Manual · Sick
MHI-2000 Technical Reference Manual
Manual207 pagesPDF 2.6 MB
Technical reference manual for the SICK MHI-2000: specifications, installation, connectors, startup, host commands and diagnostics.
Covers · 1 model
The models it covers
Summary
What is in it
The SICK Auto Ident technical reference manual for the MHI-2000, a unit used with equipment such as photoeyes and a tachometer. It gives specifications and maintenance, installation and site preparation including tachometer and photoeye mounting, the I/O panel, LEDs, input and output connections and front-panel connectors, power up and operating modes, host commands and downloads, and diagnostics, with appendices of group setup strings and ASCII equivalents.
Its parts
- Overview & Maintenance
- Installation & Setup
- Controls, Connectors, & Indicators
- Startup & Operation
- Host Commands & Downloads
- Diagnostics
From the manual
Key facts from this manual
Each line names its page in the PDF.
The SICK Auto Ident MHI-2000 Technical Reference Manual (EM-63555-1A, Rev A, January 2002) for the MHI-2000, a unit that works with photoeyes and a tachometer to track boxes on a conveyor and report bar code reads. It covers specifications, maintenance, photoeye and tachometer installation, the I/O panel and interface board wiring, startup and operating modes, host commands, diagnostics, dimension diagrams, modem installation and the parameter list.
- Device
- Unit that reports bar code reads, I/O status and bar code quality, using photoeyes and a tachometer for gap tracking p. 19, 25, 45
- Communications
- Six ports: RS-232 Host, Terminal/Slave, Setup and D-port; RS-485 LAN with Starnode protocol; Ethernet 10 base T p. 21
- Power input
- 115/230 +/-10% VAC @ 2.0/1.0 A, 50/60 Hz, automatic selection; fuse 3A, 250 VAC, 3AG type p. 20, 27
- DC power out
- +12 VDC, 750 mA to photocells, tachometer, etc.; +5 VDC, 375 mA to tachometer p. 20
- Memory
- 2M, about 800K of it for user C programs and data; flash memory for field re-programming p. 19, 20
- Inputs
- Eight, active low below 1.0 VDC; maximum 30 VDC intermittent, 27 VDC continuous p. 21
- Outputs
- Eight, open collector solid state, 30 VDC at 150 mA max. p. 21
- Optional I/O modules
- Two Opto-22 style modules: IDC15 DC input (10-32 VDC), ODC15 DC output (5-60 VDC), IAC15/OAC15 AC (90-140 VAC), IAC15A/OAC15A AC (180-280 VAC) p. 20
- Size and weight
- 10.75 x 6.5 x 5 inches (273 x 165.1 x 127 mm); 5.5 pounds (2.5 kilograms) p. 20
- Environment
- Gasketed aluminum enclosure, dust-tight and drip-proof; 32° to 122° F (0° to 50° C); humidity 5% to 95% non-condensing p. 21
- Terminal blocks
- TB1 to TB8, one per channel: pin 1 GND, 2 input, 3 +12V, 4 GND, 5 output, 6 +5V; TB14 and TB15 serve Opto-22 modules K1 and K2 p. 31, 32
- Tachometer
- Travel resolution finer than 0.20 inches per pulse at no more than 1 kHz; measuring wheel P/N 16002070215 and mounting base P/N 14005750000 p. 25
- Modem kit
- 56k Data/Fax Modem 971-0165-1; scanner-modem cable (9 to 25 pin) A1-62785-4; Velcro mounting pad A4-66312-2 p. 117
- Photoeye tree parts
- A1-62887 photoeye bracket, A1-62876 pipe flange assembly, A1-62886 U-bolt assembly, A4-62059-1 (short) and A4-62059-4 (long) mounting pipe, A4-60888 floor plate p. 114
What this manual walks you through
- Monthly cleaning and inspection p. 22
- Installing the tachometer on the conveyor p. 25, 26
- Mounting presence and height-detecting photoeyes p. 26
- Reading the ten status LEDs p. 27, 28, 29
- Wiring inputs, outputs and Opto-22 relay modules on the interface board p. 31, 32, 33, 34
- Power-up messages and boot commands on the Setup port p. 43, 44, 45
- Entering Diagnostics mode and running the I/O and tachometer tests p. 85, 86, 87
- Calibrating the tachometer to set the conveyor speed parameter p. 88
- Installing a modem for remote diagnostics p. 117
Good to know
- The internal parts need no maintenance, and opening the unit with power applied can cause injury. p. 22
- Commands typed through the serial ports must be in uppercase. p. 85
- Setting parameter 702 FIXED CONV SPEED to zero disables gap tracking. p. 88
- The tachometer needs a flexible coupling or belt drive; without that isolation its bearings wear. p. 25
- The REC DATA and XMIT DATA LEDs do not monitor the Ethernet port. p. 28
Questions this manual answers
How do I enter diagnostics mode on the MHI-2000?
Type ~?D~ in uppercase from an ASCII terminal or terminal emulator, or on a CiMAX 1400 hand-held terminal press Shift, release it, and press F2. p. 85
What fuse does the MHI-2000 use?
A 3A, 250 VAC, 3AG fuse, in the compartment above the power switch. p. 27
What does the red DIAGS LED on the MHI-2000 mean?
A serious memory problem or another fatal error the software can detect; the diagnostics software shows the exact reason. p. 28
What power does the MHI-2000 need?
115/230 VAC +/-10%, 50/60 Hz, at 2.0/1.0 A; the supply selects the voltage automatically. p. 20, 27
What tachometer does the MHI-2000 need for gap tracking?
One giving conveyor travel finer than 0.20 inches per pulse at a pulse rate of no more than 1 kHz. p. 25
Contents
Chapters and sections
Each line opens the PDF at its page.
- MHI-2000 Technical Reference Manual1
- CHAPTER 1 Overview & Maintenance19
- CHAPTER 2 Installation & Setup23
- CHAPTER 3 Controls, Connectors, & Indicators27
- CHAPTER 4 Startup & Operation43
- CHAPTER 5 Host Commands & Downloads53
- CHAPTER 6 Diagnostics85
- APPENDIX A Group Setup Strings97
- APPENDIX B ASCII Equivalence107
- APPENDIX C Dimension Diagrams111
- APPENDIX D Modem Installation117
- APPENDIX E Parameters121
The whole text · 25 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- MHI-2000 Technical Reference Manual, pages 1 to 91-9
- MHI-2000 Technical Reference Manual, pages 10 to 1810-18
- CHAPTER 1 Overview & Maintenance19-22
- CHAPTER 2 Installation & Setup23-26
- CHAPTER 3 Controls, Connectors, & Indicators, pages 27 to 3427-34
- CHAPTER 3 Controls, Connectors, & Indicators, pages 35 to 4235-42
- CHAPTER 4 Startup & Operation43-52
- CHAPTER 5 Host Commands & Downloads, pages 53 to 6053-60
- CHAPTER 5 Host Commands & Downloads, pages 61 to 6861-68
- CHAPTER 5 Host Commands & Downloads, pages 69 to 7669-76
- CHAPTER 5 Host Commands & Downloads, pages 77 to 8477-84
- CHAPTER 6 Diagnostics85-96
- APPENDIX A Group Setup Strings97-106
- APPENDIX B ASCII Equivalence107-110
- APPENDIX C Dimension Diagrams111-116
- APPENDIX D Modem Installation117-120
- APPENDIX E Parameters, pages 121 to 130121-130
- APPENDIX E Parameters, pages 131 to 140131-140
- APPENDIX E Parameters, pages 141 to 150141-150
- APPENDIX E Parameters, pages 151 to 160151-160
- APPENDIX E Parameters, pages 161 to 170161-170
- APPENDIX E Parameters, pages 171 to 180171-180
- APPENDIX E Parameters, pages 181 to 190181-190
- APPENDIX E Parameters, pages 191 to 200191-200
- Index201-207
The file