unit Dimensions
Dimension Diagrams
C
Rev F, February 2002
CiMAX 75xxA/76xx Scanner Technical Reference Manual
C-5
Page 196
Appendix
C
Dimension Diagrams
Hex Interface Unit FIGURE C–6. Hex Interface Unit Dimensions ALTERNATE HINGE SIDE ‘F’ ‘E’ ‘D’ o1.75” KNOCKOUTS FOR CABLE ENTRY 6 PLC’S
‘C’ ‘B’ 20.5”
‘A’
19.5”
HINGE SIDE
4.21” 2” 2.61”
9”
2”
2” 2” o.44” MOUNTING HOLE (12 PLC’S)
CABLE (25 FT MAX) CONNECT TO SCANNER
C-6
CiMAX 75xxA/76xx Scanner Technical Reference Manual
Rev F, February 2002
Page 197
Basic Interface Unit
Basic Interface Unit FIGURE C–7. Basic Interface Unit Dimensions
Dimension Diagrams
C
Photoeye The 935-0018-1 photoeye is a compact, self contained photo-electric sensor. The photoeye unit includes a control system, a power supply, an optical emitter, a receiver, and a cable for input/output connections. The retro-reflective target is a polarized sensor. The photoeye will not receive a false signal from an object or background which is highly reflective but will only read a light beam reflected by the target. A rear-mounted LED close to the connector cable lights when the photoeye does not receive the reflected beam, indicating that an object has been detected.
Rev F, February 2002
CiMAX 75xxA/76xx Scanner Technical Reference Manual
C-7
Page 198
Appendix
C
Dimension Diagrams
FIGURE C–8. End views of Photoeye
FIGURE C–9. Photoeye Dimensions
C-8
CiMAX 75xxA/76xx Scanner Technical Reference Manual
Rev F, February 2002
Page 199
Photoeye Tree Bracket
Photoeye Tree Bracket FIGURE C–10. Photoeye Tree Bracket & Dimensions
Dimension Diagrams
C
Rev F, February 2002
CiMAX 75xxA/76xx Scanner Technical Reference Manual
C-9
Page 200
Appendix
C
Dimension Diagrams
Photoeye Tree Hardware FIGURE C–11. Photoeye Tree Hardware and Part Numbers
Attach to Conveyor or Mount on Floor
A1-62887 Photoeye Bracket with 8-32 Hardware
A1-62876 Pipe Flange Assembly with 1/4-2D Hardware
A1-62886 U-Bolt Assembly
A4-62059-1 (short) A4-62059-4 (long) Mounting Pipe
C-10
922-0014-1 Pipe Fitting
A4-62874 Pipe Flange Mounting Bracket
A4-60888 Floor Plate
CiMAX 75xxA/76xx Scanner Technical Reference Manual
Rev F, February 2002
Page 201
Tachometer Assembly
Tachometer Assembly FIGURE C–12. Tachometer Assembly
H25 D
MECHANICAL
MS3102R18-1P Connector
Shaft Diameter: .3745 in. diameter standard SM Connector Optional Flat On Shaft: .80 long x .03 deep Position Shaft Loading: up to 40 lbs. axial & 35 lbs. radial Shaft Runout: .0005 T.I.R. at midpoint o Starting Torque & 25 C (STD, without shaft seal): 1.0 in-oz. maximum
1.65 (SM 18)
Bearings: Shaft: Housing & Cover: Bearing Life: 2.50 Moment of Inertia: Weight:
Class ABEC 7 416 Stainless Steel Die cast aluminum 2x108 revs at rated shaft loading. 10x109 revs at 10% of rated shaft loading. (Mfr’s Specs) 4.1 x 10-4 oz-in-sec2 13 oz. typical
2.52 DIA. MAX
ELECTRICAL
.275 .300
.85 .3745 DIA. 1.2495 DIA. 2.064 TYP
.21 R
Code: Cycles Per Shaft Turn: Supply Voltage:
Incremental 1 to 2540 on code disc +5Vdc +5% standard, optional higher voltages available
Current Requirements: TTL: 175mA max. 125mA typical CMOS: 120mA max. 100mA typical Output Format: 2 channels (A & B) in quadrature +270 electrical Output Format Options: Index & complementary outputs are available Illumination: LED Frequency Response: 100kHz
1.032 Manufacturer: BEI
2.650 Square
.218 DIA. 4 Holes (2.919 DIA B.C REF)
MODEL NUMBER: H25D-(blank)-(blank)-300-ABZ C-7406R-LED-S-M18
Rev F, February 2002
CiMAX 75xxA/76xx Scanner Technical Reference Manual
C-11
C Dimension Diagrams
Square Flange
Page 202
Appendix
C
Dimension Diagrams
CiMAX 1400 Hand-Held Terminal FIGURE C–13. CiMAX 1400 Hand-Held Terminal
C-12
CiMAX 75xxA/76xx Scanner Technical Reference Manual
Rev F, February 2002