Page 27
3 Controls, Connectors, & Indicators
CHAPTER 3
This chapter describes the physical layout, controls, connectors and indicators on the MHI-2000.
MHI-2000 I/O Panel The I/O panel on the MHI-2000 contains all indicators, controls, and connectors, as shown in Figure 3–1. FIGURE 3–1. I/O Panel
Power Input/ON-OFF Switch/Fuse Unit Connect a standard power cord to the AC input connector. The power supply accepts either 115 or 230 VAC, with internal automatic selection. The input cable should be clamped to the connector for maximum security. The power ON/OFF (I/0) rocker switch is located above the AC input connector. Press I to turn the MHI-2000 ON; press 0 to turn the MHI-2000 OFF. The fuse compartment is located above the Power Switch. The fuse is a 3A, 250 VAC, 3AG type. To verify the fuse type, carefully open the fuse compartment with a small screwdriver.
Status Indicators There are 10 LED status indicators on the I/O panel of the MHI-2000. The LED colors and function names are shown in Figure 3–2.
Rev A, January 2002
MHI-2000 Technical Reference Manual
3-1
Controls, Connectors, & Indicators
3
Page 28
Chapter
3
Controls, Connectors, & Indicators
FIGURE 3–2. LED Display
Yellow
Yellow
Yellow
Yellow
Yellow
Green
INPUTS
OUTPUTS
DECODE
SET-UP
POWER ON
REC DATA
Green
PRESENCE 2
DIAGS.
Yellow
PRESENCE 1
Green
XMIT DATA
Red
LEDs Diags The DIAGS. LED lights whenever one or more of the following conditions occur in the MHI-2000: •
A serious problem with the computer system memory has occurred.
•
Other types of fatal errors have occurred that are detectable by the software.
Because the diagnostics indicator is shared, you may have to run the diagnostics software to determine the precise reason that the LED is ON.
Rec Data The REC DATA LED blinks whenever the MHI-2000 receives characters from the Host, Terminal, Setup and Starnode ports. The Ethernet port is not monitored. This LED helps to verify wiring and assure that those communication signals are reaching the MHI-2000.
Xmit Data The XMIT DATA LED blinks whenever the MHI-2000 transmits characters to the Host, Terminal, Setup, and Starnode ports. The Ethernet port is not monitored. This LED indicates that the MHI2000 is sending data from a communication port.
Presence 1 The PRESENCE 1 LED displays the status of the signal from the INZONE photoeye. The PRESENCE 1 LED monitors INPUT 1 of the MHI-2000.
Presence 2 The PRESENCE 2 LED displays the status of the signal from the OUTZONE photoeye. The PRESENCE 2 LED monitors INPUT 2 of the MHI-2000.
Inputs The INPUTS LED displays the state of all standard inputs (1 - 8) combined. When any of the inputs is enabled, the LED will light. To determine the status of each input individually, you must run the INPUTS test of the diagnostics program.
3-2
MHI-2000 Technical Reference Manual
Rev A, January 2002
Page 29
MHI-2000 I/O Panel
When OPTO-22 relays are installed in the Interface Board, you can determine which input relays are active by observing the LED associated with each relay. The inputs on the optional Programmable Interface Controller are not monitored.
Outputs
When output relays are installed in the Interface Board, you can determine which output relays are active by observing the LED associated with each relay.
Decode The DECODE LED has no function currently.
Set-Up The SET-UP LED indicates that the MHI-2000 is in either the Setup or Diagnostics mode. Therefore, it is not running your custom application software.
Power On The POWER ON LED indicates that MHI-2000 power is ON. When power is applied, the computer performs internal diagnostic tests.
Interface Board Connections The Interface Board is accessible by removing the MHI-2000 cover. The MHI-2000 Command and Control Board provides 12VDC and 5VDC power to operate the Interface Board. There are two jumpers, internal to the MHI-2000, to connect DC output power to the interface board. This is done by moving shunts of JH10 (1-2) and JH11 (1-2) on the Command and Control Board. This is the default setting. All control and communication I/O connections, except to networks, should be made at the Interface Board. Connect network cables, if used, directly to the MHI-2000. You can also connect a terminal to the SETUP connector on the front panel of the MHI-2000, although, normally, it will be more convenient to make the connection at the Interface Board.
Rev A, January 2002
MHI-2000 Technical Reference Manual
3-3
3
Controls, Connectors, & Indicators
The OUTPUTS LED displays the state of all outputs (1 - 8) combined. When any of the outputs is enabled, the LED will light. To determine the status of each output individually, you must run the OUTPUTS test of the diagnostics program.
Page 30
Chapter
3
Controls, Connectors, & Indicators
FIGURE 3–3. Standard Interface Unit Circuit Board
3-4
MHI-2000 Technical Reference Manual
Rev A, January 2002
Page 31
MHI-2000 I/O Panel
TABLE 3–1. Interface Board I/O Connections
GND
GROUND
TB1-2
IN1
INPUT 1
TB1-3
+12V
+12V POWER
TB1-4
GND
GROUND
TB1-5
OUT1
OUTPUT 1
TB1-6
+5V
+5V POWER
TB2-1
GND
GROUND
TB2-2
IN2
INPUT 2
TB2-3
+12V
+12V POWER
TB2-4
GND
GROUND
TB2-5
OUT2
OUTPUT 2
TB2-6
+5V
+5V POWER
TB3-1
GND
GROUND
TB3-2
IN3
INPUT 3
TB3-3
+12V
+12V POWER
TB3-4
GND
GROUND
TB3-5
OUT3
OUTPUT 3
TB3-6
+5V
+5V POWER
TB4-1
GND
GROUND
TB4-2
IN4
INPUT 4
TB4-3
+12V
+12V POWER
TB4-4
GND
GROUND
TB4-5
OUT4
OUTPUT 4
TB4-6
+5V
+5V POWER
TB5-1
GND
GROUND
TB5-2
IN5
INPUT 5
TB5-3
+12V
+12V POWER
TB5-4
GND
GROUND
TB5-5
OUT5
OUTPUT 5
TB5-6
+5V
+5V POWER
TB6-1
GND
GROUND
TB6-2
IN6
INPUT 6
TB6-3
+12V
+12V POWER
Rev A, January 2002
MHI-2000 Technical Reference Manual
3
Controls, Connectors, & Indicators
TB1-1
3-5
Page 32
Chapter
3
Controls, Connectors, & Indicators
TABLE 3–1. Interface Board I/O Connections (Continued)
TB6-4
GND
GROUND
TB6-5
OUT6
OUTPUT 6
TB6-6
+5V
+5V POWER
TB7-1
GND
GROUND
TB7-2
IN7
INPUT 7
TB7-3
+12V
+12V POWER
TB7-4
GND
GROUND
TB7-5
OUT7
OUTPUT 7
TB7-6
+5V
+5V POWER
TB8-1
GND
GROUND
TB8-2
IN8
INPUT 8
TB8-3
+12V
+12V POWER
TB8-4
GND
GROUND
TB8-5
OUT8
OUTPUT 8
TB8-6
+5V
+5V POWER
TB14-1
K1-1
K1 OPTO-22 PIN 1
TB14-2
K1-2
K1 OPTO-22 PIN 2
TB14-3
I/O1
K1 OPTO-22 INPUT or OUTPUT
TB15-1
K2-1
K2 OPTO-22 PIN 1
TB15-2
K2-2
K2 OPTO-22 PIN 2
TB15-3
I/O2
K2 OPTO-22 INPUT or OUTPUT
Control Input Connections Interface Unit Inputs All eight standard solid-state control input connections to the Interface Board are available at terminal block TB1 through TB8, as shown in Figure 3–3, “Standard Interface Unit Circuit Board” on page 3-4. Connector assignments are listed in Table 3–1, “Interface Board I/O Connections” on page 3-5.
3-6
MHI-2000 Technical Reference Manual
Rev A, January 2002
Page 33
MHI-2000 I/O Panel
FIGURE 3–4. Typical Solid-State Input Circuit
+12 VDC
3.3K Ohms
ULN2003
3
0.1 mf
Maximum input voltage 30 VDC, 27 VDC continuous
Optional Input Relay Modules Two optional solid-state input relay modules (OPTO22) may be used to accommodate AC/DC input and output signals. Input relay modules can be plugged into locations K1 or K2. Relay modules with several different AC and DC voltage and power ratings can be provided to fit your application. External wiring should be connected to TB14/15 pins 1/2 respectively, as shown in Figure 3–5. An additional 22 AWG is required to complete the connection to the specific input you require. Connect this wire from TB14/15 pin3 to required input TB1-8 pin2. FIGURE 3–5. Solid-State Input Relay Module
TB14,TB15
TB14,TB15
Divert Control Relay
K1 Add Wire to MHI-2000 Specified Input TB1-TB8
K1 -1
IN_OUT
Divert Gate
Solid state input relay module (IAC15)
Divert Gate Power
K1 -2
Interface Unit
Control Output Connections Interface Unit Outputs All eight standard solid-state control output connections to the Interface Board are available at terminal block TB1 through TB8, as shown in Figure 3–3, “Standard Interface Unit Circuit Board” on page 3-4. Connector assignments are listed in Table 3–1, “Interface Board I/O Connections” on page 3-5.
Rev A, January 2002
MHI-2000 Technical Reference Manual
3-7
Controls, Connectors, & Indicators
Input active low when input < 1.0 volts
Page 34
Chapter
3
Controls, Connectors, & Indicators
FIGURE 3–6. Typical Solid-State Output Circuit
Open collector output limits: 30 Volts at 150 mA max
MHI-2000
Optional Output Relay Modules Two optional solid-state output relay modules (OPTO22) may be used to accommodate AC/DC input and output signals. Output relay modules can be plugged into locations K1 or K2. Relay modules with several different AC and DC voltage and power ratings can be provided to fit your application. External wiring should be connected to TB14/15 pins 1/2 respectively, as shown in Figure 3–7. An additional 22 AWG is required to complete the connection to the specific output you require. Connect this wire from TB14/15 pin3 to required output TB1-8 pin5. FIGURE 3–7. Solid-State Output Relay +12 VDC
TB14,TB15 Line
3.0K
Solid state Output relay module (OAC12)
K1
K1 -1
K1 -2
Hot Divert Gate Power
Load Divert Gate
Neutral
Interface Unit
MHI-2000
3-8
MHI-2000 Technical Reference Manual
Rev A, January 2002