MHI-2000 Technical Reference Manual: APPENDIX E Parameters, pages 171 to 180

Pages 171 to 180 of 207, from MHI-2000 Technical Reference Manual

The original document is the PDF (2.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Sick MHI2000

Page 171

640 - 697 Ethernet Network Parameters

640 - 697 Ethernet Network Parameters 640 650

NETWORK NAME 1 NETWORK NAME 2 NETWORK NAME x Valid Values

ASCII string up to 20 characters

Default Value

None

Description

This string parameter is provided so that a character based network name can be associated with a given Ethernet connection.

Parameters

E

Rev A, January 2002

MHI-2000 Technical Reference Manual

E-51

Page 172

Appendix

641 651

E

Parameters

IP ADDRESS 1 IP ADDRESS 2 IP ADDRESS x Valid Values

X.X.X.X (where X = 0 - 255)

Default Value

IP ADDRESS 1, 10.6.1.210 IP ADDRESS 2, 000.000.000.000

Description

E-52

The device provides for up to two Ethernet hardware connections. Network 1 is the on board Ethernet connection and Network 2 is the optional add on Ethernet card. The IP Address parameters define the desired TCP/IP address for each connection.

MHI-2000 Technical Reference Manual

Rev A, January 2002

Page 173

640 - 697 Ethernet Network Parameters

642 652

SUBNET MASK 1 SUBNET MASK 2 SUBNET MASK x Valid Values

X.X.X.X (where X = 0 - 255)

Default Value

255.255.255.000

Description

If a device system is connected to a network that is already using a subnet mask, all of the devices in the system should use the same subnet mask. Otherwise, the subnet mask should match the default for the class of network address being used. The string nosubnet can be used to specify no subnetting. The default of 255.255.255.000 is for a class C network address.

Parameters

E

Rev A, January 2002

MHI-2000 Technical Reference Manual

E-53

Page 174

Appendix

643 653

E

Parameters

GATEWAY 1 GATEWAY 2 GATEWAY x Valid Values

X.X.X.X (where X = 0 - 255)

Default Value

GATEWAY 1, 10.6.1.1 GATEWAY 2, 000.000.000.000

Description

E-54

If routing is not used, the default gateway address 000.000.000.000 should be used, otherwise, the desired Gateway address is defined here.

MHI-2000 Technical Reference Manual

Rev A, January 2002

Page 175

640 - 697 Ethernet Network Parameters

645 655

BROADCAST 1 BROADCAST 2 BROADCAST x Valid Values

0 or 1

Default Value

1

Description

Under the BSD 4.2 release of TCP/IP, a destination address of all zeros was used as a broadcast address. Under the BSD 4.3 release, this was changed to all ones. Either can be used. 0 invokes BSD 4.2 1 invokes BSD 4.3

Parameters

E

Rev A, January 2002

MHI-2000 Technical Reference Manual

E-55

Page 176

Appendix

646 656

E

Parameters

CONTROLLER OPTS 1 CONTROLLER OPTS 2 CONTROLLER OPTS x Valid Values

0 - 255

Default Value

000

Description

This parameter is a bitmap of the following selections. TABLE E–18. Values and Descriptions

Value

Description

000

10 Base 2

001

Use twisted pair

002

Set squelch level to 240mV (default of 400 mV is recommended)

004

Full step mode for BNC (1/2 step is recommended)

008

Disable link testing for twisted pair (Enabled is recommended)

255

Use the Ethernet adaptor jumper settings.

Note: The device supports RJ-45 twisted pair (10 Base T) cabling as options for the add on Ethernet card only.

E-56

MHI-2000 Technical Reference Manual

Rev A, January 2002

Page 177

640 - 697 Ethernet Network Parameters

647 657

HARDWARE ADDRESS 1 HARDWARE ADDRESS 2 ETHERNET ADAPTER ADDRESS x Valid Values

00:20:5a:xx:xx:xx (where xx = hardware address)

Default Value

00:20:5a:xx:xx:xx

Description

This parameter is read only. The Ethernet address assigned to the device will be displayed. If no Ethernet controller is found by the device, or if an error occurs retrieving the Ethernet address, then NONE will be displayed. A typical Ethernet address is 00:20:5a, where 00:20:5a is the SICK Auto Ident, Inc. address. This address is assigned by IEEE to adapters that are manufactured by SICK Auto Ident, Inc.

Parameters

E

Rev A, January 2002

MHI-2000 Technical Reference Manual

E-57

Page 178

Appendix

660

E

Parameters

FTP IP ADDRESS FTP IP ADDRESS

E-58

Valid Values

X.X.X.X (where X = 0 - 255)

Default Value

10.6.1.16

Description

This string provides the TCP/IP address assigned to an FTP server that may be used to transfer a new O/S to the MHI-2000. To initiate the O/S transfer, run diagnostics and select the O/S upgrade menu option. The FTP connection is associated with the on-board Ethernet circuit.

MHI-2000 Technical Reference Manual

Rev A, January 2002

Page 179

640 - 697 Ethernet Network Parameters

661 662

FTP LOGIN NAME FTP LOGIN PASSWORD FTP LOGIN NAME and PASSWORD Valid Values

ASCII string up to 15 characters

Default Value

FTP LOGIN NAME, operations FTP LOGIN PASSWORD, cimatrix

Description

These strings provide the login name and login password to be used when logging into an FTP server. An FTP server may be used to transfer a new O/S to the MHI-2000. To initiate the O/S transfer, run diagnostics and select the O/S upgrade menu option.

Parameters

E

Rev A, January 2002

MHI-2000 Technical Reference Manual

E-59

Page 180

Appendix

663 664

E

Parameters

NETWORK LOGIN NAME NETWORK LOGIN PASSWORD NETWORK LOGIN NAME and PASSWORD Valid Values

ASCII string up to 15 characters

Default Value

NETWORK LOGIN NAME, cimatrix NETWORK LOGIN PASSWORD, cimatrix

Description

E-60

These strings provide a login name and password for the on-board Ethernet connection. They provide a string-based method of identifying various scanners when multiple scanners are located on a network.

MHI-2000 Technical Reference Manual

Rev A, January 2002